Creekview P2 L1R BA-LR030219ALPHA TESTING, INC.
//'. 2209 Wisconsin St., Suite 10
Dallas, Texas 75229
(972j 620-8911
Concrete Compression Test
Report
Tested For. TRISTAR CONSTRUCTION
ATTN: MR. PRED DONALDSON
220 ELM STREET, SUITE 100
LEWISVILLE,TX 75057
Fax Number: (972) 219-7099
Pro)eet Dese: SALON ON THE CREEK
684 SOUTH DENTON TAP ROAD
Our Repoli No.: 02741-33
Issue Date: 02/19/2003
FJELD DATA
Placement Loptlon: STAMPED CONCRETE APPROACH ~ 864 DENTON TAP RD.
Date Placsd:
Time Placed:
Stump (ASTM C•143):
Air Content:
Air Tampereture:
Specimen Temperature:
Dab Received:
De1Nery Method:
Field Data Submitted By:
Mlx Data Submitted By:
1!21103
N/A
N/A
N/A
N!A
N/A
1!22!03
PICKED UP BY ALPHA
N!A
Plant Number: N/A
Delivery Ticket No.: N/A
Made By:
Cured Specification: ASTM C-31
CYLINDER COMPRESSION TEST RESULTS
Lab Cure
No.: T Cap
Spec: Dab
Tested: Age
(Da ): Avg.
Len th Avg.
Width Avg Depth!
Diameter Area:
S .In. Max
Load:
PSI:
61 LAB C-1231 1128103 7 12 N/A 6 28.27 135060 4770
62 LAB C-1231 211$/03 28 12 N/A 6 28.27 175320 6200
63 LAB C-1231 2118103 28 12 N/A 6 28.27 182940 6470
64 LAB HOLD HOLD 12 N/A 6 28.27 0
Speciflcadons: 28 4000
Results to Date: PASS
Notes: CLIENT MADE CYLINDERS
CC: TRI-STAR CONSTRUCTION, CITY OF COPPELL, CD CONSTRUCTION CONSULTING
Respectfully Submitted
of Alpha Testing, Inc.
Our tes[ rtwlts and reporo arc for the exGuslve u>t(of ehF Clknt (and their desl~aced receAlents on flk In our otAce) and shall not be reproduced and/or dtstrlbuted except
with express approval of ALPHA. The use of our wine and tea rewhs mart receive our written approval. Test results and reports appry only tothe samples tested and/or
observed, and are not IndkatNe of the gwlitles of apparenty Identlwl or similar spedmem.
N
cdo~'t~.,~~!t~fer"~"`,a_estlnQ;~_i~vlroori~eilt#TEngrneerin~{~4~sultitit~;r~ ,~t~~~2241.