Loading...
Trinity Shores-LR020722 GEOSCIENCE ENGINEERING & TESTING, INC. GEOTECHNICAL & MATERIALS ENGINEERS COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Ken-Ran Development 2125 N. Josey Lane, Suite 202 Carro[[ton, Texas 75006 DATE OF SERVICE: 07/22/02 PROJECT: Proposed 'Trinity Shore Estates" Sandy Lake Road Copper[, Texas REPORT NO. 02-DM857-18a CONTRACTOR: TICKET NO.: 3147686 AMBIENT TEMP. (°F): 98° CONCRETE TEMP. (°F): 79° TIME BATCHED: 2:56 pm TIME SAMPLED: 3:15 pm WEATHER CONDITION: Hot/Sunny Comment Concrete Cod CONCRETE SUPPLIER: PLANT/TRUCK: MIX ID NUMBER: WATER ADDED (gal): SLUMP (inches) (ASTM C-143) Lattimore Materials C 3/964 3,000 psi 10 4.5 LOCATION OF PLACEMENT: ManhoJe on Line A Next to 2~ Junction Box area CYLINDER AGE DATE J TOTAL COMPRESSIVE REQUIRED COMPRESSIVE NUMBER (days) TESTED J LOAD (lbs) STRENGTH (psi) STRENGTH (psi) 1 7 07/22/02 J 110,250 3,899 3000/28 Days 2 28 08/12/02 3 28 08/12/02 4 Hold Specifications: Making E Curfng: ASTM C-143 Testing Methods: ASTM C-143, ASTM 039 GE'T1 Technidan: Riga Renewed by: