Amberpoint BP 2-LR030110 cONCRETE COMPRESSIVE STRENGTH TEST . Report Number: 94021380.0177 Service Date: January 2, 2003 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 'll'erracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: January 10, 2003 Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 7:34am Plant: 1 Supplier: Potter Concrete Truck No: 110 Mix I.D. No.: 9385 Water Added Onsite Before Test: 15 Gallons Ticket No: 12942 Sample Information Sample Time: 8:20am Date Cast: January 2, 2003 Technician: Jose A. Martinez Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Pump Sample Locations: From top of panel 141 & 10' down Placement Location: Panels 141 to 136/112 to 108, 67 to 74 & 38 to 41 Note: Concrete daily report attached. Field Test Data Test Result Specification Test Method 4.50 4-5 ASTM C-143 1.7 N/A ASTM C-231 57 55 - 95 ASTM C1064 40 ASTM C-1064 Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test · Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 6.00 28.27 01/09/2003 7 162,450 5,740 6.00 28.27 01/09/2003 7 156,640 5,540 Average 5,640 01/30/2003 28 01/30/2003 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propedies of other apparently similar or identical materials. Page 1 of 6 0~-~LW~.O~-~.K.y coNCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0177 Service Date: January 2, 2003 'll'erracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: January 10, 2003 Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 9:32am Plant: 1 Supplier: Potter Concrete Truck No: 110 Mix I.D. No.: 9385 Ticket No: 12953 Sample Information Sample Time: 9:50am Date Cast: January 2, 2003 Technician: Jose A. Martinez Weather Conditions: Clear, windy Accumulative Yards: Placement Method: Sample Locations: Placement Location: 110 Pump See placement location See page 1 Sample location: 3' E side of panel 36 & 37 from top to bottom Field Test Data Test Result Slump, inches: 5.50 Air Content, %: 1.6 Concrete Temperature, o F: 56 Ambient Temperature, o F: 56 Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 2 1 6.00 28.27 2 2 6.00 2827 2 3 6.00 28.27 2 4 6.OO 28.27 2 5 Specification 4-5 N/A 55 - 95 Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 01/05/2003 3 120,580 4,260 01/05/2003 3 128,910 4,560 Average 4,410 01/09/2003 7 162,690 5,750 01/09/2003 7 156,190 5,520 Average 5,640 01/30/2003 28 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 6 01'LL~'YRO1-F~m'KeY CONCRETE COMPRESSIVE STRENGTH TEST Client: Transwestern Commercial Services 'lrerracon Project Number: 94021380 Report Number: 94021380.0177 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 6 01/30/2003 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 6 O,-LL~,~-F,,.,.~.y cONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0177 Service Date: January 2, 2003 ']rerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: January 10, 2003 Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 Material Information Specified Strength: 3500 psi @ 28 Days BatchTime: 11:12am Plant: 1 Supplier: Potter Concrete Truck No: 113 Mix I.D. No.: 9385 Water Added Onsite Before Test: Ticket No: 12963 5 Gallons Sample Information Sample Time: 11:32am Date Cast: January 2, 2003 Technician: Jose A. Martinez Weather Conditions: Clear, light winds Accumulative Yards: 210 Placement Method: Pump Sample Locations: See placement location Placement Location: See page 1 Sample location: W side of panel 110 & 4' E from top to bottom Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.25 1,4 64 54 Specification Test Method 4-5 ASTM C-143 N/A ASTM C-231 55 - 95 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (.sq. inches) Tested (days) (tbs) (psi) 3 1 6.00 28.27 01/09/2003 7 168,870 5,970 3 2 6.00 28.27 01/09/2003 7 159,510 5,640 Average 5,810 3 3 01/30/2003 28 3 4 01/30/2003 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests Were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 6 O~-LL~.O~-~.,.,. coNCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0177 Service Date: January 2, 2003 'il'erracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: January 10, 2003 Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 12:57pm Plant: 1 Supplier: Potter Concrete Truck No: 110 Mix I.D. No.: 9385 Ticket No: 12973 Sample Information Sample Time: 1:08pm Date Cast: January 2, 2003 Technician: Jose A. Martinez Weather Conditions: Clear, windy Accumulative Yards: 310 Placement Method: Pump Sample Locations: From bottom of panel 69 Placement Location: See page 1 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.00 1.5 65 58 Set Specimen Diameter Area No. ID (inches) (.sq. inches) 4 1 6.OO 28.27 4 2 6.O0 28.27 4 3 6.00 28.27 4 4 6.00 28.27 4 5 4 6 Specification Test Method 4-5 ASTM C-143 N/A ASTM C-231 55 - 95 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 01/05/2003 3 125,330 4,430 01/05/2003 3 130,200 4,600 Average 4,520 01/09/2003 7 164,650 5,820 01/09/2003 7 166,020 5,870 Average 5,850 01/30/2003 28 01/30/2003 28 Services. Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 6 O~-LL,~O~-F~ cONCRETE COMPRESSIVE STRENGTH TEST 'Report Number: 94021380.0177 Service Date: January 2, 2003 'lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: January 10, 2003 Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 2:06pm Plant: 1 Supplier: Potter Concrete Truck No: 113 Mix I.D. No.: 9385 Ticket No: 12984 Sample Information Sample Time: 2:47pm Date Cast: January 2, 2003 Technician: Jose A. Martinez Weather Conditions: Clear, windy Accumulative Yards: 420 Placement Method: Pump Sample Locations: See placement location Placement Location: See page 1 Sample location: From panel 41 center, 2' each way from top to bottom Field Test Data Test Result Specification Test Method Slump, inches: 4.50 4-5 ASTM C~143 Air Content, %: 1.6 N/A ASTM C-231 Concrete Temperature, o F: 67 55 - 95 ASTM C1064 Ambient Temperature, o F: 57 ASTM Co1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 5 1 6.00 28.27 01/09/2003 7 166,190 5,880 5 2 6.00 28.27 01/09/2003 7 166,840 5,900 Average 5,890 5 3 01/30/2003 28 5 4 01/30/2003 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Jose A. Martinez Report Distribution: (1) Transwestern Commercial Services (1) Hill & Wilkinson, Ltd. (1) O'Brien & Associates (1) TechniStructures (1) City of Coppell - Bldg Insp (1) City of Coppell - Constr Insp (1) State Farm Insurance (1) HBC Engineering Reviewed by: Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 6 o~ LLWIR01-F~U,e Key · d CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0179 Service Date: January 3, 2003 lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: January 10, 2003 Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 Material Information Specified Strength: 4500 psi (~ 28 Days Batch Time: 7:11am Plant: 1 Supplier: Potter Concrete Truck No: Mix I.D. No.: 7753 Ticket No: 12994 Sample Information Sample Time: 7:33am Date Cast:January 3, 2003 Technician: Jose A. Martinez Weather Conditions: Partly cloudy Accumulative Yards: 30 Placement Method: Pump Sample Locations: See placement location Placement Location: Paving N & E of building (See attachments) Field Test Data Test Result Specification Test Method Slump, inches: 5.25 4-5 ASTM C-143 Air Content, %: 7.4 4-8 ASTM C-231 Concrete Temperature,o F: 54 ASTM C1064 Ambient Temperature, o F: 33 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 01/10/2003 7 93,340 3,300 1 2 6.00 28.27 01/10/2003 7 93,700 3,310 Average 3,310 1 3 01/31/2003 28 1 4 01/31/2003 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon, Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 5 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0179 Service Date: January 3, 2003 'll'erracan 8901 Carpenter Fwvy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: Januanj 10, 2003 Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 Material Information Specified Strength: 4500 psi (~ 28 Days Batch Time: 8:03am Plant: 1 Supplier: Potter Concrete Truck No: 105 Mix I.D. No.: 7753 Ticket No: 13002 Sample Information Sample Time: 8:20am Date Cast: January 3, 2003 Technician: Jose A. Martinez Weather Conditions: Partly cloudy Accumulative Yards: 110 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.00 7.2 58 40 Set Specimen Diameter Area No. ID (inches) (sq. inches) 2 1 6.00 28.27 2 2 6.00 28.27 2 3 2 4 Specification Test Method 4-5 ASTM C-143 4-8 ASTM C-231 ASTM C1064 ASTM C- 1064 Age at Date Test Tested (days) 01/10/2003 7 01/10/2003 7 Average 01/31/2003 28 01/31/2003 28 Maximum Compressive Load Strength (lbs) (psi) 80,890 2,860 77,900 2,750 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repod is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 5 01"LLWFF~DI'rCL~Ure Key CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0179 Service Date: January 3, 2003 'lrerr can 8901 Carpenter Fn,vy. Ste #100 Dallas. Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: January 10, 2003 Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 Material Information Specified Strength: 4500 psi ~ 28 Days Batch Time: 9:23am Plant: 1 Supplier: Potter Concrete Truck No: 105 Mix I.D. No.: 7753 Ticket No: 13012 Sample Information sample Time: 9:43am Date Cast:January 3, 2003 Technician: Jose A. Martinez Weather Conditions: Partly cloudy Accumulative Yards: 210 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 5.00 4-5 ASTM C-143 Air Content, %: 7.2 4-8 ASTM C-231 Concrete Temperature,e F: 63 ASTM C1064 Ambient Temperature, o F: 49 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 1 6.00 28.27 01/10/2003 7 101,650 3,590 3 2 6.00 28.27 01/10/2003 7 100,790 3,560 Average 3,580 3 3 01/31/2003 28 3 4 01/31/2003 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM. AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 5 o~-L~,,~0~-,~.,. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0179 Service Date: January 3, 2003 lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: January 10, 2003 Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 Ma teria I In fo rrna tio n Specified Strength: 4500 psi (~ 28 Days Batch Time: 11:00am Plant: 1 Supplier: Potter Concrete Truck No: 113 Mix I.D. No.: 7753 Ticket No: 13022 Sample Information Sample Time: 11:45am Date Cast: January 3, 2003 Technician: Jose A. Martinez Weather Conditions: Partly cloudy Accumulative Yards: 310 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Field Test Data Test Result Slump, inches: 5.00 Air Content, %: 6.5 Concrete Temperature, o F: 65 Ambient Temperature, o F: 55 Plastic Unit Weight, pcf: Laboratory Test Data Specification Test Method 4-5 ASTM C-143 4-8 ASTM C-231 ASTM C1064 ASTM C-1 O64 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 4 1 6.00 28.27 01/10/2003 7 98,380 3,480 4 2 6.00 28.27 01/10/2003 7 95,850 3,390 Average 3,440 4 3 01/31/2003 28 4 4 01/31/2003 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repod is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 5 o, ~L'~o,-,~.y CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0179 Service Date: January 3, 2003 ll'erracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: January 10, 2003 Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 Material Information Specified Strength: 4500 psi (~ 28 Days Batch Time: 12:27pm Plant: 1 Supplier: Potter Concrete Truck No: 103 Mix I.D. No.: 7753 Ticket No: 13032 Sample Information sample Time: 1:00pm Date Cast: January 3, 2003 Technician: Jose A. Martinez Weather Conditions: Partly cloudy Accumulative Yards: 410 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Field Test Data Test Result Slump, inches: 4.75 Air Content, %: 6.8 Concrete Temperature, o F: 65 Ambient Temperature, o F: 61 Plastic Unit Weight, pcf: Laboratory Test Data Specification Test Method 4-5 ASTM C-143 4-8 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 5 1 6.00 28.27 01/10/2003 7 92,960 3,290 5 2 6.00 28.27 01/10/2003 7 94,320 3,340 Average 3,320 5 3 01/31/2003 28 5 4 01/31/2003 28 Services - Obtain samples of fresh concrete at the placement locations, perrorm required field tests and cast compressive strength samples. Technician: Jose A. Martinez Report Distribution: (1) Transwestern Commercial Services (1) Hill & Wilkinson, Ltd. (1) O'Brien & Associates (1) TechniStructures H BC/Ter~_.,~ (1) City of Coppeli - BIdg Insp (1) City of Coppell - Constr Insp Reviewed by: (1) State Farm insurance g,-~ (1) HBC Engineering Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 5 ~, ~Lw,~.,~...~ PROJECT: "~"~/::1 ~pl~s JOB NO. h.q~ Date Comp. By lrerracon Page of CHECKED BY: 0 U 0 rr 121 E 0