Amberpoint BP 2-LR030206CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0216 Service Date: January 28, 2003 lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 530-1010 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date: Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 February 06, 2003 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 8:54am Plant: 1 Supplier: Potter Concrete Truck No: 112 Mix I.D. No.: 9349 Ticket No: 113326 Sample Information Sample Time: 9:20am Date Cast:January 28, 2003 Technician: Jose A. Martinez Weather Conditions: Cloudy Accumulative Yards: Placement Method: Sample Locations: Placement Location: 10 Motorized Buggy Grid line A & from 8 to 6 Slab leaveout & bathrooms leaveout & elevator pit (See attachment) Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.25 1.6 62 55 Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 1 3 1 4 Specification 4-5 N/A Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 02/04/2003 7 115,160 4,070 02/04/2003 7 110,900 3,920 Average 4,000 02/25/2003 28 02/25/2003 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Jose A. Martinez Repod Distribution: (1) Transwestern Commercial Services (1) O'Brien & Assoc (1) Hill & Wilkinson LTD (1) TechniStructures (2) Carter & Burgess Inc (1) City of Coppell - Constr Insp (1) Cily of Coppell - Bldg Insp (1) Stale Farm insurance Co Reviewed by: HBC/T~ Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AAS HTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propedies of other apparently similar or identical materials. Page 1 of 1 FIELD DENSITY TESTING Report Number: 94021380.0219 Service Date: January 28, 2003 'll'erracan 8901 Carpenter Fn~vy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services At/n: James Gaspard 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date: Project: Staples 201 Northpoint Coppell, TX February 06, 2003 Project Number: 94021380 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Project Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pcf) (%) (% compaction) 1. 213800010 ASTM D 698 Brown clay 22.7 98.7 =/> +3 92 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pct') (% compaction) Leaveout Backfill 1003 Grid line A.5/11 1st 1 6 26.4 93.6 95 1004 Grid line C.5/11 1st 1 6 27.3 92.7 94 1005 Grid line E.5/11 1st 1 6 26.9 93.3 95 1006 Grid line F.5/11 1st 1 6 27.7 91.7 93 1007 Grid line H.5/11 1st 1 6 28.3 93.8 95 Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Gauge ID: Field Results Reported To: ContractodBdan Technician: Bradford T. Rengstorff Report Distribution: (1) Transwestem Commemial Services (2) Car[er & Burgess Inc (1) O'Bden & Assoc (1) City of Coppell - Constr Insp (1) Hill & Wilkinson LTD (1) City of Coppell- Bldg Insp (1) TechniStructures (1) State Farm Insurance Co Reviewed by: HBCfTe,~ Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1