Riverview Office-CS030423 (2)T H E C 1 T Y O F
COPPELL
,,~
F -td'" ~ ~vrr'' 9
X A a ~ 8
Apri123, 2003
Tim Porter, P.E.
Dowdey, Anderson & Associates, Inc.
5225 Village Creek Drive, Suite 200
Plano, TX 75093
RE: Riverview Office Development
Lot 1, Block A
Construction Plan Review Comments
Dear Mr. Porter:
The City of Coppell has reviewed the referenced plans and has the following comments to offer:
General Notes -
1. A copy of the approved site plan should be included in the plan set.
2. Update all general notes to reflect current city standards and requirements.
Plat- ,t;.l:Q~ k1
Provide a~ drainage easement as shown on the Utility Plan/Profile.
Grading Plan -
It appears that that the runoff will go into Sandy Lake Road rather than into the inlet. The grades
may need to be modified to prevent this.
Drainage Area Map -
A section along the south side of the property may not be adequately sloped to allow for
drainage. Revisions may be necessary to prevent ponding in the residential area.
Utility Plan -
1. The owner has requested a 6" sanitary sewer line rather than the 8" line as shown. The city
has no objections to this request. lp ~
2. Move the sanitary sewer line to outside of the proposed ~1' drainage easement.
' ~>-I~~~-tl~te•samfary"sewe~-•-
4. Identify the possible utilities in the driveway onto Riverview Drive. Do these need to be
relocated?
5. Does the utility pole in the corner of the drive onto Riverview Drive need to be relocated? If
so, indicate.
255 PARKWAY * P.O.BOX 4]8 * COPPE LL TX ]5019 * TEL 9]2/462 0022 * FA% 9]2/304 36]3
Paving Plan -
1. All details in the construction plans that are included in our Standard Details should be
removed from the plans. The only details to be included in these plans are details that are
revised and specific to this project. The contractor is required to have a copy of the City of
Coppell Standard Details on the job site at all times during construction.
2. Are you proposing to use stamped concrete for the paver band in the driveway onto
Riverview Drive?
3. Verify the correct scale of the drawing.
4. Will ADA specifications be met across the driveway on Riverview Drive?
5. How do you propose to delineate the change in alignment across the drive onto Riverview
Drive?
SWPPP -
Provide a construction site notice in accordance with TCEQ General Permit Number TXR
150000.
Once the necessary corrections have been made, please return this marked-up set and two sets
of revised plans to the City for review. If you have any questions or need any additional
information, please contact this office at your convenience.
Sincerely,
~~Y`~-~-Y ~-~'
Teresa Turner, E.I.T.
Graduate Engineer
Office Phone: (972) 304-3681