Amberpoint BP 2-LR030303FIELD DENSITY TESTING
Report Number: 94021380.0247
Service Date: February 17, 2003
'll'erracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Client: Transwestern Commercial Services
Attn: James Gaspard
5001 Spring Valley Rd Ste 600 W
Dallas TX 75244
· R~e~ Date:
P~ject: Staples _ _.,
~01 Northpoint
Coppell, TX
March 03, 2003
Material Information
Material Laboratory
No. Test Method
nt Project Number:
ion and Classification
94021380
Lab Test Data Proiect Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Content Weight Range Unit Weight
(%) (pc0 (%) (% compaction)
1. 213800009 ASTM D 698 Lt brown silty clay
Field Test Data
Test
No. Test Location
Lift/
Elevation
Parking Lot Subgrade
1059 20' E of grid line A.5/1
1060 35' E of grid line A.7/1
1061 50' E of grid line A.3/1
19.2 103.8 -1/+3 95
Probe Water Dry Unit Dry Unit
Mat. Depth Content Weight Weight
No. (inches) (%) (pct') (% compaction)
At grade 1 6 18.7 103.7 100
At grade 1 6 19.4 102.9 99
At grade I 6 18.4 104.6 100+
Comments:
Test results on this report meet project specification.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method~ASTM D2922, ASTM D3017
Gauge ID:
'~' ""rte~d ~o ~/~/HiII & Wdk~nson
Field Results Repo )'.~an w ' ' '
Technician: Bradford T./R'engstorff
Repod Distribution: / HBC/Terr~c/~
___--L/
(1) Transwestern Commerc a SjCrvices (1) TechniStructures
(1) O'Brien & Assoc ~' (1) City of Coppell- Bldg Insp Reviewed by:
(1) Hill & Wilkinson LTD ~ (1) City of Coppell - Constr Insp Eugene HaYbour
(2) Carter & Burgess Inc i (1) HBC Engineering Inc Principal
The tests were performed~jln general' accordance' with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1