PA9702-LR 991109CONCRETE COMPR SIVE STRENGTH TEL L ENGINEERINO, INC. 8901 Carpenter Frwy., Suite #100 Dallas, Tens 7S247 Date of Service: 10/29/1999 Report No.: 9929192 Report Date 11/09/1999 Client No.: COPPELL Project No.: 94991118 Client: City of Co pell Project: Coppell Aquatic/Recreation Ctr Attn: BraXPReid 30OBlockofParkwayBlvd 732 DeForest Coppell TX 75019 Coppell, Texas/Prj. #96051 Services: ~btainsamp~es~ffreshc~ncreteatthep~acement~~cati~ns~perf~rmrequired~e~dtestandcast compressive strength samples. PROJECT DATA CONTRACTOR: Hisaw & Assoc. CONCRETE CLASS: N/A CONCRETE SUPPLIER: Nelson Brothers PLACEMENT DATE: 10/29/1999 BATCH TIME: l:35pm PLANT: 1 TIME SAMPLED: 2:00pm BY: Greg Dimock SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Cloudy STRENGTH: 3000 psi @ 28 Days TEMPERATURE (F) - AIR 71 F CONCRETE: 75 P SLUMP: 5,0" Max TRUCK NO: 711 TICKET NO: 79487 Am: N/A AmCONTENT(~): N/A UNITWEIGHT(per): N/A TEST METHOD: ASTM C- 143 pLACEMENT LOCATION: Pool botlom, mechanical pit floor ASTM C-172 ASTM C-39 SAMPLE LOCATION: Pool bottom REPORT OF TESTS ACCUMULATIVE YARDS: 10 CYLINDER MEASURED MAXIMUM COM~RESSIVE MARKED SLUNIP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (p~i) TYPE 1 1 5.00 11/05/1999 7 91360 3230 1 2 5.00 11/05/1999 7 96960 3430 Average 3330 1 3 5.00 11/26/1999 28 1 4 5.00 11/26/1999 28 Sampled from truck. Technician: Greg Dimock Started: 12:30pm Finished: 3:00pm ~ ~ring, Inc. Report Distribution: (1) City of Coppell (1) City of Coppell - Engineering (1) BrinkIcy Sargent Architects (1) City of Coppell - Bldg. Insp. Eugene Harbour (1) Turner Engineers ( 1 ) City of Coppell - Leisure Serv Dept Vice President (1) Hisaw & Associates This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 0ILL Page 1 of I