St Joseph-LR030107FIELD DENSITY TESTING
Report Number: 94021187.0197
Service Date: December 18, 2002
lrerracan
8901 Carpenter Fn,vy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Client: St Joseph Village Inc
Attn: Joseph Dingman
13223 Glad Acres Dr
Dallas TX 75234
Report Date: January 07, 2003
Project: St. Joseph Village
1201 East Sandy Lake Rd
Coppell, TX
Project Number: 94021187
Material Information Lab Test Data Project Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Material Laboratory Content Weight Range Unit Weight
No. Test Method Description and Classificaiion (%) (pcf) (%) (% compaction)
1.211870134 ASTM D 698 Brown silty clay (lime treated) 18.0 105.8 -1/+3 95
2.211870015 ASTM D 698 Dk brown & gray clay 20.9 101.5 -1/+3 95
Field Test Data Probe Water Dry Unit Dry Unit
Test Lift/ Mat. Depth Content Weight Weight
No. Test Location Elevation No. (inches) (%) (pcf) (% compaction)
Starleaf Street Subgrade
903 50' E of existing paving At Grade 1 6 19.7 101.2 96
904 150' E of existing paving At Grade 1 6 19.6 104.8 99
Cottage Driveways Subgrade
905 1133 At Grade 2 6 19.9 100.3 99
906 1135 At Grade 2 6 20.1 99.4 98
907 1139 At Grade 2 6 20.7 98.6 97
Comments:
Test results on this report meet project specification.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method:ASTM D2922, ASTM D3017
Gauge ID:
..- %\...- ~ ....,,~
Ff'ND01~ J. 60X
.........
Field Results Repoded To: Centex
Technician: Bradford T. Rengsto~
Repo~ Distribution: ~ HBC~errac~
(1) St Joseph Village Inc (1) AguiCe Cor~ration
(1) Centex Construction (1) St Andr~s Management Se~ices Reviewed by'. ~,..
(1) City of Coppell Engineering (1) St Andrews Management Se~ices '~ -[ Lyndon ~ Cox P E
The tests were pedormed in general accordance with applicable ASTM, ~SHTO, or DOT test methods. This repo~ is exclusi~¢~ for the use of the client
indicated above and shall not be reproduced except in tull without the written approval of Terracon. Test results transmitted herren are only applicable
to the actual samples tested at the location(s} referenced and are not necessarily indicative of the properties of other apparently similar or idenUcal
materials.
Page 1 of 1