Loading...
Freeport NIP(7.0)-LR030409 (2) gineers 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Report No.: 172472 Project No.: 037333 Date of Service: 03/10/2003 Report Date: 04/09/2003 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fi'esh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Hanson PLANT: 29 SPECIFICATION REQUIREMENTS STRENGTH: 3000 psi ~ 28 Days SLUMP On): 5" maximum AIR (%): TEST METHOD: 3% - 5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 MIX DESIGN I.D.: 9375 PLACEMENT DATE: 03/10/2003 WEATHER CONDITIONS: Overcast TIME SAMPLED: 2:50pm BATCH TIME: 2:20pm · TEMPERATURE (F) -AIR 58 F CONCRETE: 56 F TaUCK NO: 103 TICKET NO: 321227 AIR CONTENT (%): 4.0 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: Headwall, storm drain, Line 1, Station 0+00 SAMPLE LOCATION: Entire headwall REPORT OF TE,qTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 1 1 3.50 03/17/2003 7 125760 4450 Unbondcd Cap i 2 3.50 04/07/2003 28 161245 5700 Unbonded Cap 1 3 3.50 04/07/2003 28 160485 5680 Unbonded Cap Average 5690 1 4 3.50 05/05/2003 56 Unbonded Cap with Duke was notified. Report Distribution: (1) Duke Realty Services, LP (1) Paeheco Koch Consulting Engineers (1) Duke Realty Services, LP (1) Engineering Analyst J K. Scoq/Watson (1) City of Coppell Engineering Dept. (1) City of Coppell Engineering Dept. ,//.,MMT Operations Manager (1) Potter Concrete LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DK Page 1 of 1