Loading...
St Joseph-LR030314CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0232 Service Date: February 13, 2003 Client: St Joseph Village inc Attn: Joseph Dingman 13223 Glad Acres Dr Dallas TX 75234 'lrerracan 8901 Carpenter Fro/y, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: March 14, 2003 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX Project Number: 94021187 Ma terial In formation Specified Strength: 3000 psi @ 28 Days Batch Time: 9:50am Supplier: Hanson Truck No: 103 Mix I.D. No.: 7775 Plant: 29 Field Test Data Test Ticket No: 319574 Sample Information sample Time: 10:40am Date Cast: February 13, 2003 Technician: Christopher W. Eubanks Weather Conditions: Cloudy Accumulative Yards: 20 Placement Method: Direct Discharge Sample Locations: Stadeaf Street Curb Placement Location: Statical Street Curb & Sidewalk Sta. 2+00 to Sta. 4+19; N side Approach, S Bound Right Turn Lane Result Specification Test Method 5.25 3-5 ASTM C-143 7.2 3-6 ASTM C-231 60 ASTM C1064 64 ASTM C-1064 Slump, inches: Air Content, %: Concrete Temperature? F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 I 6.00 28.27 02/20/2003 7 129,550 4,580 1 2 6.00 28.27 02/20/2003 7 124,950 4,420 Average 4,500 1 3 6.00 28.27 03/13/2003 28 159,360 5,640 1 4 6.00 28.27 03/13/2003 28 159,240 5,630 Average 5,640 Comments: Not tested for plastic unit weight....% ~. ~ T~-~.'%.-- F % Services- Obtain samples of fresh concrete at the placement locations, perform required field$.C~,~.~a.ea~..~l~.essive strength samples. / ~/' ~ ~ ~ LYNDON J. COX ,,,~'.. /. ~..'~= Technician: Christopher W. EMbanks ............ Repo~ Distribution: ~ HBC~e~acon~ (1) S Joseph Village Inc (1) Aguirre Corperation /J ~ ~ ~_ (~) c~ntex con~truction ¢) St~d¢.ws ~n.ge~n~ S.~ices Reviewed by: [~4~ .... ~ · ~ (1) Ci~ of Coppe[I Engineering (1) St Andr~s Management Se~ic~ ~ - Lyndon J. ~o~, P.E. (I) Cdy et Coppell Bidg Insp ' ' ~ Principal ~ineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repo~ is exclusively for the ~e of the client indicated above and shall not be reproduced except in full without the wriffen approval of Terracon. Test results tmnsmiff~ herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the prope~ies of other apparently similar or identicat materials. Page 1 of 1