Loading...
Amberpoint BP 2-LR030314CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0248 Service Date: February 12, 2003 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date: Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 'lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 March 14, 2003 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 7:09am Plant: 1 Supplier: Potter Concrete Truck No: 107 Mix I.D. No.: 7753 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter No. ID 1 1 1 2 Result 4.00 7.0 57 55 Ticket No: 113484 Sample Information Sample Time: 7:55am Date Cast: February 12, 2003 Technician: Jose A. Martinez Weather Conditions: Clear Accumulative Yards: 20 Placement Method: Direct Discharge Sample Locations: 15' from bldg. & 5' E Placement Location: At NE end, ramp into building (See attachment) Specification Test Method 4-5 ASTM C-143 4-8 ASTM C-231 ASTM C1064 ASTM C- 1 O64 Area Date (inches) (sq. inches) Tested 6.00 28.27 02/19/2003 6.00 28.27 02/19/2003 1 3 6.00 28.27 03/12/2003 1 4 6.00 28.27 03/12/2003 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 115,350 4,080 7 115,580 4,090 Average 4,090 28 140,700 4,980 28 138,600 4,900 Average 4,940 Comments: 'Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the ~lient indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0253 Service Date: March 5, 2003 'lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date: Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 March 14, 2003 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 8:48am Plant: On-Site Supplier: Potter Truck No: 109 Ticket No: Mix I.D. No.: 7758 Sample Information Sample Time: 8:54am Date Cast: March 5, 2003 Technician: Terry L. Smith Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: On side of bldg., 20' E of W corner Placement Location: Sidewalk Field Test Data Test Result Specification Test Method Slump, inches: 5.50 ASTM C-143 Air Content, %: 1.0 ASTM C-231 Concrete Temperature,° F: 53 ASTM C1064 Ambient Temperature, o F: 46 ASTM C-1064 Plastic Unit Weight, pcf: 141.0 ASTM C-138 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 03/12/2003 7 76,410 2,700 I 2 6.00 28.27 03/12/2003 7 69,190 2,450 Average 2,580 1 3 04/02/2003 28 1 4 04/02/2003 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Terry L. Smith Repot[ Distribution: (1) Transwestern Commercial Services (1) O'Brien & Assoc (1) Hill & Wilkinson LTD (1) TechniStructures (2) Carter & Burgess Inc (1) City o1' Coppell - Constr Insp Reviewed by: (1) City o1' Coppell - Bldg Insp E'~gene Harbour (1) State Farm insurance Co Principal The tests were performed in general accordance w~th applicable ASTM, AASHTO, or DOT test methods, This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the wdtten approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical mateda[s. Page 1 of 1 0~-~LW~O,-.~,o CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0246 Service Date: February 12, 2003 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date: Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 March 14, 2003 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 10:20am Plant: 1 Supplier: Potter Concrete Truck No: 113 Mix I.D. No.: 7753 Ticket No: 113494 Sample Information Sample Time: 10:43am Date Cast: February 12, 2003 Technician: Jose A. Martinez Weather Conditions: Clear Accumulative Yards: 110 Placement Method: Direct Discharge Sample Locations: 10' S & 10' W of genrator pad Placement Location: South end leaveout pathing by generator pad Field Test Data Test Result Specification Test Method Slump, inches: 5.00 4-5 ASTM C-143 Air Content, %: 6.9 4-8 ASTM C-231 Concrete Temperature, o F: 64 ASTM C1064 Ambient Temperature, o F: 66 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 2 1 6.00 28.27 02/19/2003 2 2 6.00 28.27 02/19/2003 2 3 6.00 28.27 03/12/2003 2 4 6.00 28.27 03/12/2003 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 94,800 3,350 7 98,140 3,470 Average 3,410 28 119,500 4,230 28 121,160 4,280 Average 4,260 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Jose A. Martinez Report Distribution: (1) Transwestern Commercial Services (1) O'Brien & Assoc (1) Hill & Wilkinson LTD (1) TechniStructures (2) Carter & Burgess Inc (1) City of Coppell - Constr Insp (1) City ol Coppell - Bldg Insp (1) State Farm insurance Co Reviewed by: HBC/T,~~ Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2