FS9901-CS030106Xu, Allen
From:
Sent:
To:
Subject:
Yi, Scott S [SSYi@pbsj.com]
Monday, January 06, 2003 5:32 PM
'Axu @ Halff.com'
Case 02-06-1090P
Allen,
Z have reviewed your most recent submittal, dated December 3,
2002.
There ore issues that still need to be addressed for this case. To
date,
all the items requested in the request letter dated, ,Tuly 29, 2002 have
not
be received. The major issue is concerning the hydraulic models and the
topographic work map. Per Subparagraph 65.6(a)(2) of the IqFIP
regulations,
revised and unrevised hydraulic analyses must have a transition between
revised elevations. This transition should be within 0.5 foot, no more.
Based on your recent submittal, this requirement is not met. Also,
there
are some hydraulic models that do not include all cross sections (for
example, floodway models did not include all cross sections).
To date, here is what is still needed.
Corrected Effective and Post Project hydraulic models (natural
and
floodway) that tie into the effective hydraulic model,
0.5
foot.
within at least
Corrected Effective and Post Project hydraulic floodway models
that
includes all cross sections (up until tie in).
Need to extend work map to include all cross sections up until
tie
in location.
Please note, these items were requested within the CLOAAR letter.
Unfortunately, I have more bad news. I could no longer keep
1
this
case open. Due to the inactive status for over 90 days, this case had
to be
suspended. ]: tried to keep it going, but eventually had no choice.
When
these items have been addressed and submitted, a new case will have to
be
opened and subject to new fees. However, due to the comp[exity of this
case, you may be able to have the fee transferred. To do this, Z would
need
a very detailed [etter explaining the complexity of the case. Then I
will
present it to the project engineer from FEMA and it would be up to him
whether to transfer the fees.
If you have any questions, or concerns, feel free to call or
ema il
and I would be glad to discuss these items with you.
Scott Yi
Floodplain Engineer
PBS&,T
12101 Indian Creek Court
Beltsville, MD 20705
Phone (800) 697-7275 Ext. Z64
Fax (3010 210-5157