PA0101-LR030113Client:
Project:
GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS
DALLAS FORT WORTH HOUSTON AUSTIN LONGWEW
11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488.8800 fax:(972) 488-8080
JMC Construction, L.P.
Coppell Trails
363 N. Denton Tap Road
TMI Report No.: DC02-115-045
Report Date: 01/13/2003
Concrete Compression Test Report
Report Distribution: (1) City of Coppell (1) City of Coppell
(1) Schrickel, Rollins & Assocs., Inc.
(1) JMC Construction, LP
Specifications
Strength 3000 psi @ 28 Days Placement Date
Slump 4 in max Sampled By
Air Content 6 % max Weather
Concrete Temperature n/a Supplier/Mix
Ambient Temperature n/a Air Content Method
Test Data
01/03/2003
Mohammed A. Kashem
Clear
Lattimore Materials/864
ASTM C-231-B
Ticket Number: 7122613 Time Batched: 1:31 pm
Slump: 4 in Air Content: 4.6 %
Concrete Temperature: 70° F Ambient Temperature: 60° F
Placement Location: Culvert at Chat Trail #2
Sample Location: At East half
Time Sampled: 2:15 pm
Unit Weight: n/a
Yardage (c.y.): 7 of 27
Age, Max Load Area Strength Fracture
Set # Cyl~der Test Date (dayst (lbs. force) (sq.in.) (psi) Type
I cpt01030301 01/10/2003 7 123020 28.27 4350
1 cpt01030302 01/31/2003 28
1 cpt01030303 01/31/2003 28
Normal cylinder size: 6" x 12"
Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231.
unbonded cap
TERRA-MAR, INC.
/// Mike Fuller t/ !
/Project Manager
The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of
this report, or any part therein, is stdctly prohibited without the express wdtten consent of TMI.
OlSSD Pa~¢ ] or' I