St Joseph-LR021202CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0175 Service Date: October 31,2002 ']rerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: December 02, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3000 psi ~ 28 Days Batch Time: 8:00am Plant: 29 Supplier: Hanson Truck No: 1029 Mix I.D. No.: 7724 Ticket No: 320708 Sample Information Sample Time: 9:00am Date Cast: October 31,2002 Technician: Michael P. Ardito Weather Conditions: Cool, cloudy Accumulative Yards: 100 Placement Method: Direct Discharge Sample Locations: Sta. 5+00 Placement Location: Paving, Star Leaf Street @ Sra. 1+00 to Sra. 6+19 Field Test Data Test Result Slump, inches: 3.50 Air Content, %: 5.1 Concrete Temperature,o F: 65 Ambient Temperature, o F: 49 Plastic Unit Weight, pcf: Laboratory Test Data Specification Test Method 3-5 ASTM C-143 3-6 ASTM C-231 55 - 95 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 11/07/2002 7 133,110 4,710 1 2 6.00 28.27 11/07/2002 7 128,310 4,540 Average 4,630 1 3 6.00 28.27 11/28/2002 28 150,450 5,320 1 4 6.00 28.27 11/28/2002 28 155,320 5,490 Average 5,410 Services - Obtain samples of fresh concrete at the placement locations, perrorm required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the crient indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propedies of other apparently similar or identical materials. Page 1 of 3 e?~ ~..~ ,CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0175 Service Date: October 31,2002 'll'erracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247. (214) 630-1010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: December 02, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 9:16am Plant: 29 Supplier: Hanson Truck No: 923 Mix I.D. No.: 7724 Ticket No: 272283 Sample Information Sample Time: 10:30am Date Cast: October 31,2002 Technician: Michael P. Ardito Weather Conditions: Cool, cloudy Accumulative Yards: 200 Placement Method: Direct Discharge Sample Locations: Sra. 3+00 Placement Location: See page 1. Field Test Data Test Result Specification Test Method Slump, inches: 3.50 3-5 ASTM C-143 Air Content, %: 5.8 3-6 ASTM C-231 Concrete Temperature, o F: 66 55 - 95 ASTM C1064 Ambient Temperature, o F: 49 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 1 6.00 28.27 11/07/2002 7 134,600 4,760 2 2 6.00 28.27 11/07/2002 7 137,060 4,850 Average 4,810 2 3 6.00 28.27 11/28/2002 28 166,780 5,900 2 4 6.00 28.27 11/28/2002 28 173,060 6,120 Average 6,010 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repod is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 3 0~-~LW~0~-F~...~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0175 Service Date: October 31,2002 lr'erracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: December 02, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: Plant: 29 Supplier: Hanson Truck No: 1029 Mix I.D. No.: 7724 Ticket No: 320737 Sample Information Sample Time: 11:35am Date Cast: October 31,2002 Technician: Michael P. Ardito Weather Conditions: Cool, cloudy Accumulative Yards: 300 Placement Method: Direct Discharge Sample Locations: Sta. 1+00 Placement Location: See page 1. Field Test Data Test Result Specification Test Method Slump, inches: 3.50 3-5 ASTM C-143 Air Content, %: 5.6 3-6 ASTM C-231 Concrete Temperature,° F: 64 55 - 95 ASTM C1064 Ambient Temperature, o F: 51 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 1 6.00 28.27 11/07/2002 7 131,030 4,630 3 2 6.00 28.27 11/07/2002 7 130,900 4,630 Average 4,630 3 3 6.00 28.27 11/28/2002 28 163,710 5,790 3 4 6.00 28.27 11/28/2002 28 153,440 5,430 Average 5,610 Services - Obtain samples of fresh concrete at the placement locations, perform required field ~e.st'~'d.,~t~ compressive strength samples. .--%,,..... ~-....,j- ; LYNDON d. COX ~, ....~ .......................... :.-..-~ Technician: Michael P. Ardito Repod Distribution: ,,~ HBC~rrac~, (1) St. Joseph Village, Inc. (1) City of Coppell Engineering (1) Aguirre Corporation (1) St Andrews Management Reviewed by: (1) Cenlex- Jobsite (1) St Andrews Management f Lyndon J, ~ox, P.E. (1) City of Coppell - B]dg Insp /, Principal" -1 ]-i~ngineer / The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for th~se of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of ether apparently similar or identical materials. Page 3 of 3