St Joseph-LR030224CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021187.0213
Service Date: January 25, 2003
Client: St Joseph Village Inc
Attn: Joseph Dingman
13223 Glad Acres Dr
Dallas TX 75234
'l['erracon
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Report Date: February 24, 2003
Project: St. Joseph Village
1201 East Sandy Lake Rd
Coppell, TX
Project Number: 94021187
Material Information
Specified Strength: 3000 psi @ 28 Days
Batch Time: 7:03am Plant: 27
Supplier: Hanson
Truck No: 1090
Mix I.D. No.: 7750
Ticket No: 472317
Sample Information
Sample Time: 7:30am Date Cast: January 25, 2003
Technician: Christopher D. Harbour
Weather Conditions: Cold, overcast
Accumulative Yards: 90
Placement Method: Pump
Sample Locations: See Sketch.
Placement Location: Sidewalks between Cottage Bldgs. #1 thru
#6
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature,o F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Laboratory Test Data
Result
7.00
3.7
45
35
Set Specimen Diameter Area
No. ID (inches) (sq. inches)
1 1 6.00 28.27
1 2 6.00 28.27
1 3 6.00 28.27
1 4 6.00 28.27
Specification Test Method
3-5 ASTM C-143
3-6 ASTM C-231
ASTM C1064
ASTM C-1064
Age at Maximum Compressive
Date Test Load Strength
Tested (days) (Ihs) (psi)
02/01/2003 7 119,550 4,230
02/01/2003 7 124,000 4,390
Average 4,310
02/22/2003 28 160,830 5,690
02/22/2003 28 162,190 5,740
Average 5,720
Comments: Not tested for plastic unit weight.
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 2 0~.LW~,~,-r.~..K.~
CON'CRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021187.0213
Service Date: January 25, 2003
Client: St Joseph Village Inc
Attn: Joseph Dingman
13223 Glad Acres Dr
Dallas TX 75234
'll'erracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Report Date: February 24, 2003
Project: St. Joseph Village
1201 East Sandy Lake Rd
Coppell, TX
Project Number: 94021187
Material Information
Specified Strength: 3000 psi @ 28 Days
Batch Time: Plant: 27
Supplier: Hanson
Truck No: 1097 Ticket No: 472326
Mix I.D. No.: 7750
Water Added Onsite Before Test: 10 Gallons
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature,° F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Laboratory Test Data
Set Specimen Diameter
No. ID (inches)
2 1
2 2
Sample Information
Sample Time: 10:15am Date Cast: January 25, 2003
Technician: Christopher D. Harbour
Weather Conditions: Cold
Accumulative Yards: 90
Placement Method: Pump
Sample Locations: See Sketch.
Placement Location: Cottage Bldg. #9 Driveways
Result Specification Test Method
5.25 3-5 ASTM C-143
4.0 3-6 ASTM C-231
46 ASTM C1064
34 ASTM C-1064
Age at Maximum Compressive
Area Date Test Load Strength
(sq. inches) Tested (days) (lbs) (psi)
2 3
2 4
6.00 28.27 02/01/2003 7 119,890 4,240
6.00 28.27 02/01/2003 7 118,700 4,200
Average 4,220
6.00 28.27 02/22/2003 28 151,400 5,350
6.00 28.27 02/22/2003 28 150,410 5,320
Average 5,340
Comments: Not tested for plastic unit weight.
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
~ p....' ~ '..~.,,,
Technician: Christopher D. Harbour
RepodDistribution: ~//1~ HBC/T~aco~/
(1) St Joseph Village thc (1) Aguirre Cor~ration
(1) Ci~ of CoppeH Engineering (1) St Andrews Management Se~ices ~ Lyndon J.~C~x, P.E.
(1) City of Coppe[l - Bldg Insp PrincipaljE~gineer
The tests were pedo~ed in general accordance wi~ applicable ASTM, ~SHTO, or DOT test methods. This repoA is exclusively ~ the use of the client
indicated above and shall not be reproduced except in full without the written approva( of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location{s) referenced and are not necessarily indicative of the propedies of other apparently similar or identical
materials.
Page 2 of 2 ~'~'~'"~
!
.!
%,..