Amberpoint BP 2-LR030306CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0234 Service Date: February 5, 2003 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date: Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 lrerr can 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Mamh 06, 2003 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: Supplier: Hanson Truck No: 923 Mix I.D. No.: 9349 Plant: 27 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Ticket No: 472592 Sample Information Sample Time: 8:50am Date Cast: February 5, 2003 Technician: Jose A. Martinez Weather Conditions: Cloudy Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: See placement location Placement Location: Block out on G.L. 11 columns Diamond's mezzanine area (See attached sheets) Result Specification Test Method 5.00 4-5 ASTM C-143 3.2 N/A ASTM C-231 58 ASTM Cl 064 55 ASTM C-1064 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) I 1 6.00 28.27 02/12/2003 7 137,000 4,840 1 2 6.00 28.27 02/12/2003 7 134,750 4,770 Average 4,8~10 1 3 6.00 28.27 03/05/2003 28 175,430 6,200 1 4 6.00 28.27 03/05/2003 28 165,490 5,850 Average 6,030 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical Page 1 of 4 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0234 Service Date: February 5, 2003 ll'erracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date: Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 March 06, 2003 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 8:59am Plant: 27 Supplier: Hanson Truck No: 1015 Mix I.D. No.: 9349 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Ticket No: 472599 Sample Information Sample Time: 9:38am Date Cast: February 5, 2003 Technician: Jose A. Martinez Weather Conditions: Cloudy Accumulative Yards: 30 Placement Method: Pump Sample Locations: Between G.L. A & 3.9 to 3 Placement Location: First floor mezzanine Result Specification Test Method 5.00 4-5 ASTM C-143 2.6 N/A ASTM C-231 57 ASTM Cl 064 55 ASTM C-1064 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 1 6.00 28.27 02/12/2003 7 143,990 5,090 2 2 6.00 28.27 02/12/2003 7 141,030 4,990 Average 5,040 2 3 6.00 28.27 03/05/2003 28 176,760 6,250 2 4 6.00 28.27 03/05/2003 28 176,870 6,250 Average 6,250 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in fult without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 4 01'LLW/ROI'FubJce Key CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0234 Service Date: February 5, 2003 'irerracan 8901 Carpenter Fnvy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600 W Dallas TX 75244 Report Date: Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 March 06, 2003 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: Plant: 27 Supplier: Hanson Truck No: 648 Mix I.D. No.: 9349 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 4.75 2.2 6O 49 Set Specimen Diameter Area No. ID (inches) (sq. inches) 3 1 6.00 28.27 3 2 6.00 28.27 3 3 6.00 28.27 3 4 6.00 28.27 Ticket No: 499630 Sample Information Sample Time: 1:30pm Date Cast: February 5, 2003 Technician: Jose A. Martinez Weather Conditions: Cloudy Accumulative Yards: Placement Method: Sample Locations: Placement Location: 120 Direct Discharge Hydraulic Pads to Diamond's Blockout around elevator pit generator pad Diamond's on A.5 Sample location: Hydraulic pads & Diamonds 1.5/2.0/2.513.013.513.9, G.L.B Specification 4-5 N/A Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 Date Tested 02/12/2003 02/12/2003 03/05/2003 03105/2003 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 132,830 4,700 7 136,870 4,840 Average 4,770 28 171,020 6,050 28 164,620 5,820 Average 5,940 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 4 01-LLW/R01-Fulur. lrerracan .CONCRETE COMPRESSIVE STRENGTH TEST Client: Transwestern Commercial Services Project Number:94021380 Report Number: 94021380.0234 Comments (cont'd): Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Jose A. Martinez Repod Distribution: (1) Transwestern Commercial Services (1) O'Brien & Assoc (1) Hill & Wilkinson LTD (1) TechniStructures (2) Carter & Burgess Inc (1) City of Coppell - Constr Insp (1) City of Coppell - Bldg Insp (1) State Farm Insurance Co Reviewed by: Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repod is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicab]e to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 4