Loading...
Freeport NIP(7.0)-LR030422RoneEn gineers 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: Duke Realty Services, LP Attn: Mr. JeffLangston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Report No.: 174741 Project No.: 037333 Date of Service: 04/11/2003 Report Date: 04/22/2003 Freeport l0 500 Freeport Parkway Coppell, TX Obtain samples of flesh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENCTm 4000 psi ~ 28 Days SLUMP (in): 3" - 5" AIR (%): TEST METHOD: NA ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 MIX DESIGN I.D.: 9349 PLACEMENT DATE: 04/11/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 3:45pm BATCHTIME: 3:28pm TEMPERATURE (F) - AIR 84 F CONCRETE: 79 TRUCK NO: 102 TICKET NO: 113602 AIR CONTENT (%): NA UNIT WEIGHT (pc0:' NA. OVERALL PLACEMENT LOCATION: Tie beam, Linc H between 4 and 5 SAMPLE LOCATION: Same as above REPORT OF TEgTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MARKED SLUMP SET NO. (inches) MAXIMUM DATE AGE LOAD TESTED (days) (lbs. force) COMPRESSIVE STRENGTH (psi) FRACTURE TYPE 1 1 3.75 1 2 3.75 1 3 3.75 1 4 3.75 Water added at site: Technician: Rick Smith Report Distribution: (I) Duke Realty Services, LP (1) Duke Realty Services, LP (1) City of Coppell Building Dept. (1) Potter Concrete 04/18/2003 7 103570 05/09/2003 28 05/09/2003 28 06/06/2003 56 20 gallons Started: 3:00pm Finished: 4:45pm (1) Pacheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Engineering Dept. 3660 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap ratson CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written appmvai of Rone Engineers, Ltd. 01DK Page 1 ofl gineers 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630~9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: Duke Realty Services, LP Attn: Mr. JeffLangston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Report No.: 174699 Project No.: 037333 Date of Service: 04/11/2003 Report Date: 04/22/2003 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: ~ On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi @ 28 Days SLUMP (in): 5" - 7" AIR (%): NA TEST METHOD: ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 MIX DESIGN I.D.: 9361 PLACEMENT DATE: 04/11/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: ll:20am BATCHTIME: 10:58am TEMPERATURE (17) - AIR 74 F CONCRETE: 71 F T~UCK NO: 102 TICKET NO: 113594 AIR CONTENT (%): NA UNIT WEIGHT (per):, NA- OVERALL PLACEMENT LOCATION: See pier inspection report #174698 SAMPLE LOCATION: Piers B-2.5 and A.3-2.5 REPORT OF TE,qT~ Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MARKED SLUMP DATE SET NO. (inches) TESTED MAXIMUM COMPRESSIVE AGE LOAD STRENGTH FRACTURE (days) (lbs. force) (psi) TYPE 1 1 6.25 1 2 6.25 I 3 6.25 1 4 6.25 See report ~174698 Technician: Rick Smith Report Distribution: (1) Duke Realty Services, LP (1) Duke Realty Se~wices, LP (1) City of Coppell Building Dept. (1) Potter Concrete 04/18/2003 7 05/09/2003 28 05/09/2003 28 06/06/2003 56 for technician time. Started: Finished: (1) Pacheco Koch Consulting Engineers (1) Engineering Analyst (I) City of Coppell Engineering Dept. 124150 4390 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap K. Scott Watson CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject maner provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DK Page 1 of 1 RoneEngineers 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 IN-PLACE DENSITY TESTING CHent: Project: Services: Duke Realty Services, LP Atto: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Freeport 10 500 Freeport Parkway Coppell, TX Perform In-Place Density Test in accordance with ASTM Standards. Report No.: 175013 Project No.: 037333 Date of Service: 04/16/2003 Report Date: 04/23/2003 PROJECT DATA CONTRACTOR: Duke Realty Sm-vices, LP Standard Counts Gauge: Troxler 3430 Test Methods: ASTM D-2922 Moisture Density ASTM D-3017 Gauge Serial No: 32720 Current: 667 Current: 3075 Test Mode: DT Previous: 655 Previous: 3081 MOISTURE DENSITY RELATIONS Maximum Project Requirements MJD No. Description Moisture % Density pcf Moisture Density 1 Tannish Brown Sandy Clay (Lime Treated) 22.0 100.0 Optimum + 95-100 min FIELD DENSITY TESTS TEST PROBE NO TESTLOCATION DEPTH M/D MOISTURE WET DENSITY DRY DENSITY DENSITY No. (%) (pcf) (pcl) (% max) Lime Subgrade 1 Building pad, 900' East by 100' North of 6" 1 22.7 118.0 96.2 96 southwest comer, final Lime Subgrade 2 Building pad, 900' East by 200' North of 6" 1 23.5 119.4 96.7 97 southwest comer, final Lime Subgrade 3 Building pad, 900' East by 300' North of 6" 1 24.2 118.6 95.5 96 southwest comer, f'mal Lime Subgrade 4 Building pad, 900' East by 400' North of 6" 1 22.3 116.4 95.2 95 southwest comer, final Lime Subgrade 5 Building pad, 900' East by 500' North of 6" 1 25.1 121.8 97.4 97 southwest comer, £mal LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, em.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 07DD Page 1 of 2