PA0101-LR020924ALPHA TESTING, INC. 2200 Wisconsin St., Suite 100 Do#as, Texos 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR JMC CONSTRUCTION DATE: 09/24102 McKINNEY, TEXAS PROJECT COPPELL TRAIL SECTIONS OUR REPORT NO.: 02660-17 COPPELL, TEXAS TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATEDEPTH~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % ~CF % PCF 15 09/24/02 FG 1 17.0 108 19.6 106 98 1 -A 16 09/24/02 FG I 17.0 108 21.0 104 96 1-A 17 09/24/02 FG I 17.0 108 20.4 106 98 1-A TEST LOCATION: I 15 !SIDEWALK TRAIL SECTION #3 AT STATION 19+00 16 SIDEWALK TRAIL SECTION #3 AT STATION 16+00 17 SIDEWALK TRAIL SECTION #3 AT STATION 13+00 CC: SCHRICKEL, ROLLINS AND ASSOCIATES, INC.; THE CITY OF COPPELL 1. FILL * A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2 NATURAL SUBGRADE B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS Re¥~fully 3 LIME STABILIZED C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4 CEMENT TREATED D RETEST Our test results & reports are for the exclusive use of the Chant (and t~eir designated recipients on hie in our office) and shall not be reproduced and/or dfstrll~uted~cJpt withYxpress approval of ALPHA. The use of our name & test results must recefve our wrffien applova~ Test results & reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens Geotechnical Engineering · Construction Materials Testing · Environmental Engineering · Consulting