Loading...
Freeport NIP(7.0)-CS030122January 22, 2003 Jack Evans Pacheco Koch 8350 N. Central Expwy., Suite 1000 Dallas, TX 75206 T H E •C 1 T Y •O F CQPPELL 0 RE: Duke Freeport X (The Container Store) Construction Review Comments Dear Mr. Evans: The City of Coppell has reviewed the referenced plans and has the following comments to offer: General: 1. All work must be coordinated with the construction of Ruby Road. 2. Install a waterproof liner in the detention pond to minimize water loss. See the attached Sheet L -6A of the Wagon Wheel Park detention pond plans. Plat: 1. Curves C109, C110, C117, C118, C123, and C124 do not meet the minimum firelane curve radius requirements. Verify with the fire marshal that this is acceptable. 2. Label the firelane /access easement that was recently dedicated from Freeport IX. 3. A 4 -foot sidewalk will be required along Ruby Road. Sheet C3.3: Show the limits of the ponded water in the truck courts similar to how it was shown in the Freeport IX plans (Uline). Sheets C3.4 C3.5: Show all waterline and sanitary sewer crossings in the storm sewer profiles. Sheet C4.0: The maximum spacing between sanitary sewer cleanouts is 200 feet. Sheet C4.2: Core and bore to connect Line SS 2 to the existing sanitary sewer manhole. Sheet C5.0: Submit a letter of request to waive the lime stabilization requirement. There are various other minor comments throughout the plans. When all comments have been addressed, please return these marked plans and two sets of revised plans to the City for review. If you have any questions, please contact me at (972) 304 -3681. Sincerely, Teresa Turner, E.I.T. Graduate Engineer 255 PARKWAY P.O.BOX 478 COPPELL TX 75019 TEL 972/462 0022 FAX 972/304 3673 Phone: T H E C 1 T Y O F COPPELL ENGINEERING DEPARTMENT FAX COVER SHEET To: Jack Evans From: Teresa Tumer Fax: 972 235 -9544 Date: 1/22/03 Re: Freeport X (The Container Store) CC: Urgent ❑For Review Jack: P.O. Box 478 255 Parkway Blvd Coppell, TX 75019 Phone: (972)304-3681 Fax: (972)304 -3570 Pages: 2 (including cover sheet) Please Comment Please Reply As Requested Please see the attached construction plan review comments. The original letter and the mark -ups may be picked up in the engineering office at your convenience. If you have any questions, please feel free to contact me at 972 304-3681. IF YOU DO NOT RECEIVE ALL OF THE PAGES PLEASE CALL (972) 304 -3679 "City of Coppell Engineering Excellence By Design"