Loading...
Freeport NIP(7.0)-LR030424 (2)RoneEn g 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: Duke Realty Services, LP Arm: Mr. JeffLangston 5495 Belt Line Road, Suite 360 Dallas TX 75254 RePort No.: 175015 Project No.: 037333 Date of Service: 04/16/2003 Report Date: 04/24/2003 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the Placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. com~AcroR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter Concrete PLANT: On site SPECIFICATION REQUIREMENTS STRENCTH: 4000 psi ~ 28 Days SLUMP (in): 5" - 7" AIR (%): TEST METHOD: NA ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA MIX DESIGN I.D.: 9361 PLACEMENT DATE: 04/16/2003 WEATt~R CONDITIONS: Sunny TIME SAMPLED: 12:39pm BATCHTIM~: 12:llpm TEMPERATURE (F) - AIR 82 F CONCRETE: 82 F TaUC~CNO: 109 TICK~TNO: 113688 Am CONTENT (%): NA UNIT WEIGHT (PC0: NA OVERALL PLACEMENT LOCATION: Please refer to report #175014 for column lines to all the piers drilled today SAMPLE LOCATION: LineD-Il and D-12 REPORT Og TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) SET NO. 1 1 1 2 1 3 1 4 MEASURED MAXIMUM SLUMP DATE AGE LOAD (inches) TESTED (days) Obs. force) 4.75 04/23/2003 7 4.75 05/14/2003 28 4.75 05/14/2003 28 4.75 06/11/2003 56 See report #175014 for technician time. Technician: Rick Smith Report Distribution: (I) Duke Realty Services, LP (1) Duke Renlty Services, LP (I) City of Coppell Building Dept. (1) Potter Concrete Smrt~: Finished: (I) Pacheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Engineering Dept. 112370 COMPRESSIVE STRENGTH FRACTURE (psi) TYPE 3970 UnbondedCap Unbonded Cap Unbonded Cap Unbonded Cap K. Scott Watsoz CMT Operations Mana er LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or condilions over which we have no control. Our letters and reports are for the exclusive use of the clients m whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DK Page 1 of 1