Loading...
St Joseph-LR030217CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0211 Service Date: January 18, 2003 Client: St Joseph Village Attn: Joseph Dingman 13223 Glad Acres Dr Dallas TX 75234 'l['erracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: February 17, 2003 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX Project Number: 94021187 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 9:57am Supplier: Hanson Truck No: 923 Mix I.D. No.: 7750 Plant: 27 Field Test Data Test Ticket No: 472220 Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Sample Information Sample Time: 10:34am Date Cast: January 18, 2003 Technician: Marie R. Villanueva Weather Conditions: Clear Accumulative Yards: 40 Placement Method: Pump Discharge Sample Locations: NE cot. of Entrance Road Placement Location: Paving, Main Entrance Road @ N side over Box Culverts Result Specification Test Method 5.00 3-5 ASTM C-143 5.2 3-6 ASTM C-231 48 ASTM C1064 43 ASTM C-1064 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 01/21/2003 3 75,130 2,660 1 2 6.00 28.27 01/25/2003 7 105,550 3,730 1 3 6.00 28.27 02/15/2003 28 139,560 4,940 1 4 6.00 28.27 02/15/2003 28 143,060 5,060 Average 5,000 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 D~.LW,,O,-,~.K,y CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0211 Service Date: January 18, 2003 ']l'erracon 8901 Carpenter Frwy, Ste #100 Dallas. Texas 75247 (214) 630-1010 Client: St Joseph Village Inc Attn: Joseph Dingman 13223 Glad Acres Dr Dallas TX 75234 Report Date: February 17, 2003 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppeli, TX Project Number: 94021187 Material Information Specified Strength: 3000 psi @ 28 Days BatchTime: 11:12am Plant: 27 Supplier: Hanson Truck No: 1015 Mix I.D. No.: 7750 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature? F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.00 5.0 5O 45 Set Specimen Diameter Area No. ID (inches) (sq. inches) 2 1 6.00 28.27 2 2 6.00 28.27 2 3 6.00 28.27 2 4 6.00 28.27 Ticket No: 472229 Sample Information Sample Time: 11:38am Date Cast: January 18, 2003 Technician: Marlo R. Villanueva Weather Conditions: Clear Accumulative Yards: 130 Placement Method: Pump discharge Sample Locations: SW cor. of Entrance Road Placement Location: See page 1 Specification Test Method 3-5 ASTM C-143 3-6 ASTM C-231 ASTM C 1064 ASTM C- 1 O64 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 01/21/2003 3 70,030 2,480 01/25/2003 7 109,860 3,890 02/15/2003 28 131,900 4,660 02/15/2003 28 129,890 4,590 Average 4,630 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. £ ,-,::..-' .o .,~ -¢- ,.,~ ', 4. / ,,-, ~- ~, tcj 'c- .-' \",.-.- ' Technician: Marie R. Villanueva .e.ort is, i ut,o (t) S! Joseph Village Inc {1 ) Aguirre Corporation (1) Centex Construction (1) St Andrews Management Services Reviewed by: (1) City of Coppell Engineering (1) St Andrews Management Services ,~ Lyndon\J. Cox, P.E. (1) City of Coppell - Bldg Insp ~ Principl~lt Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusi~,e~, for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2