Loading...
Freeport NIP(7.0)-LR030324:RoneEngineerS 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (214) 630-9819 (fax) REPORT OF WATER INJECTION INSPECTION Client: Duke Realty Services, LP Arm: Mr. JeffLangston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Freeport 10 500 Freeport Parkway C~ppell, TX Services: Water Injection Inspection Report No.: 173152 Project No.: 037333 Date of Service: 03/21/2003 Report Date: 03/24/2003 Report of Inspection On this date, a Rone Engineers, Ltd. representative(s) was on site to perform Water Injection Inspection. The results are attached. Technician Time: Page 1 of 3 Technician: Lanny Gist Report Distribution: (1) Duke Realty Servieea, LP (1) Duke Realty Services, LP ( 1 ) City of Coppell Engineering Dept. (1) Pacheco Koch Consulting Engineers 6:30 a.m. - 4:00 p.m. (1) Engineering Analyst (1) City of Coppell Engineering Dept. K. Scott Watson CMT Operations Manager LiMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject ma~er provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 99DD Pat, e 1 of 1 WATER INJECTION OBSERVATION Client: Duke Realty Services, LP Report No.: 173152 Project No.: 037333 Project: Freeport 10 Date of Service: 3/21/2003 500 Freeport Parkway Page 2 of 3 -- DESCRIPTION/EXPLANATION YES NO N/A 1. Specific gravity of lime was checked and found to be 1.14 and 1.17 X 2. Lime slurry was continuously a~litated X 3. Surfactant was added to each load X 4. The injection pressure was kept between 50 to 100 psi at point of injection x 5. intervals of 12" were achieved durin~l injection process until refusal X 6. Total depth of iniection - 10 feet X 7. Max. spacing of iniection probes was recorded to be 5 ft. X 8. Free lime on surface X 9. Square feet iniected on this date 140,000 :10. Location of injection Building pad 4-D Remarks: completed 5th pass, began 6th pass See attached for sketch of injected area, pass number for each area, dimension of injection area, and amount of lime used on this date. Time: 6:30 a.m. - 4:00 p.m. Technician: L. Gist LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the wdtten approval of Rone Engineers, Inc. RO ,neers 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (214) 630-9819 (fax) REPORT OF WATER INJECTION INSPECTION CHent: Duke Realty Services, LP At'm: Mr. JeffLangston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Freeport 10 500 Freeport Parkway C~ppeil, TX Services: Water Injection Inspection Report No.: 173062 Project No.: 037333 Date of Service: 03/20/2003 Report Date: 03/24/2003 Report of Inspection On this date, a Rone Engineers, Ltd. representative(s) was on site to perform Water Injection Inspection. The results are attached. Technician Time: Page 1 of 3 Technician: Lanny Gist Report Distribution: (1) Duke Realty Services, LP (1) Duke Realty Services, LP (1) City of Coppell Engineering Dept. (I) Paeheco Koch Consulting Engineers 6:30 a.m. - 5:00 p.m. (1) Engineering Analyst (1) City of Coppell Engineering Dept. CMT 0 lcott Watson )erations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appesranee, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 99DD PaRe 1 of 1 WATER INJECTION OBSERVATION Client: Duke Realty Services, LP Report No.: 173062 Project No.: 037333 Project: Freeport 10 Date of Service: 3/20/2003 500 Freeport Parkway Page 2 of 3 -. DESCRIPTIO N/EXP LANATION YES N O N/A 1. Specific gravity of lime was checked and found to be 1.14 and 1.17 X 2. Lime slurry was continuously agitated X 3. Surfactant was added to each load X 4. The injection pressure was kept between 50 to 100 psi at point of injection x 5. Intervals of 12" were achieved during injection process until refusal X 6. Total depth of iniection - 10 feet x 7. Max. spacing of injection probes was recorded to be 5 ft. X 6. Free lime on surface X 9. Square feet injected on this date 146,250 10. Location of injection Building pad 4-D Remarks: completed 4th pass, began 5th pass See attached for sketch of injected area, pass number for each area, dimension of injection area, and amount of lime used on this date. Time: Technician: 6:30 a.m. - 5:00 p.m. L. Gist LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. RoneEn gineers 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: Duke Realty Services, LP Attn: Mr. JeffLangston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Report No.: 172835 Project No.: 037333 Date of Service: 03/14/2003 Report Date: 03/24/2003 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of flesh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Hanson PLANT: 29 SPECIFICATION REQUIREMENTS STRENGT}I: 3000 psi ~ 28 Days SLUMP On): 5" maximum AIR (%): TEST METHOD: 3% - 6% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 MIX DESIGN I.D.: 9375 PLACEMENT DATE: 03/14/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 3:20pm BATCH T~Mg: NA TEMPERATURE ~) - AIR 74 P CONCRETE: 66 TRUCKNO: 8 TICKET NO: 321420 AIR CONTENT (%): 3.5 UNIT WEIGHT (pct'): ~xTA OVERALL PLACEMENT LOCATION: Headwall - Station 0+00, storm line 4 SAMPLE LOCATION: Entire headwall REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MARKED SET NO. 1 1 1 2 I 3 1 4 MEASURED MAXIMUM SLUMP DATE AGE LOAD (inches) TESTED (days) (lbs. force) 2.00 2.00 2.00 2.00 Technician: Lanny Gist Report Distribution: (1) Duke Realty Services, LP (1) Duke Realty Services, LP (1) City of Coppell Engineering Dept. (1) Potter Concrete 03/21/2003 7 04/11/2003 28 04/11/2003 28 05/09/2003 56 142485 Started: 3:00pm Finished: 5:00pm (l) Pacheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Engineering Dept. COMPRESSIVE STRENGTH FRACTURE (psi) TYPE 5040 Unbonded Cap Unbonded Cap Unbonded Cap K. Scott Watson CMT Operations Manager Llnbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written appmvaI of Rone Engineers, Ltd. 01DK Page 1 of 1