Amberpoint BP 2-LR030310CONCRETE COMPRESSIVE STRENGTH TEST ~. ~/i , ~,'~:;)'..~ ~ lrerracon Report Number: g4021380.024'1 ./"~ ~ 8gol Carpenter Frw~ Service Date: February 10, 2003 ~'tl ~ Dallas, Texas 75247 (214) 630-1010 Client: Transwestem Commercial Services t~Date: March 10, 2003 Attn: James Gaspard Projec ;,01 North 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Coppell, TX 8901 Carpenter Frwy, Ste #100 Project Number: 94021380 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 8:22am Plant: 1 Supplier: Potter Concrete Truck No: 104 Mix I.D. No.: 9349 Water Added Onsite Before Test: 10 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Set No. ID 1 1 1 2 Specimen Diameter Ticket No: 113472 Sample Information Sample Time: 8:58am Date Cast: February 10, 2003 Technician: Jose A. Martinez Weather Conditions: Cloudy Accumulative Yards: 10 Placement Method: Sample Locations: From G.L. B thru C Placement Location: Slab leaveout on G.L.1 thru G.L.H thru A except on where hydraulic pads are Result Specification Test Method 4.00 4-5 ASTM C-143 1.9 N/A ASTM C-231 55 ASTM C1064 43 ASTM C-1064 1 3 I 4 Age at Maximum Compressive Area Date Test Load Strength (inches) (sq. inches) Tested (days) (lbs) (psi) 6.00 28.27 02/17/2003 7 138,550 4,900 6.00 28.27 02/17/2003 7 134,840 4,770 Average 4,840 6.00 28.27 03/10/2003 28 161,860 5,720 6.00 28.27 03/10/2003 28 164,240 5,810 Average 5,770 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the pl~,Cement locations, perform required field tests and cast compressive strength samples. Technician: Jose A. Martinez Report Distribution: (1) Transwestern Commercial Services (1) O'Brien & Assoc (1) Hill & Wilkinson LTD (2) Carter & Burgess Inc (1) TechniStructures (1) City of Coppell - Constr Insp (1) City of Coppe[I - Bldg Insp (1) State Farm Insurance Co Reviewed by: H B C/Te r~..~ Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in fulJ without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Pa.qe 1 of 1 01'LLW/~01'FL~i~e~eY