Creekview P2 L1R BA-LR021126ALPHA TESTING, INC.
2209 Wisconsin St., Suite 10
Dallas, Texas 75229
(972) 620-8911
Tested For: TRIiSTAR CONSTRUCTION
ATTN: MR. FRED DONALDSON
220 ELM STREET, SUITE 100
LEWISVILLE, TX 75057
Fax Number: (972)219-7099
Project Desc: SALON ON THE CREEK
684 SOUTH DENTON TAP ROAD
Concrete Compression Test
Report
Our Report No.: 02741-13
Issue Date: 11/26/2002
FIELD DA TA
Placement Location: PIERS; A-2, A-I, B-l, D-l, E-l, F-I
Date Placed: 10/24/02
Time Placed: N/A
Slump (ASTM C-143): N/A
Air Content: N/A
Air Temperature: N/A
Specimen Temperature: N/A
Date Received: 10/25/02
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By:
Mix Data Submitted By: N/A
Plant Number: N/A
Delivery Ticket No.: N/A
Made By:
Cured Specification: ASTM C-31
CYLINDER COMPRESSION TEST RESUL TS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI:
13 LAB C-1231 10/31/02 7 12 N/A 6 28.27 78710 2780
14 LAB C-1231 11/21/02 28 12 N/A 6 28.27 124450 4400
15 LAB C-1231 11/21/02 28 12 N/A 6 28.27 120350 4250
16 LAB HOLD HOLD 12 N/A 6 28.27 0
Specificat!0?~s: 28 3000
Results to Date: PASS
Notes: CLIENT MADE CYLINDERS
CC: CD CONSTRUCTION CONSULTING, TRI-STAR CONSTRUCTION, CITY OF COPPELL
Respectfully Submitted By:"// '~ //'"~ .,~,~_ ' of Alpha Testing, Inc.
Our test results and reports are for the exclusive use°l~/the~'~n/t (and their designated recepients on file In our office)and thall not be reproduced and/or distributed except
observed, and are not Indicative of the qualities of apparenHy Identical or simll,lr specimens.
' ' Oeotechn!cal Englnesrln~Constructlon Materials Testing* Environmental Englneerlng Consulting 20387