Loading...
Freeport NIP(7.0)-LR030318RoneEn gi 8908 Ambassador Row Dallas, Texas 7524%4510 (214) 630-9745 (214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: Duke Realty Services, LP Attn: Mr. JeffLangston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Report No.: 172472 Project No.: 037333 Date of Service: 03/10/2003 Report Date: 03/18/2003 Project: Services: Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of flesh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA CONTe. nCTOR: Duke Realty Services, LP CONCRETE SUPPLIER: HansoD PLANT: 29 SPECIFICATION REQUIREMENTS STRENGTH: 3000 psi ~ 28 Days SLUMP (in): 5" maximum AIR (%): TEST METHOD: 3% - 5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 M1XDESIGN I.D.: 9375 PLACEMENT DATE: 03/10/2003 WEATHER CONDITIONS: Overcast TIME SAMPLED: 2:50pm BATC}t TIME: 2:20pm TEMPERATURE (IF) - AIR 58 F CONCRETE: 56 F TaUCK NO: 103 TlCKET NO: 321227 AIR CONTENT (%): 4.0 UNIT WEIGHT (per): NA OVERALL PLACEMENT LOCATION: Headwall, storm drain, Line 1, Station 0+00 SAMPLE LOCATION: Entire headwall REPORT Ol~ TERTR Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MARKED SLUMP SET NO. (inches) 1 1 3.50 MAXIMUM DATE AGE LOAD TESTED (days) Obs. force) 03/17/2003 7 125760 COMPRESSIVE STRENGTH FRACTURE (psi) TYPE 4450 Unbonded Cap 1 2 3.50 1 3 3.50 04/07/2003 28 04/07/2003 28 Unbonded Cap Unbonded Cap 1 4 3.50 05/05/2003 56 Unbonded Cap On 03/11/2003, with Duke was notified. test specimens were struck by Cal Har Construction truck, Mike Cox Started: 3:00pm Finished: 5:00pm (1) Pacheco Koch Consulting Engineers (1) Engineering Analyst (I) City of Coppell Engineering Dept. Technician: Lanny Gist Report Distribution: (1) Duke Realty Services, LP (1) Duke Realty Services, LP (1) City of Copp¢ll Engineering Dept. (1) Potter Concrete K. Scott Watson CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval o f Rone Engineers, L~. 01DK Page 1 of 1