Freeport NIP(7.0)-LR030507: RoneEngineers
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Client:
Project:
Services:
Duke Realty Services, LP
At~: Mr. JeffLangston
5495 BeR Line Road, Suite 360
Dallas TX 75254
Report No.: 175693
Project No.: 037333
Date of Service: 04/28/2003
Report Date: 05/07/2003
Freeport 10 ,
500 Freeport Parkway
Coppell, TX '
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
CONT~XCTOn: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT: On site
SPECIFICATION REQUIREMENTS
STRENGTH: 4000 psi (~ 28 Days
SLUMP (in): 6" maximum
AIR (%):
TEST METHOD:
NA
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
M~X DESIGN i.D.: 9349
PLACEMENT DATE: 04/28/2003
'WEATHER CONDITIONS: Clear
TIM~ SAMPLED: 4:10am BATCH T~M~: 3:45am
TEMPERATURE (F) - AIR 71 V CONCRETE: 81 F
THUC~C NO: 112 X~Cm~TNO: NA
Am CONT~,NT (%): NA trout W~.IGHT Cue0: NA
OVERALL PLACEMENT LOCATION:
Slab at grid lines N-X at 5-7
SAMPLE LOCATION: Line N.2 at 5.3
REPORT O1~ TE.~TS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
CYLINDER MEASURED MAXIMUM coMPRESSIVE
MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE
SET NO. (inches) TESTED (da~) Obs. force) (p~i) TYPE
1 1 4.50 05/05/2003 7 143190 5060 Unbonded Cap
1 2 4.50 05/26/2003 28 Unbonded Cap
1 3 4.50 05/26/2003 28 Unbonded Cap
1 4 4.50 06/23/2003 56 Unbonded Cap
Water added at site: 5 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no con~-ol. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be z~pmduoed except in full without the written approval of Rone Engineers, Ltd.
01DK Page I of 8
gineers
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Stp. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Client:
Services:
Duke Realty Services, LP
Attn: Mr. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 175693
Projeet No.: 037333
Date of Service: 04/28/2003
Report Date: 05/07/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
co~rP.~CTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
etAwr: On site
SPECIFICATION REQUIREMENTS
sxm~cTH: 4000 psi ~ 28 Days
SLtmP 0a): 6" maximum
AIR (%):
TEST METHOD:
NA
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138 SAMPLE LOCATION: LineP. 1 at6.8
ASTM C-39 REPORT 01~ TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
MIX DESIGN LD.: 9349
PLACEMENT DATE: 04/28/2003
WEATHER CONDITIONS: Clear
T1MESAMPLED: 5:10am BATCHTIME: 4:39am
TEMPERATURE (V)- Am 72 F CONCRETE: 83 F
TRUCK NO: 102 T~CK~T NO: 114239
Am cowrz~T (./.): NA UNIT WEIGHT (pcf): NA
OVERALL PLACEMENT LOCATION:
Slab at grid line~ N-X at 5-7
CYLINDER MEASURED
MARKED SLUMP DATE
SET NO. (inches) TESTED
2 1 5.00 05/05/2003 7
2 2 5.00 05/26/2003 28
2 3 5.00 05/26/2003 28
2 4 5.00 06/23/2003 56
Water added at site: 5 gallons
MAXIMUM COMPRESSIVE
AGE LOAD STRENGTH
(days) 0b~. force) (psi)
121965 4310
Unbonded Cap
Unbonded Cap
Unbond~d Cap
Unbonded Cap
LIMITATIONS: The te~t results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(cemposit/on, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clieats to whom they are add~ssed and shall not be reproduced except in full without the written approval of Ronc Engineers, L~.
01DK Page 2 of 8
RoneEng neers
8908 Ambassador Row, Dallns, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, St~. 150, Houston, TX 77040
Corporato Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
CHent:
Project:
Services:
Duke Realty Services, LP
Attn: Mr. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 175693
Project No.: 037333
Date of Service: 04/28/2003
Report Date: 05/07/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, east compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
co~-t~crom Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT: On site
SPECIFICATION REQUIREMENTS
STREI~GTIt: 4000 psi ~ 28 Days
SLUMP (in): 6" maximum
AIR (%):
TEST METHOD:
NA
ASTM C- 172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
MIX DESIGN I.D.: 9349
PLACEMENT DATE: 04/28/2003
WEATHER CONDITIONS: Clear
~ SAMPLED: 5:45am BATCH TIME: 5:26am
TEMPERATURE (F) - AIR 70 v CONCRETE: 81
TRUCK ~O: 113 TICI~T 1~O: 114249
AIR CO~rm~T (%): NA V~T w~1Girr (p~0:. NA
OVERALL PLACEMENT LOCATION:
Slab at grid linez N-X at $-7
SAMPLE LOCATION: Line Q.2 at 6.7
REPORT Oi~ TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
CYLINDER
MARKED
SET NO.
3
MEASURED MAXIMUM COMPRgSSIVE
SLUMP DATE AGE LOAD STRENGTH
(inches) TESTED (days) Obs. force) (psi)
4.75 05/05/2003 7 134200 4750
3 2 4.75
3 3 4.75
05/26/2003 28
05/26/2003 28
3 4 4.75
06/23/2003 56
Water added at site: 5 gallo~s
Unbonded Cap
Unbonded Cap ·
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prspared based upon the specific samples provided for t~8. We assume no rssponsibflity for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matte~ provided by persons or conditions over which we have no cenlrol. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01DK Page 3 of 8
8908 Ambassador Row, Dallas, TX 75247
2696 Grnvel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214)630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Client:
Project:
Services:
Duke Realty Services, LP
Attn: Mr. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 175693
Project No.: 037333
Date of Service: 04/28/2003
Report Date: 05/07/2003
Freeport 10
500 Freeport Parkway
Coppeli, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
co~P~Crom Duke Realty Services, LP
coNcRETE SUPPLIER: Potter
r~r: On site
SPECIFICATION REQUIREMENTS
STRENGTH: 4000 psi ~ 28 Days
SLt~fl' 0n): 6" maximum
AIR (%):
TEST METHOD:
NA
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
MIX DESIGN I.D.: 9349
PLACEMENT DATE: 04/28/2003
WEATHER CONDITIONS: Clear
TEVIgSAMPLED: 6:20am BATCItTIME: 6:10am
TEMeE~TVRE09-Am 68 F CONCP. ZTE: 83
TRUCKNO: 105 TI¢~T NO: 114259
AIR CONTENT (%): NA LrNIT WEIGHT (Pc0:
OVERALL PLACEMENT LOCATION:
Slab at grid lines N-X at 5-7
SAMPLE LOCATION: Line IL3 at 5.6
R~PORT OF TE~T~
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
CYLINDER MEASURED MAXIMUM COMPRESSIVE
blARK~D SLUMP DATE AGE LOAD STRENGTH
SET NO. (inches) TESTED (days) 0bs. force) (psi)
4 1 5.25 05/05/2003 '7 131270 4640-
4 2 5.25 05/26/2003 28
4 3 5.25 05/26/2003 28
4 4 5.25 06/23/2003 56
FRACfURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided fo~ testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01DK Page 4 of 8
ROneEng neers
8908Ambassador Row, Dnllas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
CHent:
Project:
Services:
Duke Realty Services, LP
Arm: Mr. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 175693
Project No.: 037333
Date of Service: 04/28/2003
Report Date: 05/07/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
coNTancToa: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
rt~r: On site
SPECIFICATION REQUIREMENTS
STRENGTH: 4000 psi ~ 28 Days
SLV~ On): 6" maximum
AIR (%):
TEST METHOD:
NA
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
MIX DESIGN I.D.: 9349
PLACEMENT DATE: 04/28/2003
WEATHER CONDmONS: Sunny
TIME SAMPLED: 7:05am BATCH rn~: 6:55am
TEMPE~TVRE(V)-Am 70 F CONC~TE: 83
T~VCKNO: 109 TIC~T NO: 114269
MR COUNT (%): NA trait w~IGgr ~0: NA
OVERALL PLACEMENT LOCATION:
Slab at grid linas N-X at 5-7
SAMPLE LOCATION: Line S.2 at 6.9
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
CYLINDER MEASURED MAXIMUM COMPRESSIVE
MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE
SET NO. (inches) TESTED (days) Obs. force) (psi) TYPE
5 1 4.50 05/05/2003 7 130010 4600 Unbonded Cap
5 2 4.50 05/26/2003 28 Unbonded Cap
5 3 4.50 05/26/2003 28 Unbonded Cap
5 4 4.50 06/23/2003 56 Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing We assume no responsibility for variation in quality
(compozition~ appearance, performance, etc.) or any other feature of similar subject mat~er provided by persons or cond/tions over which we have no control. Our le~ers and
reports are for the exclusive use oftha cl/ents to whom they are ad~ and shall not be reproduced except in full without the wfiP. en approval of Rone Engineers, La/.
01DK Page 5 of 8
ROneEngineers
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214)630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Client:
Project:
Services:
Duke Realty Services, LP
Atto: Mx. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 175693
Project No.: 037333
Date of Service: 04/28/2003
Report Date: 05/07/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fi'esh concrete at the placement locations, perform required field testing cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
CONTRACTOR: Di~ke Realty Services, LP
CONCRETE SUPPLIER: Potter
P~,~rr: - On site
SP~C~nCATION REQtaRE~m~rrs
s~NaTH: 4000 psi ~ 28 Days
SLUMP (in): 6" maxiroum
Am (%):
TEST blETHOD:
NA
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
MIXDESIGN I.D.: 9349
PLACEMENT DATE: 04/28/2003
WEATHER CONDITIONS: Cloudy
~ SAMPLED: 8:40am BATCH TII~: 8:24am
TEMPERATURE (F} - AIR 74 V CONC~TE: 83
TRUCK NO: 102 TICKET NO: 114279
Am coNTE~rr ¢%): NA trOT WE~G~rr (po0: NA
OVERALL PLACEMENT LOCATION:
Slab at g~id lines N-X at 5-7
SAMPLE LOCATION: Line T.4 at 6.7
REPORT OF TE~T~
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
CYLINDER MEASURED MAXI~ COMPRESSIVE
MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE
SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE
6 ! 5.00 05/05/2003 7 126050 4460 Unbonded Cap
6 2 5.00 05/26/2003 28 Unbonded Cap
6 3 5.00 05/26/2003 28 Unbonded Cap
6 4 ~ 5.00 06/23/2003 56 Unbonded Cap
LIMITATIONS: The test results presented he~'in were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be mprodueed except in full without the written approval of Rone Engineers, Ltd.
OIDK Page 6 of 8
gineers
8908 Ambassador Row, Dnllns, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothwny, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
CHent:
Services:
Duke Realty Services, LP
Arm: Mr. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 175693
Project No.: 037333
Date of Service: 04/28/2003
Report Date: 05/07/2003
Freepor~ 10
500 Freeport parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive stxength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
COZqXEACrOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
Pt~a~rr: On site
SPECIFICATION REQUIREMENTS
sxRENcTH: 4000 psi ~ 28 Days
SLUMP (in): 6" maximum
AIR (%):
TEST METHOD:
NA
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
M~X OESm~ [~.: 9349
P~C~SmnT DAT~-: 04/28/2003
~AT~R CO~ONS: Cloudy
x~ s~o: 9:35~ ~AXC~ ~: 9:20~
~Pe~X~-~ 75 ~ CO~: 82
~VC~ ~O: 112 ~C~X nO: 114289
~ co~ (%): NA omx ~[G~ ~0: NA
O~L P~NT ~CA~ON:
S~ at ~d ~n~ N-X at 5-7
SAMPLE LOCATION: Line U.2 at 6.6
REPORT OF TE~T~
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
CYLINDER MEASURED MAXIMUM COMPRESSIVE
MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE
SET NO. (inches) TESTED (days) (lbs. force) (ps0 TYPE
7 1 4.75 05/05/2003 7 132040 4670 Unbonded Cap
7 2 4.75 05/26/2003 28 Unboaded Cap
7 3 4.75 05/26/2003 28 Unbonded Cap
7 4 4.75 06/23/2003 56 Unbonded Cap
LIMITATIONS: The test results presented hemln were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without ~e written approval of Rone Englneera, Ltd.
01DK Page 7 of 8
ROneEng neers
8908 Amba~ador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Client:
Project:
Services:
Duke Realty Services, LP
Attn: Mr. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 175693
Project No.: 037333
Date of Service: 04/28/2003
Report Date: 05/07/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placemant locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
CONT~CTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PI,Ar~T: On site
SPV. CmCATION ~ZQt~Z~Z~TS
S~IE~CTH: 4000 psi ~ 28 Days
SLUMP (la): 6" maximum
AIR (%):
TEST METHOD:
NA
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
MIX DESIGN I.D.: 9349
PLACEMENT DATE: 04/28/2003
WEATHER CONDITIONS: Cloudy
TIMESAM~LED: 10:45am BATCHTIME: 10:23am
T~MPERATUI~ ('F) - AIR 75 F CONCaZ~: 84
TRVCK r~o: 102 TICm~T SO: 114299
AIR CONTENT (%): ~TA UNIT WEIGHT (pel): NA
OVERALL PLACEMENT LOCATION:
Slab at grid lines N-X at 5-7
SAMPLE LOCATION: Line V.3 at 5.2
REPORT Ol~ TE,qTR
Concrete Comp~ssive Cylinder 6" x 12" (area 28.27 sq. in.)
CYLINDER MEASURED
MARKED SLUM])
SET NO. (inches)
8 1 4.75
MAXIM~o~I
DATE AGE LOAD
TESTED (days) (lbs. force)
05/05/2003 7 136010
COM?RESSIV~
STRENGTH FRACTURE
(~a) t3,a,E
4810 Unbonded Cap
8 2 4.75
8 3 4.75
05/26/2003 28
05/26/2003 28
Unbonded Cap
Unbonded Cap
8 4 4.75 06/23/2003
Water added at site: 5 gallons
56
Technician: Jeremy Watts
Report Distribution:
(1) Duke Realty Services, LP
(I) Duke Realty Service~, LP
(1) City of Coppell Building Dept.
(1) Potter Concrete
Started: 3:15am Finished: 12:30pm
(1) Pachcco Koch Consulting Englneam
(I) Engineering Analyst
(1) City of Coppell Engineering Dept.
Unbonded Cap
K. Scott Watson
CMT Operations Manager
LIMITATIONS: The test results presemed herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
~ports are for the exclusive use of the clieats to whom they are addressed and shall not be reproduced except in full without the writtea approval of Rone Engineers, Ltd.
01DK Page 8 of 8
RoneEngineerS
8908 Ambassador Row, DaHan, TX 75247
2696 Gravel DHve, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Client:
Project:
Services:
Duke Realty Services, LP
Attn: Mr. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 174418
Project No.: 037333
Date of Service: 04/08/2003
Report Date: 05/07/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain ~mples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
CONTRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT: 011 site
SPECIFICATION REQUIi~EMENTS
STRENGTH: 4000 psi ~ 28 Days
SLVl~ (in): 5" - 7"
AIR (%):
TEST METHOD:
NA
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
MIXDESIGN I.D.: 9361
PLACEMENT DATE: 04/08/2003
WEATHER CONDITIONS: Sunay
TIM~ SAMPLED: 10:09am BATCH TIME: NA
TEMPERATURE (I~-AIR 57 F CONCRETE: 61 v
TRUCK NO: NA TICKET No: NA
~aR CONTZNT (%): NA t~T WEIGHT (pc0: NA
OVERALL PLACEMENT LOCATION:
See report #174417
SAMPLE LOCATION:
REPORT OF TEgTS
Column lines A-6.5, A-6, A-5.5
and A-5
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
CYLINDER MEASURED
MARKED SLUM?
SET NO. (inches)
DATE
TESTED
MAXIMUM COMPRESSIVE
AGE LOAD STRENGTH FRACTURE
(days) (lbs. force) (psi) TYPE
1 1 6~25
! 2 6.25
1 3 6.25
04/15/2003 7 136495
05/06/2003 28 158300
05/06/2003 28 148335
Average
4830 Unbonded Cap
5600 Unbonded Cap
5250 Unbonded Cap
5430
1 4 6.25 06/03/2003
See report #174417 for technician time.
56
Technician: Rick Smith
Report Distribution:
(1) Duke Realty Services, LP
(1) Duke Realty Services, LP
(1) City of Coppell Building Dept.
(1) ?otter Concrete
Stmea:
Finished:
(1) Pacheco Koch Consulting Engineers
(1) Engineering Analyst
(1) City of Coppell Engineering Dept.
Unbonded Cap
CMT Operations Manager
LIMITATIONS: The test results presonted heldn were prepared based upon the specific samplespmvided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addrezsed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01DK Page 1 of 1
RoneEngineers
Client:
Duke Realty Services, LP
Attn: Mr. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project:
Services:
8908 Ambassador Row, Dallas, TX 75247
2696 Gravd Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Report No.: 175690
Project No.: 037333
Date of Service: 04/28/2003
Report Date: 05/07/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform requi~d field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
CONTRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter Concrete
PLANT: On site
SPECmCATION REQtrr~t~mNTS
s~NaTH: 4000 psi ~ 28 Days
SLUMP (in): 5" - 7"
AIR (%):
TEST METHOD:
NA
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
MIX DESIGN I.D.: 9361
PLACESmNT CATE: 04/28/2003
WEATHER CONDITIONS: Cloudy
TIME SAMPLED: 2:21pm RATC~ TtSm: 2:05pm
TEMPERATURE (F') - AIR 79 V CONCRETE: 81 v
MUCKNO: 114 ~C~TNO: 114315
AIR CONTENT (%): NA uwr WEIGHT (pc0: NA
OVERALL PLACEMENT LOCATION:
Please refer to report #175689 for colunm lines to all the piers drilled today
SAMPLE LOCATION: Lines W-8, X-8 and Y-8
REPORT Ol~ TE,~T,~
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
CYLINDER MEASURED
MARKED SLUMP
SET NO. (inches)
1 1 5.25
1 2 5.25
1 3 5.25
1 4 5.25
See report #175689 for
Technician: Rick Smith
Report Distribution:
(1) Duke Realty Services, LP
(1) ~ Realty Services, LP
(I) City of Coppdl Building Dept.
(1) Potter Concrete
DATE AGE
TESTED (days)
05/05/2003 7
05/26/2003 28
05/26/2003 28
06/23/2003 56
technician time.
Started:
Finished:
(I) Pacheeo Koch Consulting Engineers
(1) Engineering Analyst
(1) City of Coppdl Ensinccring Dept.
MAXIMUM COMERESSIVE
LOAD STRENGTH FRACTURE
Obs. force) (psi) TYPE
111290
3940 Unbonded Cap
UnbondedCap
Unbonded.Cap
Unbonded Cap
K. Scott Watson
CMT Operations Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subjent matter provided by persons or conditions over which we have no eentrol. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in filll without the written approval of Rone Engineers, Ltd.
01DK Page 1 of 1
RoneEn iheers
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste, 150, Houston, TX 77040
Corporate Phone: (214) 630=9745
CONCRETE BEAM FLEXURAL STRENGTH
Client:
Project:
Services:
Duke Realty Services, LP
Attn: Mr. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No,: 175694
Project No.: 037333
Date of Service: 04/28/2003
Report Date: 05/07/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, pert'oma required field testing, cast flexural strength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
CONTRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT: OH site
SPECIFICATION RRQUIREMENTS
STRENGTH: 650 psi ~ 28 Days
SLUMP (in): 6" maximum
Am (%): NA
TEST METHOD: ASTM C-172
ASTM C-143
ASTIVl C-1064
ASTM C-78
PROJECT DATA
MIX DESIGN I.D.: 9349
PLACEMENT DATE: 04/28/2003
WEATHER CONDITIONS: Clear
TIME SAM~PLED: 4:10am BATCHTIME: 3:45am
TEMPERATURE (F)- AIR 75 P CONCRETE: 8 ! F
TRUCK NO: 112 TICKET NO: NA
~a~ coNTeNT (%): NA tr~X wE]Gar (pc0: NA
PLACEMENT LOCATION: Slab at grid lines N-X at 5-7
ASTM C-31
ASTM C-231
SAMPLE LOCATION:
ASTM C-138
REPORT OF TESTS
Line N.2 at 5.3
Concrete Flexural Strength 6" x 6" Beams Span Length 18"
BEAM MEASURED MAXIMUM MODULUS OF AVG AVG
MARKED SLUMP DATE AGE LOAD RUPTURE VgIDTH DEPTH
SET NO. (inches) TESTED (days) (lb~. force) ~si) (in) On)
1 1 4.50 05/05/2003 7 7560 630 6.06 5.97
1 2 4.50 05/26/2003 28
1 3 4.50 05/26/2003 28
Water added at site: 5 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by pc~sons or conditions over which we have no con~'ol. Our letters and
repons are for the ettclusive use of the clients to whom they are addressed and shall not be reproduced except in full without thc written approval of Rone Engineers, Ltd.
02DK page 1 of 4
RoneEn g
8908 Ambassador Row, Dallas, TX 75247
2696 Grnvel Drive, Fort Worth, TX 76118
6300 Rethway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE BEAM FLEXURAL STRENGTH
Client:
ProJect:
Services:
Duke Realty Services, LP
Attn: Mr. Seffl_~ngston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 175694
Project No.: 037333
Date of Service: 04/28/2003
Report Date: 05/07/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast flexural st~ngth samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
COmmACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT: On site
SPECIFICATION REQUIREMENTS
STRENGTH: 650 psi ~ 28 Days
SLUMP (in): 6" maximum
~m (%): NA
TEST METHOD: ASTM C-172
ASTM C-143
ASTM C-I064
ASTM C-78
PROJECT DATA
MIX DESIGN I.D.: 9349
pt, AcEMENT DATE: 04/28/2003
WEATI-IER CONDITIONS: Clear
TIME SAMPLED: 5:45am BATCH ~: 5:26am
TEMPERATURE (F) - AIR 70 F CONCRETE: 81 P
TRUCKNO: 113 TICS~T NO: 114249
AIR CONTENT (%): NA t~OT WEIGHT (PC0: NA
PLACEMENT LOCATION: Slab at grid lines N-X at 5-7
ASTM C-31
ASTM C-231
SAMPLE LOCATION:
ASTM C-138
REPORT OF TESTS
Line Q.2 at 6.7
Concrete Flexural Strength 6" x 6" Beams Span Length i 8"
BEAM MEASURED MAXXMUM MODULUS OF AVG AVG
MARKED SLUMP DATE AGE LOAD RUPTURE WIDTH DEPTH
SET NO. (inches) TESTED (days) Obs. force) (psi) (in) (in)
2 1 4.75 05/05/2003 7 7080 610 6.02 5.89
2 2 4.75 05/26/2003 28
2 3 4.75 05/26/2003 28
Beam specimen's moisture condition was wet at the time of testing, all specimens
were ground as needed and tested with the use of leather shims.
Water added at site: 5 gallons
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by pemons or conditions over which we have no conuol. Om' letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
02DK Page 2 of 4
RoneEngineers
8908 Ambassador Row, Dallas, TX 75:247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 7?040
Corporate Phone: (214) 630=9745
CONCRETE BEAM FLEXURAL STRENGTH
Client:
Project:
Services:
Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 175694
Project No.: 037333
Date of Service: 04/28/2003
Report Date: 05/07/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the plaeemem locations, perform required field testing, cast flexural sU'ength samples and bring samples
back to the laboratory for curing and testing in accordance with applicable standards.
CONTRACTOR: Duke Realty Services, LP
concRETE suPrnlra: Potter
PL~NT: On site
SPECIFICATION REQUIREMENTS
ST~NGXH: 650.psi ~ 28 Days
SLUMP On):
AIR (%):
TEST Wi~THOD:
ASTM C- 172
ASTM C-143
ASTM C-1064
ASTM C-78
PROJECT DATA
MIX DESIGn I.D.: 9349
PLACEMENT DATE: 04/28/2003
WEATHER CONDITIONS: Sunny
TIME SAbIPLED: 7:05am BATCHTIME: 6:55am
TEMPERATURE (F) - AIR 70 F CONCRETE: 83 F
xnucI~ no: 109 TIC.EX nO: 114269
Am coNTzNT (%): NA UnIT W~iGrrr ~f): NA
PLACEMENT LOCATION: Slab at grid lines N-X ut 5-7
ASTM C-31
ASTIVl C-231
SAMPLE LOCATION:
ASTM C-138
REPORT OF TESTS
Line S.2 at 6.9
Concrete Flexu.ml Sh'ength 6" x 6" Beams Span I.,ength 18"
BEAlVI
MARKED
SET NO.
MEASURED MAXIMUM MODULUS OF AVG AVG
SLUMP DATE AGE LOAD RUPTURE WIDTH DEPTH
(inches) TESTED (days) Obs. forx:e) (psi) (in) 0n)
3 ! 4.50 05/05/2003. 7 7220 605 6.09 5.94
3 2 4.50 05/26/2003 28
3 3 4.50 05/26/2003 28
Beam specimen's moisture condition was wet at the time of testing, all specimens
were ground as needed and tested with the use of leather shims.
LIMITATIONS: Thc test results pmsen~l herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter pwvided by persons or conditions over which we have no con,roi. Our letters and
reports are for the exclusive use of the clients to whom they arc addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
02DK Page 3 of 4
RoneE g
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE BEAM FLEXURAL STRENGTH
Client:
Project:
Services:
Duke Realty Services, LP
Atto: Mr. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 175694
Project No.: 037333
Date of Service: 04/28/2003
Report Date: 05/07/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast flexural strength samples and bring samples
back to the laborato~ for curing and testing in accordance with applicable standards.
CONTaACrOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLA~r: On site
SPECIFICATION REQUIREMENTS
ST~NGTH: 650 psi ~ 28 Days
SLUMP (in): 6" maxi~unl
Am (%): NA
TEST METHOD: ASTM C-172
ASTM C-143
ASTM C- 1064
ASTM C-78
PROJECT DATA
MOCOES~G~ no.: 9349
PLACEMENT rATE: 04/28/2003
WEATHER CONDITIONS: Cloudy
TIME SAMPLED: 9:35am BATCH Tram: 9:20am
TEMPEKATURE(I~-AIR 75 F CONCRETE: 82 P
T~UC~C NO: 112 TIC~T NO: 114289
AIR CONTENT (%): NA t~T WEtam' (pc0: NA
PLACEMENT LOCATION: Slab at gr/d lines N-X at 5-7
ASTM C-31
ASTM C-231
SAMPLE LOCATION:
ASTM C-138
REPORT OF TESTS
Line U.2 at 6.6
Concrete Flexural S~'ength 6" x 6" Beams Span Length 18"
BEAM
MARKED
SET NO.
MEASURED MAXIMUM MODULUS OF AVG
SLUMP DATE AGE LOAD RUPTURE WIDTH
(inches) TESTED (days) Obs. force) (psi) (in)
AVG
DEPTH
4 1 4.75 05/05/2003 7 7570 620 6.05
6.03
4 2 4.75 05/26/2003 28
4 3 4.75 05/26/2003 28
Beam specimen's moisture condition was wet at the time of testing, all specimens .
were ground as needed and tested with the use of leather shims.
Please see report #175693 for technician time
Technician: Jeremy Watts
Report Distribution:
(1) Duke Realty Services, LP
(I) Duke Realty Services, LP
(1) City of Coppell Building Depc
(1) Porter Conc~te
Started: Finished:
(1) Pacbeco Koch Consulting Engineers
(1) Engineering Analyst
(1) City 0f Coppell Engineering Dept.
K. Scott Watson
CMT Operations Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We sssum¢ no responsibility for variation in quality
(cOmposition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addres,sed and shall not be reproduced except in full without the written approval of Rone Engine. s, Ltd,
02DK Page 4 of 4
: RoneEngineers
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fart Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Client:
Project:
Services:
Duke Realty Services, LP
Am: Mr. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 175778
Project No.: 037333
Date of Service: 04/29/2003
Report Date: 05/07/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
coNTRAcrom Duke Realty Services, LP
CONCRETE SUPPLIER: Potter Concrete
PlOdS: On site
SPEC~nCATION REQVmV~M~NTS
STRENGTH: 4000 psi ~ 28 Days
sLlnvm (in): 5" - 7"
Am (%):
TEST METHOD:
NA
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
MIX D~.SlGN LO.: 9361
PLACEMENT DATE: 04/29/2003
WEATHER CONDITIONS: So. nlly
TIMESAMPLEO: l:31pm RATC~X~m: l:09pm
TEMPERATURE (F) - AIR 81 F CONCRETE: 85 F
~VCK NO: 116 TICE~T NO: 114385
Am cowrENT (%): NA trait WEIGHT (PC0:. NA
OVERALL PLACEMENT LOCATION:
Please refer to re'port #175777 ~r column lines to all the piers drilled today
SAMPLE LOCATION: Lines BB-3, CC-3 and DD~3
REPORT OF TE,qT~
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
CYLINDER MEASURED MAXIMUiVI
MARKI~D SLUMP ~ DATE AGE LOAD
SET NO. (inches) TESTED (days) Obs. force)
COMPRESSIVE
STRENGTH FRAui URE
(psi) TYPE
1 ! 5.50 05/06/2003 7
1 2 5.50 05/27/2003 28
1 3 5.50 05/27/2003 28
1 4 5.50 06/24/2003 56
See Report #175777 for technician time
Technklan: Rick Smith
Report Distribution:
(1) Duke Realty Services, LP
(1) Dukc Realty Services, LP
(1) City of Coppell Building Dept.
(1) Potter Con~te
Ftniahed:
(1) Pachcco Koch Con,~lting Engineers
(1) Engineering Analyst
(1) City of Coppell Engine~dng l)~t.
111505
3940 Unbonded Cap
Unbonded Cap
Unbonded Cap
Unbonded Cap
K. Scott Watson
CMT Operations Manager
LIMITATIONS: The test results presented herein were pmparod based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no con~'ol. Our letters and
re'ports are for thc exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
O1DK Page 1 of I
ROneEn:gineerS
Client:
Duke Realty Services, LP
At'm: Mr. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project:
Services:
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rethway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Report No.: 175786
Project No.: 037333
Date of Service: 04/29/2003
Report Date: 05/07/2003
Freepor~ I 0
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, ca~t compressive s~rength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
co~rancroR: Duke Realty Services, LP
CONCR~TR SUPPLIER: Potter
PLA~T: On site
SPECIFICATION REQUIREMENTS
STRENG~: 4000 psi ~ 28 Days
SLUMP (In): 3" - 5"
AIR (%):
TEST METHOD:
3% - 5%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C- 1064
ASTM C-138
ASTM C-39
PROJECT DATA
MIX DESIGN I.D.: 7752 '~
PLACEMENT DATE: 04/29/2003
WEATIIER CONDITIONS: Clear
TIME SAMPLED: 4:10am BATCHTIME: 3:54am
TEMPERATURE (F) - AIR 74 V CONCRETE: 83 v
~VCK NO: 106 aac~? NO: 114319
Am ¢o~rrEl~r (%): 7.0 ~ WmGrrr (vet): NA
OVERALL PLACEMENT LOCATION:
Paving - entryway, parking area south of building at southwest comer (0-90' north - i5' west
to 369' east) of south parking ares
SAMPLE LOCATION: 3' west x 10' north of southeast
REPORT OF TE~gT,g comer of parking area
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
CYLINDER bIEASURED MAXIMUM COMPRESSIVE
MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE
SET NO. (inches) TESTED (days) Obs. force) (psi) TYPE
1 1 4.75 05/06/2003 7 97820 3460 Unbonded Cap
1 2 4.75 05/27/2003 28 Unbonded Cap
1 3 4.75 05/27/2003 28 Unbonded Cap
1 4 4.75 06/24/2003 56
Water added at site: 5 gallons
Contractor notified of high air content.
UnbondedCap
LIMITATIONS:.. Thc test rashes presented herein were prepared based, upon. thc. specific samples, provided for testing. We assume no responsibility f~r variation in quality
(composmon, appearance, performance, etc.) or any other fimture of slrmlar subject matter provided by persons or conditions over which we have no conuul. Our letters and
reports are for thc exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
O1DK Page 1 of 6
gineers
8908 Ambassador Row, Dallas, TX 75247
2696 Grovel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
C~ient:
Project:
Services:
Duke Realty Services, LP
At~: Mr. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 175786
Project No.: 037333
Date of Service: 04/29/2003
Report Date: 05/07/2003
Freeport I 0
500 Freeport Parkway
Coppell, TX
Obtain samples of flesh concrete at the placement locations, perform required field testing, cast compressive sU~ngth samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
conxRAcrom Duke Realty Services, LP
CONCRETE SUPPLIER: Pottor
P~mT: On site
SPECIPICATION REQUIREMENTS
STRENGTH: 4000 psi ~ 28 Days
SLUMP (in): 3" - 5"
AIR (%):
TEST METHOD:
3% - 5%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
MIX DESIGN I.D.: 7752
P~.~C~M~NT DATE: 04/29/2003
WEATHER CONDITIONS: Clear
TIME SAMPLED: 5:10am BATCH TIME: 4:58ai11
TEMPERATURE CF) - AIR 72 F CONCRETE: 83 P
TRUCKNO: 107 TICKET NO: 114328
AIR CO~T~Wr (%): 6.4 C~IT WEIGHT (pc0:' NA
OVERALL PLACEMENT LOCATION:
Paving - entryway, parldng area south ofbuildlng at southwest comer (0-90' north - 15' west
to 369' east) of south parking area
SAMPLE LOCATION: 35' west x 25' south of northeast
REPORT Ol~ TE~TR comer of paving
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
CYLINDER MEASURED MAXIMUM
MARKED SLUMP DATE AGE LOAD
SET NO. 0nches) TESTED (days) Obs. force)
2 1 4.50 05/06/2003 7
2 2 4.50 05/27/2003 28
2 3 4.50 05/27/2003 28
2 4 4.50 06/24~003
Water added at site: 10 gallons
Contractor notified of high air content.
COMPRESSIVE
STRENGTH FRACTURE
(psi) TYPE
106875 3780 Unbonded Cap
UnbondedCap
Unbonded Cap
56 Unbonded Cap
LIMITATIONS: The test results presented herein were p~pared based upon thc specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, eto;) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
~por~ are for the exclusive usc of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Ronc Engineers, Ltd.
01DK Page 2 of 6
:RoneEngineers
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
CHent:
ProJect:
Services:
Duke Realty Services, LP
Attn: Mr. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 175786
Project No.: 037333
Date of Service: 04/29/2003
Report Date: 05/07/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fi'esh concrete at the placement locations, perform required field testing, east compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
CONTRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
P~T: On site
SPEClV~CATION REQtnREsmNTS
STRENGTH: 4000 psi ~ 28 Days
SLUIHP (In): 3" - 5"
AIR (%):
TEST METHOD:
3% - 5%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
PROJECT DATA
MIX DESIGN LD.: 7752
PLACEMENT DATE: 04/29/2003
WEATHER CONDITIONS: Partly cloudy
TIME SAMPLED: 6:15am BATCHTLME: 6:04am
Ti~,MPERATURI~(F)-AIR 71 F co~cRETE: 83 F
TRUCKNO: 106 T~C~T NO: 114338
AIR CONTENT (%): 6.5 UNIT WEtGtrr (pc0: NA
OVERALL PLACEMENT LOCATION:
Paving - emryway, parking area south of building at southwest comer (0-90' north - 15' west
to 369' esso of soudi parking area
SAMPLE LOCATION: 105' west x 7' north of southeast
RF, PORT OF TERT~ comerofpaving
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
CYLINDER MEASURED MAXIMUM COMPRESSIVE
MARI~D SLUMP DAT~ AGE LOAD STRENGTH FRACTUR~
SET NO. (Inches) TESTED (days) Obs. force) (psi) TYPE
3 1 5.00 05/06/2003 7 96600 3420 Unbonded Cap
3 2 5.00 05/27/2003 28 Unbonded Cap
3 3 5.00 05/27/2003 28 Unbonded Cap
3 4 5.00 06/24/2003 56 Unbonded Cap
Water added at site: 10 gallons
Contractor notified of high air content.
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appenrance, performance, etc.) or any other feature of similar subject mar're' provided by persons or conditions over which we have no control. Our lcllers and
reports are for the exclusive usc of the clients to whom they are addressed and shall not be reproduced except in full without the w~tten approval of Ronc Engineers, L~.
01DK Page 3 of 6
gineers.
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Client:
Project:
Services:
Duke Realty Services, LP
Attn: Mr. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 175786
Project No.: 037333
Date of Service:~ 04/29/2003
Report Date: 05/07/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
CO~CrOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PCnNT: On site
SPEC~mcATIOr~ HEQVIR~MENTS
STRENGTH: 4000 psi ~ 28 Days
SLU/~ (in): 3" - 5"
AlE (%):
TEST METHOD:
3% - 5%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
M~X DES~aN LD.: 7752
PLACEMENT DATE: 04/29/2003
WEATHER CONDITIONS: Cloudy
TIME SAMPLED: 7:30am BATCH TIME: 7:14am
TEMPERATURE O~)- Am 72 F CONCRETE: 82 v
TRUCK NO: 107 TICKET NO: 114348
AIR CONTENT (%): 5.6 t~uT V~IGHT (pc~): NA
OVERALL PLACEMENT LOCATION:
Paving - en~nvey, paring a~a south of buildlng at southwest corner (0-90' north - 15' west
to 369' east) of senth parking area
SAMPLE LOCATION: 125' west x 20' south of northeast
REPORT Ol~ TESTS comer of paving
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
CYLINDER
MARKED
SET NO.
4 1
4 2
4 3
4 4
MEASURED MAXIMUM COMPRESSiVE
SLUMP DATE AGE LOAD STRENGTH FRACTURE
(inches) TESTED (days) Obs. force) (psi) TYPE
4.75 05/06/2003 7 107715 3810 Unbonded Cap
4.75 05/27/2003 28 Unboaded Cap
4.75 05/27/2003 28 Unbonded Cap
4.75 06/24/2003 56 Unboaded Cap
LIMITATIONS: The test results presented herein werepreparcd based upon thc specific samplesprovidcd for teetlng. We assume no responsibility fur variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
repons are for the exclusive use of thc chents to whom they are addressed and shall not be reproduced except in full without thc written approval of Reno Engineers, Ltd.
01DK Page 4 of 6
R°neEngineers
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, St~ 150, Homt~n, TX 77040
Corporate Phone: (214} 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Client:
Project:
Services:
Duke Realty Services, LP
ARm Mr. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 175786
Project No.: 037333
Date of Service: 04/29/2003
Report Date: 05/07/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
COnTHACrOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PL~rr: On site
SPECIFICATION REQUIREMENTS
STRENGTH: 4000 psi ~ 28 Days
SL~IP (i.): 3" - 5"
~dR (%):
TEST METHOD:
3% - 5%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
ASTM C-39
~nx DESIGN I3.: 7752
PLACEMENT DATE: 04/29/2003
WEATHER CONDITIONS: Cloudy
TIME SAMPLED: 8:35am BATCHTIME: 8:23~
TEMPE~ ~ - ~ 75 F CON~TE: 83 F
~u~ ~o: 106 ~C~T ~O: 114358
~ ~ (%): 5.2 ~T ~a~ ~0: NA
O~L PLA~ LOCA~ON:
Pa~ng - ~y, p~ng ~ mu~ of building at ~u~w~t comer (~90' no~ - 15' w~t
to 369' ~) of sou~ paring ~
SAMPLE LOCATION: 90' east x 30' south of northwest
REPORT 01~ TESTS comer of paving
Concrete Compressive Cylinder 6" x 12, (area 28.27 sq. in.)
CYLINDER MEASURED
MARKED SLUMP
SET NO. Ouches)
5 1 4.50
MAXIMUM COMPRESSIVE
DATE AGE LOAD STRENGTH
TESTED (days) (lbs. force) (psi)
05/06/2003 7 107915 3820
5 2 4.50
5 3 4.50
05/27/2003 28
05/27/2003 28
5 4 4.50
06/24/2003 56
Water added at site: 5 gallons
Unbonded Cap
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for ~esting. We assume no respo~ibility for variation in quality
(compos/tion, appearance, performance, etc.) or any other ~ature of sim/lar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01DK Page $ of 6
RoneEn
ineer$
8908 Ambassador Row, Dallas, TX 7S247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214)630=9745
CONCRETE COMPRESSIVE STRENGTH TEST
CHent:
Project:
Services:
Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 175786
Project No.: 037333
Date of Service: 04/29/2003
Report Date: 05/07/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laborato~ for curing and testing in accordance with applicable standards.
PROJECT DATA
commACrOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PL~qr: On site
SPECIFICATION REQUIReMeNTS
ST~Na'rm 4000 psi ~ 28 Days
SLUMP On): 3" - 5"
AIR (%):
TEST METHOD:
3% - 5%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
MIX DESIGN I.D.: 7752
PLACEMENT DARE: 04/29/2003
WEATHER CONDITIONS: Partly cloudy
TIME SAMPLED: 9:45am BATCH X~4~: 9:33am
TEMPERATURE (F) - AIR 75 F CONCRETE: 83 v
TRVCKNO: 107 TICI~T NO: 114369
Am CONTENT (%): 4.7 trmT WEIGHT (pc0: NA
OVERALL PLACEMENT LOCATION:
Paving - enh'yway, parking area south of building at southwest comer (0-90' north - 15' west
to 369' east) of south parking area
SAMPLE LOCATION: 45' east x 10' south of northwest
comer of paving
ASTM C-39 REPORT Ol7 TERT~
Concrete Compressive Cylinder 6" x 12" (arca 28.27 sq. in.)
CYLINDER
MARKED
SET NO'
MEASURED MAXIMUM
SLUMP DATEE AGE LOAD
(inches) TESTED (days) Obs. force)
6 1
4.75 05/06/2003 7 109235
COMPRESSIVE
STRENGTH FRACTUR~
(psi) TYPE
3860 Unbonded Cap
4.75 05/27/2003 28
4.75 05/27/2003 28
6 4
4.75 06/24/2003 56
Water added at site: 5 gallons
Te~hnieinn: Jeremy Watts
Report Distribution:
(1) Duke Realty Services, LP
(1) Duke Reelty Services, LP
(I) City of Coppell Building Dept.
(1) Po~er Concrete
Started: 3:15am Finished: 12:45pm
(1) Paehaco Koch Consulting Engineer~
(I) ~ngineering A~yst
(1) City of Coppell Engineering Dept.
Unbonded Cap
Unbonded Cap
IC Scott Watson
CMT Operations Manager
LIMITATIONS: The te~ results presented herein were prepared based upon the specific samples pwvided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject maim' provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addr~sed and shall not be reproduced except in full without the writlen appmval of Rone Engineers, Ltd.
01DK Pnge 6 of 6
ugineers
Client:
Project:
Services:
Duke Realty Services, LP
Attn: Mr. JeffLangston
5495 BeR Line Road, Suite 360
Dallas TX 75254
Freeport 10
500 Freeport Parkway
Coppell, TX
Perform In-Place Density Test in accordance with ASTM Standards.
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
IN-PLACE DENSITY TESTING
Report No.: 176094
Project No.: 037333
Date of Service: 05/02/2003
Report Date: 05/07/2003
PROJECT DATA
CONTRACTOR: Duke Realty Services, LP
Test Methods: ASTM D-2922
ASTM D-3017
Gouge: Troxler 3430
Gauge Serial No: 32720
Test Mode: DT
bl/DNo. Description
Moisture
Current: 653
Prevtous: 661
MOISTURE DENSITY RELATIONS
Maximum
Moisture % Density pcf
1 Tannish Brown Sandy Clay (Lime Treated) 22.0 100.0
Standard Counts
Density
Current: 3078
Previous: 3087
Project Requirements
Moisture Density
Optimum + 95-100
FIELD DENSITY TESTS
TEST PROBE
NO TEST LOCATION DEPTH
M/D MOISTURE WET DENSITY DRY DENSITY DENSITY
No. (%) Coco (Pc0 (% max)
Lime Subgrade
1 Building pad, 1500' east by 100' north of 6" 1 22.3 116.8 95.5 96
southwest comer, final
Lime Subgrade
2 Building pad, 1500' east by 200' north of 6" 1 22.9 119.1 96.9 97
southwest comer, fatal
Lime Subgrade
3 Building pad, 1500' cast by 300' north of 6" 1 23.4 117.4 95.1 '95
southwest comer, final
Lime Subgrade
4 Building pad, 1500' east by 400' north of 6" 1 23.5 I 19.2 96.5 97
southwest comer, final
Lime Subgrade
5 Building pad, 1500' east by 500' north of 6" 1 24.1 121.4 97.8 98
southwest comer, final
LIMITATIONS: The test results presented herein were p~pared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no conU'ol. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be r~produced except in full without the written approval of Rone Engineers, Ltd.
07DD Page 1 of 2
Report No.: 176094
Project No.: 037333
Client: Duke Realty Services, LP
RoneEngineers
~l
Technician: Lanny Gist
Report Distribution:
(1) Duke Realty Service, LP
(1) Duke Realty Services, LP
(1) City of Coppell Building Dept.
(1) Pacheco Koch Consulting Engineers
LIMITATIONS: The test results presented herein wer~ prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by pe~ons or conditions over which we have no control. Our letters and
~ports are for the exclusive use of thc clients to whom they are addressed and shall not be reproduced except in full without the written approval of Ron¢ Engineers, Ltd.
07DD Page 2 of 2