Amberpoint BP 2-LR030212FIELD DENSITY TESTING
Report Number: 94021380.0226
Service Date: January 31,2003
'll'erracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Client: Transwestern Commercial Services
Attn: James Gaspard
5001 Spring Valley Rd Ste 600 W
Dallas TX 75244
Report Date:
Project: Staples
201 Northpoint
Coppell, TX
Project Number: 94021380
February 12,2003
Material Information Lab Test Data
Optimum Max. Lab
Water Dry Unit
Material Laboratory Content Weight
No. Test Method Description and Classification (%) (pcf)
Proiect Requirements
Water
Content Minimum Dry
Range Unit Weight
(%) (% compaction)
1. 213800073 ASTM D 698 Lt brown day (lime treated)
21.3 98.8 -1/+3 95
Field Test Data Probe Water Dry Unit
Test Lift/ Mat. Depth Content Weight
No. Test Location Elevation No. (inches) (%) (pcf)
Leaveout Backfill
1024 Grid line A.5/11 Final 1 6 22.1 94.7
1025 Grid line C/11 Final 1 6 23.4 95.6
1026 Grid line D.5/11 Final 1 6 20.6 97.7
1027 Gdd line F/11 Final 1 6 21.7 96.4
1028 Grid line G.5/11 Final 1 6 22.4 97.3
1029 Grid line J/9.5 Final 1 6 23.6 94.9
1030 Grid line J/8 Final 1 6 21.7 95.7
1031 Grid line J/6.5 Final 1 6 22.6 96.3
Dry Unit
Weight
(% compaction)
96
97
99
98
98
96
97
97
Comments:
Test results on this report meet project specification.
Services - Perform in-place density and moisture content tests to determine.degree of compaction and material moisture
condition.
Field Test Method:ASTM D2922, ASTM D3017
Gauge ID:
Field Results Reported To: Brian w/Hill & Wilkinson
Technician: Bradford T. Rengstorff
Report Distribution:
(1) Transwestern Commercial Services (2) Carter & Burgess Inc
(1) O'Bden & Assoc (1) City of Coppell - Constr Insp
(1) HEll & Wilkinson LTD (1) City of Coppell - Bldg Insp
(1) TechniStructures (1) State Farm Insurance Co
Reviewed by[
HBC
Eugene Harbour
Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1 ~.~,~7-,....~