Creekview P2 L1R BA-LR021223ALPHA TESTING, INC.
2209 Wisconsin St., Suite 10
Dallas, Texas 75229
(972) 620-8911
Tested For: TRI-STAR CONSTRUCTION
ATTN: MR. FRED DONALDSON
220 ELM STREET, SUITE 100
LEWISVILLE, TX 75057
Fax Number: (972) 219-7099
Project Desc: SALON ON THE CREEK
684 SOUTH DENTON TAP ROAD
Concrete Compression Test
Report
Our Report No.: 02741-22
Issue Date: 12/23/2002
FIELD DA TA
Placement Location: FIRELANE
Date Placed: 11/22/02
Time Placed: N/A
Slump (ASTM C-143): N/A
Air Content: N/A
Air Temperature: N/A
Specimen Temperature: N/A
Date Recalvad: N/A
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By:
Mix Data Submitted By: N/A
Plant Number: N/A
Delivery Ticket No,: N/A
Made By:.
Cured Specification: ASTM C-31
CYLINDER COMPRESSION TEST RESUL TS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Da~/s): Length Width Diameter Sq. In. Load: PSI:
37 LAB C-1231 11129/02 7 12 NIA 6 28.27 165710 5860
38 LAB C-1231 12/20/02 28 12 N/A 6 28.27 198920 7030
39 LAB C-1231 12/20/02 28 12 N/A 6 28.27 193190 6830
40 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28 3000
PASS
, Results to Date:
Notes: CLIENT MADE CYLINDERS
CC: TRI-STAR CONSTRUCTION, CITY OF COPPELL, CD CONSTRUCTION CONSULTING
Respectfully Submitted By: J~;¢"'"~ of Alpha Testing, Inc.
Our test results and repots are fo~ the exclusive use o~A~e Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed
excaptw~thexpressapprovalofALPHA. The use of our name and test results must receiveourwdttenapproval. Testresultsandreportsapplyonlytothesamples
tested and/or observed, and are not indicative of t~e qualities of apparently identical or similar specimens.