Loading...
Wynnpage Plaza-LR021119CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021373.0011 Service Date: November 11,2002 Client: Pacific Builders Inc Attn: Charles Coleman 3360 Wiley Post Rd Ste 100 Carrollton TX 75006 Report Date: Project: Wynnpage 255 Denton Tap Coppell, TX 'll'erracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 November 19, 2002 Project Number: 94021373 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: 9:25am Supplier: Hanson Truck No: 924 Mix I.D. No.: 9351 Plant: 27 Ticket No: 290011 Sample Information Sample Time: 10:00am Date Cast: November 11,2002 Technician: Barry M. Cuble Weather Conditions: Sunny, mild Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: 10' S of N curb, 10' E of W curb, W side Placement Location: Paving: W & E parking Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result Specification Test Method 3.75 3-5 ASTM C-143 8.5 3-6' ASTM C-231 70 ASTM C1064 57 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 11/18/2002 7 93,000 3,290 1 2 6.00 28.27 11/18/2002 7 92,830 3,280 Average 3,290 1 3 12/09/2002 28 1 4 12/09/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Barry M. Cuble Repod Distribution: (1) Pacific Builders Inc (1) City of Coppeli Engineering Reviewed by: HBCfTerracon Hussein H. Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical Page 1 of 1