Loading...
Securelock-CS021126DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM. S -1204 Securlock Self Storage, zoning change request from LI and C (Light Industrial and Commercial) to LI/C -S -1204 (Light Industrial/Commercial, Special Use Permit - 1204), to allow the construction of a 49,380 square —foot mini- warehouse use, with a 1,900 square -foot caretakers quarter, and 5,520 square feet of office /warehouse, on 3.751 acres of property located at the northeast corner of S.H. 121 and Northpoint Drive, at the request of Andrew Smith, Houghton Capital Corporation. STAFF REP: Andrea Roy DRC DATE: November 26, 2002 and December S, 2002 CONTACT: Teresa M. Turner, E.I.T., Graduate Engineer (972)304 -3681 COMMENT STATUS: ✓PRELIMINARY REWS€B AT-MR P&Z- 1. All work along S.H. 121 Frontage Road will have to be approved and permitted by TxDOT (driveways, culverts, drainage, etc.) 2. More clearly define and label rights -of -way and property line limits o the site plan and civil drawings. 3. The domestic water and irrigation cannot be taken off of the fireline. The existing 8" waterline along the east side of this parcel is a public waterline. All water meters must be contained within the right -of -way or in easements. 4. A double detector check and vault is required where the fireline connects to the public waterline. These must be contained within easements. 5. Eliminate the 18" headwall and install a curb or grate inlet at the driveway to Northpoint Drive. 6. Eliminate the 30" headwall and tie into the 36" culvert at the driveway to S.H. 121 DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM. Securlock Self Storage Lot 1 Block A. Minor Plat to allow the construction of a 49,380 square —foot mini- warehouse use, with a 1,900 square -foot caretakers quarter, and 5,520 square feet of office /warehouse, on 3.751 acres of property located at the northeast corner of S.H. 121 and Northpoint Drive, at the request of Andrew Smith, Houghton Capital Corporation. STAFF REP: Andrea Roy DRC DATE: November 26, 2002 and December 5, 2002 CONTACT: Teresa M. Turner, E.I.T., Graduate Engineer (972)304 -3681 COMMENT STATUS: ✓PRELIMINARY 4b REVISED AFTER P&Z 1. Label the drainage easement in the comer of the property at the intersection of Northpoint Drive and S.H. 121 (Dimension, Vol., Page, etc.) 2. Show all required utility easements for water meters and vaults. 3. Include a comment on the plat that states: "Sidewalks will be constructed by the property owner when deemed necessary by the City Engineer." 4. Verify with TxDOT that no additional easements or rights -of -way are needed along the S.H. 121 Frontage Road.