Amberpoint BP 2-LR030210FIELD DENSITY TESTING
Report Number: 94021380.0222
Service Date: January 30, 2003
'll'erracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Client: Transwestern Commercial Services
Attn: James Gaspard
5001 Spring Valley Rd Ste 600 W
Dallas TX 75244
Report Date:
Project: Staples
201 Northpoint
Coppell, TX
Project Number: 94021380
February 10, 2003
Material Information
Material Laboratory
No. Test Method
Description and Classification
Lab Test Data Project Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Content Weight Range Unit Weight
(%) (pc0 (%) (% compaction)
1. 213800010 ASTM D 698 Brown clay 22.7 98.7 =/> +3
92
Field Test Data Probe Water Dry Unit
Test LiftJ Mat. Depth Content Weight
No. Test Location Elevation No. (inches) (%) (pcf)
Building Leaveout
1016 Grid line A.5/11 3rd 1 6 26.9 91.8
1017 Grid line C/11 3rd 1 6 27.4 92.4
1018 Grid line E/11 3rd 1 6 27.8 92.6
1019 Grid line G.5/11 3rd 1 6 28.3 91.4
1020 Grid line J/10.5 1st 1 6 27.2 92.7
1021 Grid line J/9.0 1st 1 6 26.1 93.6
1022 Grid line J/7.5 1st 1 6 25.9 94.7
1023 Grid line J/6.0 1st 1 6 26.7 93.7
Dry Unit
Weight
(% compaction)
93
94
94
93
94
95
96
95
Comments:
Test results on this report meet project specification.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method:ASTM D2922, ASTM D3017
Gauge ID:
Field Results Reported To: Brian w/Hill & Wilkinson
Technician: Bradford T. Rengstorff
Report Distribution:
(1) Transwestem Commercial Services (2) Carter & Burgess Inc
(1) O'Bden & Assoc (1) City of Coppell - Constr Insp
(1} Hill & Wilkinson LTD (1) City of Coppell - BIdg Insp
(1) TechniStructures (1) State Farm insurance Co
Reviewed by:
Eugene Harbour
Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1