Loading...
Creekview P2 L1R BA-LR030212ALPHA TESTING, INC. 2209 Wisconsin St., Suite 10 Dallas, Texas 75229 (972) 620-8911 Tested For: TRI-STAR CONSTRUCTION AT-TN: MR. FRED DONALDSON 220 ELM STREET. SUITE 100 LEWISVILLE. TX 75057 Fax Number: (972) 219-7099 Concrete Compression Test Report Our Report No.: 02741-30 Issue Date: 02/12/2003 Project Desc: SALON ON THE CREEK 684 SOUTH DENTON TAP ROAD Placement Location: J PAVING, DENTON DR. APPROACH Date Placed: 1/9/03 Time Placed: N/A Slump (ASTM C-143): N/A Air Content: N/A Air Temperature: N/A Specimen Temperature: N/A Date Received: 1/10/03 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: Mix Data Submitted By: FIELD DATA Plant Number: N/A Delivery Ticket No.: N/A Made By: Cured Specification: ASTM C-31 N/A CYLINDER COMPRESSION TEST RESULTS ~ab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI: 53 LAB C-1231 1/16/03 7 12 N/A 6 28.27 109280 3860 54 LAB C-1231 2/6/03 28 12 N/A 6 28.27 142870 5050 55 LAB C-1231 2/6/03 28 12 N/A 6 28.27 136820 4830 56 LAB HOLD HOLD 12 N/A 6 28.27 0 28 3600 Specifications: ~ PASS Results to Date: ~ Notes: CLIENT MADE CYLINDERS CC: TRI-STAR CONSTRUCTION. CITY OF COPPELL, CD CONSTRUCTION CONSULTING Respectfully Submitted By: . J/,~/". ~ of Alpha Testing, Inc. Our test results and reports are fo~ the exc usive use f~the cr~t (and the r designated recep en s on file in our office) and shall not be reproduced and/or distributed except with express approva of ALPHA The use of our narn'e and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. ~ . ~ ~: ,,5 : .~ ,.r'l:: : G~,0tec~lnlcal E~gln~e~;ing'~,,Construct!on Materials Testing * Environmental Engineering * Consulting 21971