Creekview P2 L1R BA-LR030123ALPHA TESTING, INC. 2209 Wisconsin St., Suite 10 Dallas, Texas 75229 (972) 620-8911 Tested For: TRI-STAR CONSTRUCTION ATTN: MR. FRED DONALDSON 220 ELM STREET, SUITE 100 LEWlSVILLE, TX 75057 Fax Number: (972) 219-7099 Project Dssc: SALON ON THE CREEK 684 SOUTH DENTON TAP ROAD Concrete Compression Test Report Our Report No.: 02741-30 Issue Date: 01/23/2003 FIELD DA TA Placement Location: PAVING, DENTON DR. APPROACH Date Placed: 1/9/03 Time Placed: N/A Slump (ASTM C-143): N/A Air Content: N/A Air Temperature: N/A Specimen Temperature: NIA Date Received: 1/10/03 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: Mix Data Submitted By: NIA Plant Number: Delivery Ticket No.: Made By: Cured Specification: CYLINDER COMPRESSION TEST RESULTS ~ Cure Cap Date Age Avg. Avg. Avg Depth/ Area: No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. 53 LAB C-1231 1116103 7 12 N/A 6 28.27 54 LAB 2~6/03 28 12 N/A 6 28.27 '~ LAB 2/6/03 28 12 N/A 6 28.27 56 LAB HOLD HOLD 12 N/A 6 28.27 .... 26 i Specifications: ~ Results to Date: Notes: CLIENT MADE CYLINDERS CC: TRI-STAR CONSTRUCTION, CiTY OF COPPELL, CD CONSTRUCTION CONSULTING N/A N/A ASTM C-31 Max Load: PSI: 109280 3860 0 0 0 Respectfully Submitted By: ,.,~// of Atpha Testing, Inc. Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative o[ the qualities of apparently identical or similar specimens, ~ ...... ~ ................................. ~ t On Mat~l:ials'Test ng * Environmental Engineering * consulting ,~,,~,.,:,~,~: ~.. ', ', ',' Geotechnlcal Engineering Construc 21971 ALPHA TESTING, INC. 2209 Wisconsin St., Suite 10 Dallas, Texas 75229 (972) 620-8911 Tested For: TRI-STAR CONSTRUCTION ATTN: MR. FRED DONALDSON 220 ELM STREET, SUITE 100 LEWISVILLE, TX 75057 Fax Number: (972) 219-7099 Project Desc: SALON ON THE CREEK 684 SOUTH DENTON TAP ROAD Concrete Compression Test Report Our Report No.: 02741-28 Issue Date: 01/22/2003 Placement Location: Date Placed: Time Placed: Slump (ASTM C-143): Air Content: Air Temperature: Specimen Temperature: Date Received: Delivery Method: Field Data Submitted By: Mix Data Submitted By: FIELD DA TA PAVING, 20'S OF TRASH ENCLOSURE & 15'N OF S. CURB LINE 12/19/02 N/A NIA NIA N/A NIA 12/20/02 PICKED UP BY ALPHA CONTRACTOR N/A Plant Number: N/A Delivery Ticket No.: N/A Made By: CONTRACTOR Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESULTS ~ Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI: 49 LAB C-1231 12/26/02 7 12 N/A 6 28.27 90210 3190 50 LAB C-1231 1/16/03 28 12 N/A 6 28.27 130790 4620 51 LAB C-1231 1/16/03 28 12 N/A 6 28.27 128220 4530 52 LAB HOLD HOLD 12 N/A 6 28.27 0 3000 Specifications: 28 PASS Results to Date: ~ Notes: LOCATION PROVIDED BY CONTRACTOR. CC: TRI-STAR CONSTRUCTION, CITY OF COPPELL, CD CONSTRUCTION CONSULTING Respectfully Submitted By: .J~'~ ~ of Alpha Testing, Inc. e exclusive use orl~e CliPS (and their designated receplents on file in our office and shall not be reproduced and/or distributed except Our test resultS and repor~ are for th onl to the sam les tested and/or with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reporu apply y P observed, and are not Indicative of the qualities of apparendy Identical or similar specimens. ~ .................... ........ ~w.'~':'~':"~'~'~C%~;-;':Z:,:..'.[i(~ M~t~,~iai~'Te~stlng, En~l~or{m&ntal Engineering * c~~s'ulflng ' 21602