Amberpoint BP 2-LR030114FIELD DENSITY TESTING Report Number: 94021380.0193 Service Date: December 27, 2002 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 lrerracon 8901 Carpenter Fn,vy, Ste #100 Dallas, Texas 75247 (214) 630-1010 January 14, 2003 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Proiect Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pot') (%) (% compaction) 1. 213800009 ASTM D 698 Lt brown silty clay 19.2 103.8 -1/+3 95 Field Test Data Probe Test Lift/ Mat. Depth No. Test Location Elevation No. (inches) Paving, Fire Lane (~ NE Corner of Project 948 N Fire Lane, 300' W of Northpoint, 12' S Final 1 6 of N curb 949 N Fire Lane, 150' W of Northpoint, 15' S Final 1 6 of N curb 950 N Fire Lane, 25' W of Northpoint, 9' S of Final 1 6 N curb 951 E Fire Lane, 70' S of Intersection, 28'W Final I 6 of E curb 952 N Fire Lane, 225' W of Northpoint, 6' N of Final I 6 S curb Water Dry Unit Dry Unit Content Weight Weight (%) (pc0 (% compaction) 22.2 100.3 97 20.2 101.3 98 22.1 101.0 97 28.3 * 89.4 86 * 26.1 * 96.3 93 * Comments: An asterisk (*) appears next to test results which do NOT meet the project specifications. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method~,STM D2922, ASTM D3017 Gauge ID: 31787 Field Results Reported To: Contractor Technician: Roy T. Montgomery Report Distribution: (1) Transwestern Commercial Services (1) City of Coppell - Bldg Insp (1) Hill & Wilkinson, Ltd, (1) City of Coppell - Constr Insp (1) O'Brien & Associates (1) State Farm Insurance (1) TechniStructures (1) HBC Engineering Reviewed by: HBC/T~;~ Eugene ~arbcur Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0155 Service Date: December 16, 2002 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: Project: Staples 201 Northpoint Coppell, TX 'lFerracan 8901 Carpenter Fr',w, Ste #100 Dallas, Texas 75247 (214) 630-1010 January 14, 2003 Project Number: 94021380 Material Information Specified Strength: 4500 psi @ 28 Days Batch Time: 4:02am Plant: 1 Supplier: Potter Concrete Truck No: 106 Mix I.D. No.: 7753 Ticket No: 12747 Sample Information sample Time: 4:40am Date Cast: December 16, 2002 Technician: Jose A. Martinez Weather Conditions: Cloudy Accumulative Yards: 40 Placement Method: Pump Sample Locations: See placement location Placement Location: Paving N & NW of building (Concrete daily report & sketch attached) Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature,° F: Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter No. ID (inches) 1 1 1 2 1 3 I 4 Result 5.00 5.7 69 55 Area (sq. inches) 6.00 28.27 6.00 28.27 6.00 28.27 6.00 28.27 Services - Specification Test Method 4-5 ASTM C-143 4-8 ASTM C-231 ASTM C 1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 12/23/2002 7 126,020 4,460 12/23/2002 7 126,330 4,470 Average 4,470 01/13/2003 28 158,720 5,610 01/13/2003 28 153,160 5,420 Average 5,520 Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods, This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials, Page 1 of 6 0~Lw,.0~.~..~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0155 Service Date: December 16, 2002 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: Project: Staples 201 Northpoint Coppell, TX lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 January 14, 2003 Project Number: 94021380 Material Information Specified Strength: 4500 psi @ 28 Days Batch Time: 5:06am Plant: 1 Supplier: Potter Concrete Truck No: 101 Mix I.D. No.: 7753 Ticket No: 12754 Sample Information Sample Time: 5:30am Date Cast: December 16, 2002 Technician: Jose A. Martinez Weather Conditions: Cloudy Accumulative Yards: 110 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.50 7.0 68 55 Set Specimen Diameter Area No. ID (inches) (sq. inches) 2 1 6.00 28.27 2 2 6.00 28.27 2 3 6.00 28.27 2 4 6.00 28.27 Services - Specification Test Method 4-5 ASTM C-143 4-8 ASTM C-231 ASTM C 1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 12/23/2002 7 101,230 3,580 12/23/2002 7 99,250 3,510 Average 3,550 01/13/2003 28 130,720 4,620 01/13/2003 28 129,890 4,590 Average 4,610 Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials, Page 2 of 6 ~.LW~.0~-F~. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0155 Service Date: December 16, 2002 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Material Information Report Date: Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 Sample InfOrmation 'll'erracon 8901 Carpenter Frwy, Ste #1(30 [:)alias, Texas 75247 (214) 630-1010 January 14, 2003 Specified Strength: 4500 psi @ 28 Days Batch Time: 5:54am Plant: 1 Supplier: Potter Concrete Truck No: 110 Ticket No: 12765 Mix I.D. No.: 7753 Sample Time: 6:18am Date Cast: December 16, 2002 Technician: Jose A. Martinez Weather Conditions: Cloudy Accumulative Yards: 220 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.75 7.2 68 56 Set Specimen Diameter Area No. ID (inches) .(sq. inches) 3 1 6.00 28.27 3 2 6.00 28.27 Specification 4-5 4-8 Date Tested 12/23/2002 12~23~2002 3 3 6.00 28.27 01/13/2003 3 4 6.00 28.27 01/13/2003 Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 94,170 3,330 7 93,930 3,320 Average 3,330 28 122,840 4,340. 28 122,300 4,320* Average 4,330 Comments: * Does not comply with specified strength. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 6 ~ ~w~0~.~, CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0155 Service Date: December 16, 2002 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: Project: Staples 201 Northpoint Coppell, TX 'lrerracan 8901 Carpenter Fr~, Ste #100 Dallas, Texas 75247 (214) 630-1010 January 14, 2003 Project Number: 94021380 Material Information Specified Strength: 4500 psi ~ 28 Days Batch Time: 6:48am Plant: 1 Supplier: Potter Concrete Truck No: 106 Mix I.D. No.: 7753 Ticket No: 12774 Sample Information Sample Time: 8:10am Date Cast: December 16, 2002 Technician: Jose A. Martinez Weather Conditions: Cloudy Accumulative Yards: 310 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Field Test Data Test Result Specification Slump, inches: 5.50 Air Content, %: 5.5 Concrete Temperature? F: 67 Ambient Temperature, o F: 59 Plastic Unit Weight, pcf: Laboratorl/ Test Data Test Method 4-5 ASTM C-143 4-8 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 4 1 6.00 28.27 12/23/2002 7 102,070 3,610 4 2 6.00 28.27 12/23/2002 7 103,810 3,670 Average 3,640 4 3 6.00 28.27 01/13/2003 28 133,810 4,730 4 4 6.00 28.27 01/13/2003 28 125,800 4,450* Average 4,590 Comments: * Does not comply with specified strength. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 6 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0155 Service Date: December 16, 2002 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: Project: Staples 201 Northpoint Coppell, TX 'lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 530-I 0t 0 January 14, 2003 Project Number: 94021380 Material Information Specified Strength: 4500 psi ~ 28 Days Batch Time: 8:41am Plant: 1 Supplier: Potter Concrete Truck No: 109 Mix I.D. No.: 7753 Ticket No: 12784 Sample Information Sample Time: 9:15am Date Cast: December 16, 2002 Technician: Jose A. Martinez Weather Conditions: Cloudy Accumulative Yards: 410 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.75 7.4 68 65 Specification Test Method 4-5 ASTM C-143 4-8 ASTM C-231 ASTM C1064 ASTM C-1064 Set Specimen Diameter Area Date No. ID - . (inches) (sq. inches) Tested 5 1 6.00 28.27 12/23/2002 5 2 6.00 28.27 12/23/2002 5 3 6.00 28.27 01/13/2003 5 4 6.00 28.27 01/13/2003 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 91,560 3,240 7 94,790 3,350 Average 3,300 28 126,060 4,46~ 28 128,770 4,550 Average 4,510 Comments: * Does not comply with specified strength. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 6 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0155 Service Date: December 16, 2002 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: Project: Staples 201 Nodhpoint Coppell, TX Project Number: 94021380 'lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 January 14, 2003 Ma terial In formation Specified Strength: 4500 psi @ 28 Days Batch Time: 9:50am Plant: 1 Supplier: Potter Concrete Truck No: 114 Mix I.D. No.: 7753 Ticket No: 12794 Sample Information Sample Time: 10:17am Date Cast: December 16, 2002 Technician: Jose A. Martinez Weather Conditions: Cloudy Accumulative Yards: 510 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.00 6.9 69 65 Set Specimen Diameter Area No. ID (inches) (sq. inches) 6 1 6.00 28.27 6 2 6.00 28.27 6 3 6.00 28.27 6 4 6,00 28.27 Services - Specification Test Method 4-5 ASTM C-143 4-8 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 12/23/2002 7 105,800 3,740 12/2312002 7 102,980 3,640 Average 3,690 01/13/2003 28 131,300 4,640 01/13/2003 28 129,920 4,590 Average 4,620 Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Jose A. Mar[inez Report Distribution: (1) Transwestern Commercial Se~'ices (1) Hill & Wilkinson, Ltd. (1) O'Brien & Associates (1) TechniStructures (1) City of Coppell ~ Bldg Insp (1) City of Coppell - Constr Insp (1) State Farm Insurance (1) HBC Engineering Reviewed by: HBCFF~n Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical Page 6 of 6 ._.'ll'erracan PROJECT: ,,~'"r,¢l P I~.,~ Page of JOB NO. ~0;~1~0,015"~ Date I~,/Ife/e~, Comp. By CHECKED BY: b o 0 0 E -- o~ o