Loading...
ST9401-LR 980130 (2)CLIENT: S.J. Louis Construction PROJECT: Denton Tap Road REPORT DATE: 01/30/98 TMI REPORT NO.: Dc97~044-69 SPECIFICATIONS Percent Compaction: 95+ Moisture Content (%): Opt -2 to +5 ~TERRA-MAR, INC. ~ GEOTECHNICAL ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON LONGFlEW LUBBOCK AUSTIN 11050 Ables Lane, Dallas, Texas 75229 Phone:972-488-8800 SOIL MOISTURE -DENSITY TEST REPORT IN-PLACE TESTS BY NUCLEAR METHODS DISTRIBUTION: S. J. Louis Construction - Bruce Shear City of Coppell - Garth Campbell CURVE TEST NO. METHOD 2 ASTM D 698 3 ASTM D 698 1 ASTM D 698 Date Tested: Technician: MATERIAL REFERENCE CURVE DATA MATERIAL DESCRIPTION Tan Sandy Clay with Limestone Fragments Tannish Sandy Clay with Gravel Brown Sandy Clay with Gravel TEST DATA 01/28/98 M. Kashem OPTIMUM MOISTURE (%) 23.5 14.7 19.7 TEST ELEVATION NO. OR LIFT IN-PLACE TEST RESULTS DENSITY AND MOISTURE TESTS ARE PER ASTM D2922, D3017, RESPECTIVELY REF. % DRY LOCATION CURVE MOISTURE DENSITY MAX. DRY DENSITY (pet'} 94.9 114.8 106.2 % DENSITY 1 1' B.G. 2 .5' B.G. 3 Grade 4 1' B.G. 5 .5' B.G. 6 Grade 7 2' B.G. 8 Grade Lateral at Southbound A-5 Lateral at Southbound A-5 Lateral at Southbound A-5 Lateral at Southbound A-8'< Lateral at Southbound A-8 ( -"D (¢~ Lateral at Southbound A-8~ Lateral at Southbound A-11 Lateral at Southbound A-11 2 24.3 94.3 99.4 3 16.0 110.6 96.3 3 16.4 111.9 97.5 1 20.0 105.5 99.3 3 15.8 109.7 95.6 3 16.1 111.4 97.0 3 15.6 110.8 96.5 3 15.3 110.6 96.3 GAUGE I.D.: 10903 STD. DENSITY COUNT: "R" AFTER TEST NUMBER INDICATES RETEST. * INDICATES FAILURE TO COMPLY WITH PROJECT SPECIFICATIONS REMARKS: Note: This report is for the exclusive use of the Client addressed. This report may not be reproduced except in its entirety, without the written consent of TMI. Results apply only to above tests. 2399 STD. MOISTURE COUNT: 601 t !l! "! [] ,:,.