Amberpoint BP 2-LR030318FIELD DENSITY TESTING Report Number: 94021380.0252 Service Date: March 4, 2003 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 lrerracun 8901 Carpenter FnNy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: Project: Staples 201 Northpoint Coppell, TX March 18, 2003 Project Number: 94021380 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Proiect Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pcf) (%) (% compaction) 1. 213800009 ASTM D 698 Lt brown silty clay 19.2 103.8 -1/+3 Field Test Data Probe Water Dry Unit Test Lift/ Mat. Depth Content Weight No. Test Location Elevation No. (inches) (%) (pcf) Sidewalk 1062 2' S of grid line N6 at Grade 1 6 18.7 99.2 1063 2' S of grid line N8 at Grade 1 6 19.4 99.7 1064 2' S of grid line N10 at Grade 1 6 20.6 100.4 1065 2' N of grid line J/2 at Grade 1 6 18.3 101.2 1066 2' N of gdd line J/3.5 at Grade 1 6 20.4 99.6 95 Dry Unit Weight (% compaction) 96 96 97 97 96 Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Gauge ID: Field Results Reported To: Contractor Technician: Bradford T. Rengstorff Report Distribution: (1) Transwestern Commercial Services (2) Carter & Burgess Inc (1) O'Bden & Assoc (1) City of Coppell - Bldg Insp (1) Hill & V~lkinson LTD (1) City of Coppell - Constr Insp (1) TechniStmctures (1) Staples Inc Reviewed by: HBC/T~acon Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, A,ASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1