Loading...
Amberpoint BP 2-LR030320CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0249 Service Date: February 18, 2003 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date: Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 'll'erracan 8901 Carpenter FnNy, Ste #100 Dallas, Texas 75247 (214) 630-1010 March 20, 2003 Material Information Specified Strength: 4000 psi (~ 28 Days Batch Time: 10:40am Plant: 2 Supplier: Potter Concrete Truck No: 104 Mix I.D. No.: 7753 Water Added Onsite Before Test: 15 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Ticket No: 113505 Sample Information sample Time: 11:05am Date Cast: February 18, 2003 Technician: Jose A. Martinez Weather Conditions: Cloudy Accumulative Yards: 20 Placement Method: Direct Discharge Sample Locations: See placement location Placement Location: Paving, SE corner of building (See attached sketch) Result Specification Test Method 5.00 4-5 ASTM C-143 7.0 4-8 ASTM C-231 64 ASTM C1064 60 ASTM C-1064 Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 1 1 6.00 28.27 02/25/2003 1 2 6.00 28.27 02/25/2003 1 3 6.00 28.27 03/18/2003 1 4 6.00 28.27 03/18/2003 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 102,850 3,640 7 109,520 3,870 Average 3,760 28 136,410 4,820 28 136,860 4,840 Average 4,830 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Jose A. Martinez Report Distribution: (1) Transwestem Commercial Services (1) O'Brien & Assoc (1) Hi[[& Wilkinson LTD (1) TechniStructures (2) Carler & Burgess Inc (1) City o( Coppell - Bldg Insp (1) City of Coppe[I - Constr insp (1) Staples Reviewed by: HBCfTerracon Eugen Hair.ur Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. ,,~Lw~.~-, Page 1 of 1 PROJECT: .--~"~'~' ~1'6~ JOB NO. O~ ~.1 o-~,~:~ %o,o~.~¢I Date Comp. By ll'err can Page of CHECKED BY: ¢_ .fl c) Form 112--5-93 CONCRETE COMPRESSIVE STRENGTH TEST ~ "Z ~" '~, ~ Report Number: 94021380.0248 'l['-rracon 8901 Carpenter FnNy, Ste #100 Service Date: February 18, 2003 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 ~:~ L ~,~te: P rojec~"~a pies J ~. l~.,l..~point Coppell, TX Project Number: 94021380 March 20, 2003 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 6:53am Plant: 1 Supplier: Potter Concrete Truck No: 102 Mix I.D. No.: 9349 Water Added Onsite Before Test: 10 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 4.75 1.8 4.7 47 Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28~27 1 2 6.00 28.27 1 3 6.00 28.27 1 4 6.00 28.27 Ticket No: 113499 Sample Information Sample Time: 7:20am Date Cast: February 18, 2003 Technician: Jose A. Martinez Weather Conditions: Cloudy Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: From Lines H to H.5 Placement Location: Slab Leaveouts on Line 1 from Lines H thru S Specification Test Method 4-5 ASTM C-143 N/A ASTM C-231 ASTM C1064 ASTM C-1064 Date Tested 02/25/2003 02/25/2003 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 03/18/2003 03/18/2003 7 130,660 4,620 7 131,120 4,640 Average 4,630 28 156,230 5,530 28 169,430 5,990 Average 5,760 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the strength samples. Technician: Jose A. Martinez Report Distribution: (1) Transwestern Commercial Services (1) O'Brien & Assoc (1) Hill & Wilkinson LTD (1) TechniStructures place (2) Carter & Burgess lnc (1) City of Coppell - Bldg Insp (1) City o~' Coppell - Constr Insp (1) Staples Inc ~s, perform required field tests and cast compressive Reviewed by: HBC/Te~ Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 ol' 1 ~-LLW~,O~-F~,,~,~