Freeport NIP(7.0)-LR030502 gineers 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: Duke Realty Services, LP Attn: Mr. JeffLangston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Report No.: 175473 Project No.: 037333 Date of Service: 04/23/2003 Report Date: 05/02/2003 Project: Services: Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fxesh concrete at the placement locations, perform required field testing, cast compressive s~rength samples and bring samples back to the laboratory for curing and testing in accordance w~th applicable standards. PROJECT DATA CONTRACTOR: Duke Realty Services, LP CONCRETE sUPPLIER: Potter PLANT: 2 SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi ~ 28 Days SLUMP (in): 3" - 5** AIR (%): TEST METHOD: NA ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 MIX DESIGN I.D.: 9349 PLACEMENT DATE: WEATHER CONDITIONS: TIME SAMPLED: 9:30am TEMPERATURE (F) - AIR TRUCK NO: 109 AIR CONTENT (%): NA 04/23/2003 Overcast BATCH TIME: 9:03am 62 F CONCreTE: 75 TICHET NO: 114009 UNIT WEIGHT (peO: OVERALL PLACEMENT LOCATION: Tie beam, Line P between Lines 4 and 5, Section 2 SAMPLE LOCATION: Entire beam REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MARKED SLUMP SET NO. (inches) 1 1 5.00 1 2 5.00 1 3 5.00 1 4 5.00 Technician: Lanny Gist Report Distribution: (1) Duke Realty Services, LP (1) Duke Realty Services, LP (1) City of Coppell Building Dept. ( 1 ) Potter Concrate MAXIMUM DATE AGE LOAD TESTED (days) 01r~. force) 04/30/2003 7 05/21/2003 28 05/21/2OO3 28 06/18/2003 56 117765 Started: 9:00am Finished: lhOOam (1) Paeheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Engineering Dept. COMPRESSIVE STRENGTH FRACTUR~ (psi) ~'PE t 4160 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap / ' - - K. Scott Watson CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in foil without the written approval of Rone Engineers, Ltd. 01DK Page 1 of I RO ' :eers neEnilgin 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothwny, Ste. 150, Houston, TX 77040 Corporate Phone: (:214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: Duke Realty Services, LP Attn: Mr. JeffLangston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Report No.: 175434 Project No.: 037333 Date of Service: 04/23/2003 Report Date: 05/02/2003 Project: Services: Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS srRENcrm 4000 psi ~ 28 Days SLUMP (in): 5" - 7" MIXDESIGN I.D.: 9361 PLACEMENT DATE: 04/23/2003 W~ATHER CONDITIONS: Cloudy TIMESAMELED: ll:03am RATe. TIME: 10:41am TEMPERATURE (P) - AIR 72 F CONCRETE: 75 F ~aR (%): NA TEST METHOO: ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C=138 ASTM x~ucx NO: 109 TICKET NO: 114013 AIR CONTENT (%): NA t~UT wmarrr (p~0: NA OVERALL PLACEMENT LOCATION: Please refer to report #175433 for column lines to all the piers drilled today Lines P-13, Q-IS and R-13 SAMPLE LOCATION: C-39 REPORT OF TE~TS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MARKED SET NO. MEASURED SLUMP 0nches) MAXIMUM COMPRESSIVE DATE AGE LOAD STRENGTH FRACTURE TESTED (days) Obs. force) (psi) TYPE 1 1 5.25 04/30/2003 7 1 2 5.25 05/21/2003 28 1 3 5.25 05/21/2003 28 1 4 5.25 06/I 8/2003 56 See report #175433 for technicia~ time. Technician: Rick Smith Report Distribution: (1) Duke Realty Sexvices, LP (1) Duke Realty S~rvicez, LP (1) City of Ceppell Building Dept. (1) Potter Concret~ Started: Finished: (1) Pacheco Koch Consulting Engineers (1) Engineafing Analyst (1) City of Coppell Engineering Dept. 138680 4900 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap K. Sec ,tt Watson CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by pemons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DK Page I of I RoneEngineers 8908 Ambassador Row, Dalla% TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: Duke Realty Services, LP Attn: Mr. SeffLangston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Report No.: 174181 Project No.: 037333 Date of Service: 04/03/2003 Report Date: 05/02/2003 Project: Services: Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA co~cTom Duke Realty Services, LP CONCRETE SUPPLIER: Potter Concrete Ltd. PnnNT: On site SPECIFICATION REQUIREMENTS STRENCTH: 4000 psi @ 28 Days SLUMP (in): 5" - 7" ~an (%): NA TEST METHOD: ASTM C- 172 ASTM C-3! ASTM C-143 ASTM C-231 ASTM C- 1064 ASTM C-138 ASTM C-39 MIX DESIGN I.D.: 9361 PLACEMENT DAT~: 04/03/2003 WEATI-I~R CONDITIONS: Overcast TIME SAMPLED: 12:35pm BATCHTIME: 12:19pm TEMPERATURE (P) - AIR 72 V CONCRETe: 78 TRUCKNO: 101 TICKETNO: 113561 AIR coNTEwr (%): NA traiT W~IGHT Loc0: NA OVERALL PLACEMENT LOCATION: Drilled pier locations at office area/section #1 SAMPLE LOCATION: Pier locations E.4/3, D.9/3 REPORT OF TE~qT~q and D.f/3 Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MARKED SLUMP DATE SET NO. (inches) TESTED 1 1 5.25 04/10/2003 MAXIMUM COMPRESSIVE AGE LOAD STRENGTH FRAcTuRE (days) Obs. force) (psi) TYPE 7 119140 4210 Unbonded Cap 1 2 5.25 05/01/2003 1 3 5.25 05/01/2003 28 149110 28 152840 Average 5270 UnbondedCap 5410 UnbondedCap 5340 1 4 5.25 05/29/2003 56 Unbonded Cap Water added at site: 5 gallons See report #174180 for technician time. Technician: Rick Smith Report Distribution: (1) Duke Realty Services, LP (1) Duke Realty Services, LP (1) City of Coppell Building Dept. (1) Potter Concmm Started: Finished: (1) Pacheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Engineering Dept. K. Scott Watson CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variatioo in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Ronc Engineers, Ltd. 01DK Page I of I