Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
MacPlaza 1 Sun-LR 960906
"Excettence by Experience" CONSULTTNG ENG'rNEERS TN: Envi ronmenta[ Assessments Soils & Foundations Construction Materials Testing Commercial & [ndustria[ Inspection PO Box 92548 · South[ake, Texes 76092 · (817) 3~9-0281 FIELD COMPACTION REPORT PROJECT: Sunbelt Self Storage JOB #: 96-1672 DATE: 09-06-96 CLIENT: Sunbelt Selt Storage c/o Gra-Son Land, Inc LOCATION: Coppell DAY: Friday TIME: 10:00am CONTRACTOR: Kamont Construction TEST NO. LOCATION AND LIFT WATER DRY PER- PROCTOR CONT. DEN CENT NUMBER (%) (PCF) COMP Line A, 30" Storm Sewer: 1. @ Station 4+00 2. @ Station 3+00 3. @ Station 2+00 21%d Lift ] 18.9 104.9 96.5 21%G Lift I 19.7 107.1 98.5 2n(~ iLift ] 20.6 104.8 96.4 Ail tests passed. Minimum Compaction Required: Minimum of 4 tests per trip. 95% PROCTORS: i. Tn & Brn Silty Sandy Clay 2. Dk Brn Silty Sandy Clay 108.7 PCF @ 18.3% MOISTURE 99.2 PCF @ 23.7% MOISTURE Jeff Holden Technician