Amberpoint BP 2-LR030219 (2)FIELD DENSITY TESTING
Report Number: 94021380.0244
Service Date: February 11,2003
.- " ll'erracan
~ 8D~llla~aTreP;~n~e;5~2,n~/7, Ste #100
(214) 630-1010
Client: Transwestern Commercial Services
Attn: James Gaspard
5001 Spring Valley Rd Ste 600 W
Dallas TX 75244
Coppell, TX
Project Number: 94021380
February 21, 2003
Material Information
Material Laboratory
No. Test Method
Description and Classification
Lab Test Data Project Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Content Weight Range Unit Weight
(%) ' (pc0 (%) (% compaction)
1. 213800009 ASTM D698
2. 213800074 ASTM D 698
Field Test Data
Test
No.
Lt brown silty clay
Dk brown clay (lime treated)
Test Location
Lift/ Mat.
Elevation No.
Parking Lot Subgrade
1054 45' S of gdd line A/5
1055 30' N of grid line J/1.5
Ramp Subgrade
1056 20' W of grid line H.8/11
1057 60' W of gdd line H.7/11
Bathroom Subgrade
1058 Grid Line F.7/2.4
19.2 103.8 -1/+3 95
22.9 95.5 -1/+3 95
Probe Water Dry Unit Dry Unit
Depth Content Weight Weight
(inches) (%) (pcf) (% compaction
At grade 1 6 18.7 101.9 98
At grade 1 6 20.3 100.6 97
At grade 1 6 19.6 102.8 99
At grade 1 6 19.4 103.4 100
At grade 2 6 22.6 91.9 96
Comments:
Test results on this report meet project specification.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material 'moisture
condition.
Field Test Method:ASTM D2922, ASTM D3017
Gauge ID:
Field Results Reported To: Brian w/Hill & Wilkinson
Technician: Bradford T. Rengstorff
Report Distribution:
(1) Transwestern Commercial Services (1) TechniStructures
(1) O'Brien & Assoc (1) City of Coppell - Bldg Insp
(1) Hill & Wilkinson LTD (1) City of Coppell - Constr Insp
(2) Carler & Burgess Inc (I) HBC Engineering Inc
HBCfTerracon
Reviewed by: Eugen~ ~ur
Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approvat of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not neceseadly indicative ol' the properties of other apparently similar or identical
materials.
Page 1 of 1