Amberpoint BP 2-LR030123CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0197 Service Date: January 15, 2003 'lrerracan 6901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date: Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 January 23, 2003 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 8:55am Supplier: Potter Concrete Truck No: 111 Mix I.D. No.: 7753 Ticket No: 113183 Sample Information Sample Time: 10:10am Date Cast: January 15, 2003 Technician: Melvin L. Searles Weather Conditions: Cloudy, cold Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: See placement Iocatibn Placement Location: Archatectural leaveout in SE approach to Northpoint Field Test Data Test Result Specification Test Method 4.50 4-5 ASTM C-143 4.0 4-8 ASTM C-231 60 ASTM C1064 45 ASTM C-1064 Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature,o F: Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 01/22/2003 7 122,380 4,330 1 2 6.00 28.27 01/22/2003 7 131,320 4,640 Average 4,490 1 3 02/12/2003 28 1 4 02/12/2003 28 1 5 Hold Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Melvin L. Searles Report Distribution: (1) Transwestern Commercial Services (1) O'Brien & As$oc (1) Hill & Wilkinson LTD (2) Carter & Burgess Inc (1) TechniStructures (1) City of Coppe[I - Bldg Insp (1) City of Coppell - Constr Insp (1) Staples Reviewed by: HBC/~~con Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 O,-L~W~O, CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0192 Service Date: Januanj 14, 2003 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 'lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: Project: Staples 201 Nodhpoint Coppell, TX January 23,2003 Project Number: 94021380 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 11:45am Plant: 1 Supplier: Potter Concrete Truck No: 109 Mix I.D. No.: 9337 Ticket No: 113166 Sample Information sample Time: 12:10pm Date Cast:January 14, 2003 Technician: Jose A. Martinez Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: Bottom half of panel#2 Placement Location: Panels 1 thru 4 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature,° F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.00 1.6 60 65 Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 1 3 6.00 28.27 1 4 6.00 28.27 I 5 Specification Test Method 4-5 ASTM C-143 N/A ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 01/17/2003 3 57,950 2,050 01/17/2003 3 57,650 2,040 Average 2,050 01/21/2003 7 101,250 3,580 01/21/2003 7 104,420 3,690 Average 3,640 02/1112003 28 02/11/2003 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Jose A. Martinez Report Distribution: (1) Transwestern Commercial Services (1) O'Brien &Assoc (1) Hill &Wilkinson LTD (2) Carter & Burgess Inc HBC/Ter~ (1) TechniStructures (1) City of Ceppell - BIdg Insp Reviewed by: (1) City of Coppell - Constr Insp Eugene H~lrbour (1) Staples Inc Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon, Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 01'LLW'~R01'Fb~uce~eY