St Joseph-LR030403CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0247 Service Date: March 4, 2003 Client: St Joseph Village Inc Attn: Joseph Dingman 13223 Glad Acres Or Dallas TX 75234 1 errrrrrr"r con 8901 Carpenter Frwy, Ste #100 t I Dallas, Texas 75247 (214) 630 -1010 St. Joseph Coppell, TX April 03, 2003 Lake Rd Project Numbe 94021187 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 7:00am Plant: 29 Supplier: Hanson Truck No: 80 Ticket No: 319741 Mix I.D. No.: 7750 Water Added Onsite Before Test: 20 Gallons Water Added Onsite After Test: 5 Gallons Field Test Data Sample Information Sample Time: 7:50am Date Cast: March 4, 2003 Technician: Christopher W. Eubanks Weather Conditions: Cloudy, windy Accumulative Yards: 40 Placement Method: Pump Sample Locations: Driveway in front of Cottage Bldg. 11 Placement Location: Paving- Driveways & Sidewalks in front of Cottage Bldgs. 11, 12 & 13 Test Result Specification Test Method Slump, inches: 5.75 3 -5 ASTM C -143 Air Content, %: 6.25 3 -6 ASTM C -231 Concrete Temperature,° F: 60 ASTM C1064 Ambient Temperature, a F: 42 ASTM C -1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) ( sq. inches Tested (days) (Ibs) (psi) 1 1 6.00 28.27 03/07/2003 3 77,740 2,750 1 2 6.00 28.27 03/11/2003 7 97,870 3,460 1 3 6.00 28.27 04/01/2003 28 121,670 4,300 1 4 6.00 28.27 04/01/2003 28 124,300 4,400 Average 4,350 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive �� a�eceacp� strength samples. .<< ftF T ,,..,, e r .* ......................... ....' LYNDON J. COX Technician: Christopher W. Eubanks ...... ............................... .c ��� A : bv�a0 1 � Report Distribution: HBC/ r I�cENSEn' Terracon (1) St Joseph Village Inc (1) St Andrews Management Services 4, c....••• '�(�� ee (1) Aguirre Corporation (1) City of Cappell TX `' p�' ^� (1) Centex Construction (1) City of Cappell TX ` . ..." (1) St Andres Management Services Lyndon J. C Andrews , P.E. Principal n ineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the a of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 01-LLWM01 - -F "e Key