Amberpoint BP 2-LR030306CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021380.0234
Service Date: February 5, 2003
Client: Transwestern Commercial Services
Attn: James Gaspard
5001 Spring Valley Rd Ste 600 W
Dallas TX 75244
Report Date:
Project: Staples
201 Northpoint
Coppell, TX
Project Number: 94021380
lrerr can
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Mamh 06, 2003
Material Information
Specified Strength: 4000 psi @ 28 Days
Batch Time:
Supplier: Hanson
Truck No: 923
Mix I.D. No.: 9349
Plant: 27
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature,° F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Ticket No: 472592
Sample Information
Sample Time: 8:50am Date Cast: February 5, 2003
Technician: Jose A. Martinez
Weather Conditions: Cloudy
Accumulative Yards: 10
Placement Method: Direct Discharge
Sample Locations: See placement location
Placement Location: Block out on G.L. 11 columns Diamond's
mezzanine area
(See attached sheets)
Result Specification Test Method
5.00 4-5 ASTM C-143
3.2 N/A ASTM C-231
58 ASTM Cl 064
55 ASTM C-1064
Laboratory Test Data Age at Maximum Compressive
Set Specimen Diameter Area Date Test Load Strength
No. ID (inches) (sq. inches) Tested (days) (lbs) (psi)
I 1 6.00 28.27 02/12/2003 7 137,000 4,840
1 2 6.00 28.27 02/12/2003 7 134,750 4,770
Average 4,8~10
1 3 6.00 28.27 03/05/2003 28 175,430 6,200
1 4 6.00 28.27 03/05/2003 28 165,490 5,850
Average 6,030
Comments: Not tested for plastic unit weight.
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
Page 1 of 4
CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021380.0234
Service Date: February 5, 2003
ll'erracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Client: Transwestern Commercial Services
Attn: James Gaspard
5001 Spring Valley Rd Ste 600 W
Dallas TX 75244
Report Date:
Project: Staples
201 Northpoint
Coppell, TX
Project Number: 94021380
March 06, 2003
Material Information
Specified Strength: 4000 psi @ 28 Days
Batch Time: 8:59am Plant: 27
Supplier: Hanson
Truck No: 1015
Mix I.D. No.: 9349
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature,° F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Ticket No: 472599
Sample Information
Sample Time: 9:38am Date Cast: February 5, 2003
Technician: Jose A. Martinez
Weather Conditions: Cloudy
Accumulative Yards: 30
Placement Method: Pump
Sample Locations: Between G.L. A & 3.9 to 3
Placement Location: First floor mezzanine
Result Specification Test Method
5.00 4-5 ASTM C-143
2.6 N/A ASTM C-231
57 ASTM Cl 064
55 ASTM C-1064
Laboratory Test Data
Age at Maximum Compressive
Set Specimen Diameter Area Date Test Load Strength
No. ID (inches) (sq. inches) Tested (days) (lbs) (psi)
2 1 6.00 28.27 02/12/2003 7 143,990 5,090
2 2 6.00 28.27 02/12/2003 7 141,030 4,990
Average 5,040
2 3 6.00 28.27 03/05/2003 28 176,760 6,250
2 4 6.00 28.27 03/05/2003 28 176,870 6,250
Average 6,250
Comments: Not tested for plastic unit weight.
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in fult without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 2 of 4 01'LLW/ROI'FubJce Key
CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021380.0234
Service Date: February 5, 2003
'irerracan
8901 Carpenter Fnvy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Client: Transwestern Commercial Services
Attn: James Gaspard
5001 Spring Valley Rd Ste 600 W
Dallas TX 75244
Report Date:
Project: Staples
201 Northpoint
Coppell, TX
Project Number: 94021380
March 06, 2003
Material Information
Specified Strength: 4000 psi @ 28 Days
Batch Time: Plant: 27
Supplier: Hanson
Truck No: 648
Mix I.D. No.: 9349
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature, o F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Laboratory Test Data
Result
4.75
2.2
6O
49
Set Specimen Diameter Area
No. ID (inches) (sq. inches)
3 1 6.00 28.27
3 2 6.00 28.27
3 3 6.00 28.27
3 4 6.00 28.27
Ticket No: 499630
Sample Information
Sample Time: 1:30pm Date Cast: February 5, 2003
Technician: Jose A. Martinez
Weather Conditions: Cloudy
Accumulative Yards:
Placement Method:
Sample Locations:
Placement Location:
120
Direct Discharge
Hydraulic Pads to Diamond's
Blockout around elevator pit generator pad
Diamond's on A.5
Sample location: Hydraulic pads &
Diamonds 1.5/2.0/2.513.013.513.9, G.L.B
Specification
4-5
N/A
Test Method
ASTM C-143
ASTM C-231
ASTM C1064
ASTM C-1064
Date
Tested
02/12/2003
02/12/2003
03/05/2003
03105/2003
Age at Maximum Compressive
Test Load Strength
(days) (lbs) (psi)
7 132,830 4,700
7 136,870 4,840
Average 4,770
28 171,020 6,050
28 164,620 5,820
Average 5,940
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 3 of 4 01-LLW/R01-Fulur.
lrerracan
.CONCRETE COMPRESSIVE STRENGTH TEST
Client: Transwestern Commercial Services Project Number:94021380
Report Number: 94021380.0234
Comments (cont'd):
Comments: Not tested for plastic unit weight.
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Jose A. Martinez
Repod Distribution:
(1) Transwestern Commercial Services
(1) O'Brien & Assoc
(1) Hill & Wilkinson LTD
(1) TechniStructures
(2) Carter & Burgess Inc
(1) City of Coppell - Constr Insp
(1) City of Coppell - Bldg Insp
(1) State Farm Insurance Co
Reviewed by:
Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repod is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicab]e
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.