Amberpoint BP 2-LR030113CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0152 Service Date: December 14, 2002. Client: Transwestem Commercial Services Attn: James Gaspard 5001 Spring Valtey Rd Ste 600W Dallas TX 75244 Report Date: Project: Staples 201 Northpoint Coppell, TX 'lrerracon 8901 Carpenter Frwy, Ste #100 DalLas, Texas 75247 (214) 630-1010 January 13, 2003 Project Number: 94021380 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 3:52am Plant: 1 Supplier: Potter Concrete Truck No: 113 Mix I.D. No.: 9337 Ticket No: 12698 Sample Information Sample Time: 4:10am Date Cast: December 14, 2002 Technician: Jose A. Martinez Weather Conditions: Clear Accumulative Yards: 20 Placement Method: Pump Sample Locations: Panel 42, 20' from bottom stops Placement Location: Panels from 42 to 66 (Concrete daily report,attached) Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.50 1.5 60 35 Specification Test Method 4-5 ASTM C-143 N/A ASTM C-231 ASTM C1064 ASTM C-1064 Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 1 1 6.00 28.27 12/21/2002 1 2 6.00 28.27 12/21/2002 I 3 6.00 28.27 01/11/2003 1 4 6.00 28.27 01/11/2003 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 101,480 3,590 7 100,870 3,570 Average 3,580 28 126,850 4,490 28 132,370 4,680 Average 4,590 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods, This report is exclusively for the use of the Client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials, o, LLW.~-.,*~. Page 1 of 5 .CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0152 Service Date: December 14, 2002 'irerr can 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: January 13, 2003 Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 Material information Specified Strength: 3500 psi ~ 28 Days Batch Time: 4:54am Plant: 1 Supplier: Potter Concrete Truck No: 104 Mix I.D. No.: 9337 Ticket No: 12707 Sample Information Sample Time: 5:15am Date Cast: December 14, 2002 Technician: Jose A. Martinez Weather Conditions: Clear Accumulative Yards: 110 Placement Method: Pump Sample Locations: Panel 46 Placement Location: See page 1 Field Test Data Test Result Slump, inches: 5.00 Air Content, %: 1.5 Concrete Temperature, o F: 59 Ambient Temperature, o F: 35 Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area No. iD (inches) (sq. inches) 2 1 6.00 28.27 2 2 6.00 28.27 2 3 6.00 28.27 2 4 6.00 28.27 Specification Test Method 4-5 ASTM C-143 N/A ASTM C-231 ASTM C 1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 12/21/2002 7 114,920 4,060 12/21/2002 7 111,140 3,930 Average 4,000 01/11/2003 28 150,610 5,330 01/11/2003 28 145,910 5,160 Average 5,250 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in generat accordance with applicable ASTM. AASHTO. or DOT test methods: This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 5 .,-LLW,"O, CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0180 j~.i l~__./ Service Date: January 4, 2003 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 epod Date: 'lrerracan 8901 Carpenter Frw,/, Ste #100 Dallas, Texas 75247 (214) 630-1010 January 13, 2003 Project Number: 94021380 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 9:15am Supplier: Hanson Truck No: 1092 Mix I.D. No.: 9115 Plant: 29 Ticket No: 318626 Sample Information sample Time: 10:25am Date Cast: January 4, 2003 Technician: Bryan C. Hughes Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: From NE corner of approach = 8' S & 15' W Placement Location: Paving- leaveout @ NE approach to Northpoint Drive Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laborator~ Test Data Result 4.50 4.9 54 58 Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 I 3 1 4 Specification Test Method 4-5 ASTM C-143 4-8 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 01/11/2003 7 96,240 3,400 01/11/2003 7 95,000 3,360 Average 3,380 02/01/2003 28 02/01/2003 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Bryan C. Hughes Report Distribution: (1) Transwestern Commercial Services (1) Hill & Wilkinson, Ltd. (1) O'Brien & Associates (1) TechniStruclures (1) City of Coppell - 81dg Insp (1) City of Coppell - Constr Insp (1) Slate Farm insurance (1) HBC Engineering Reviewed by: HBC/Ter~n~ Eugene Harbour Principal The testa were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical Page 1 of 1 CONCRETE COMPRESSIVE STRENGTH TEST 'Report Number: 94021380.0152 Service Date: December 14, 2002 ']rerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: January 13, 2003 Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 Material Information Specified Strength: 3500 Fsi (~ 28 Days Batch Time: 6:16am Plant: Supplier: Potter Concrete Truck No: 113 Mix I.D. No.: 9337 Ticket No: 12718 Sample Information sample Time: 6:30am Date Cast: December 14, 2002 Technician: Jose A. Martinez Weather Conditions: Clear Accumulative Yards: 220 Placement Method: Pump Sample Locations: Panel 51, Half & to the top of panel Placement Location: See page 1 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboraton/ Test Data Result 5.50 1.3 60 35 Set Specimen Diameter Area No. ID (inches) (sq. inches) 3 1 6.00 28.27 3 2 6.00 28.27 3 3 6.00 28.27 3 4 6.00 28.27 Services - Specification Test Method 4-5 ASTM C-143 N/A ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 12/21/2002 7 99,580 3,520 12/21/2002 7 99,170 3,510 Average 3,520 01/11/2003 28 135,860 4,800 01/11/2003 28 137,890 4,880 Average 4,840 Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 5 o~.Lw~.o~.r~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0152 Service Date: December 14, 2002 'll'erracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestem Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: January 13, 2003 Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 Material Information Specified Strength: 3500 psi ~ 28 Days Batch Time: 7:11am Plant: 1 Supplier: Potter Concrete Truck No: 103 Mix I.D. No.: 9337 Ticket No: 12727 Sample Information Sample Time: 7:38am Date Cast: December 14, 2002 Technician: Jose A. Martinez Weather Conditions: Clear Accumulative Yards: 310 Placement Method: Pump Sample Locations: Panel 57, bottom to halfway Placement Location: See page 1 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen No. ID 4 1 4 2 Result Specification Test Method 5.50 4-5 ASTM C-143 1.9 N/A ASTM C-231 61 ASTM C1064 37 ASTM C-1064 Age at Maximum Compressive Diameter Area Date Test Load Strength (inches) (sq. inches) Tested (days) (lbs) (psi) 6.00 28.27 12/21/2002 7 86,950 3,070 6.00 28.27 12/21/2002 7 88,430 3,130 Average 3,100 6.00 28.27 01/11/2003 28 115,210 4,070 6.00 28.27 01/11/2003 28 118,770 4,200 Average 4,140 4 3 4 4 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repod is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 5 O~-~L~.O~-~. ,CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0152 Service Date: December 14, 2002 'll'err can 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: January 13, 2003 Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 Material Information Specified Strength: 3500 psi ~ 28 Days Batch Time: 8:19am Plant: 1 Supplier: Potter Concrete Truck No: 113 Mix I.D. No.: 9337 Ticket No: 12737 Sample Information Sample Time: 8:35am Date Cast: December 14, 2002 Technician: Jose A. Martinez Weather Conditions: Clear Accumulative Yards: 410 Placement Method: Pump Sample Locations: Panel 42, Half way & to the top of panels Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 5.25 4-5 ASTM C-143 Air Content, %: 1.8 N/A ASTM C-231 Concrete Temperature,o F: 62 ASTM C1064 Ambient Temperature, o F: 45 ASTM C-1064 Plastic Unit Weight, pcf: Laboratorv Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 5 1 6.00 28.27 12/21/2002 7 95,310 3,370 5 2 6.00 28.27 12/21/2002 7 94,790 3,350 Average 3,360 5 3 6.00 28.27 01/11/2003 28 132,190 4,670 5 4 6.00 28.27 01/11/2003 28 130,110 4,600 Average 4,640 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Jose A. Martinez Report Distribution: (1) Transwestern Commercial Services (1) Hill & Wilkinson, Ltd. (1) O'Brien & Associates (1) TechniStructures (1) City of Coppell - Bldg Insp (1) City of CoppeH - Constr Insp (1) State Farm insurance (1) HBC Engineering Reviewed by: HBC/Terracon Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propedies of other apparently similar or identical materials. Page 5 of 5 o~ LLW~"~,-F,"~, ~ d