CONCRETE COMPRESSIVE STRENGTH TEST
Client:
Duke Realty Services, LP
Atta: Mr. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 179038
Project No.: 037333
Date of Service: 06/23/2003
Report Date: 07/01/2003
Project:
Services:
Freeport 10
500 Freeport Parkway
CoppeH, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
STRENGTH:
SLUMP (in):
Am (%):
TEST METHOD:
COnXaACrOm Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLA~T: On site
SP~.Cn~CA~ON REQvmz~lz~rrs
4000 psi ~ 28 Days
5" maximum
3% - 6%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
rmx DZS~GN ~.: 7752
PLACEMENT DATE: 06/23/2003
~A~R CO~ITIONS: Sunny
T~ S~LED: 7:10~ BAT~ ~: 6:46~
TEMPE~TU~ ~ - A~ 85 F CON~: 83 F
xa~o: 104 ~c~ ~o: 116001
~nco~TE~ (%): 2.2 ~T ~G~ ~0: NA
O~L P~CE~ LOCA~ON:
Pang - sou&~t fi~e, app~ch, ~u~ ~lf of ~u~ ~ng lot be~e~ b~l~ng
colu~ 1~ 5 ~ DD
SAMPLE LOCATION: 6' east by 2' south fi.om northwest
comer of approach
ASTM C-39 REPORT ON TEgTg
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
CYLINDER MEASURED
MARleD SLUMP DATE
SET NO. (inche~) TESTED
1 1 3.5 06/30/2003
MAXIMUM COMPRESSIVE
AGE LOAD STRENGTH I~ACTURE
(days) Obs. force) (psi) TYPE
7 127340 4500
1 2 3.5 07/21/2003 28
1 3 3.5 07/21/2003 28
1 4 3.5 08/18/2003 56
Unbonded Cap
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(compos/tion, appearance, performance, etc.) or any other feature of similar subject matter provided by peraons or conditions over which we have no control, Our letters and
reports are for thc exclusive usc of the cheats to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01DD Page 1 of 7
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Client:
Project:
Services:
Duke Realty Services, LP
Attn: Mr. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 179038
Project No.: 037333
Date of Service: 06/23/2003
Report Date: 07/01/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples end bring
samples back to the laboratory for curing end testing in accordance with applicable standards.
PROJECT DATA
ColvrRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT: OI1 site
SPECIFICATION REQUIREMENTS
SrRENCTrI: 4000 psi @ 28 Days
SLUMP (in): 5'* maximum
Am (%):
TEST METHOD:
3% - 6%
ASTM C~172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
MIX DESIGN I.D.: 7752
pr~cEME~r DATE: 06/23/2003
WEATHER CONDITIONS: Sunny
~s~D: 8:15~ BATCHES: 7:56~
~E~-~ 88 F CON~: 85 F
xavc~ ~o: I04 Tic~x ~o: 116011
~a conTE~ (%): 1.9 ~x ~G~ ~0: NA
O~L PLACE~ L~A~ON:
Pav~g - ~u~t fi~ spproac~ sou~ ~fof ~u~ p~ng lot be~ build~g
column lin~ 5 to DD
SAMPLE LOCATION: 45' east by 3' south from northeast
comer of approach
ASTM C-39 REPORT OF TEgTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
CYLINDER MEASURED MAXIMUM COMPRESSIVE
MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE
SET NO. ' (inches) TESTED (days) (lbs. force) (psi) TYPE
2 1 4.0 06/30/2003 7 123275 4360 Unbonded Cap
2 2 4.0 07/21/2003 28 Unbonded Cap
2 3 4.0 07/21/2003 28 Unbonded Cap
2 4 4.0 08/18/2003 56 Unbonded Cap
LIMITATIONS: The test results pres~mted herein we~ prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no conU'ol. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Roue Engineem, Ltd.
01DD Page 2 of 7
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Client:
Project:
Services:
Duke Realty Services, LP
Aria: Mr. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 179038
Project No.: 037333
Date of Service: 06/23/2003
Report Date: .-07/01/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast comp~ssive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
CONTRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Pot~er
PLANT: On site
SPECnnCATION REQt~.~MENTS
sxmgNaTi~: 4000 psi ~ 28 Days
SLUMP (in): 5" maximum
AIR (%):
TEST METHOD:
3% - 6%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
M~X DESla~ I.D.: 7752
PLACEMENT DATE: 06/23/2003
WEATHER CONDITIONS: Sunny
TIME SAMPLED: 9:50am BATCH TIM~: 9:28am
TEMPERATURE (F) - AIR 92 v CONCRETE: 88 v
?RUCK NO: 104 TIC~a~T ~O: 116021
,UR CONTENT (%): 4.5 U~T WZla~X (pc0: NA
OVERALL PLACEMENT LOCATION:
Paving - southeast firelane, approach, south half of south parking lot betwe~ building
colunm lines 5 to DD
SAMPLE LOCATION: 110' east by 4' south from
northwest comer of approach
ASTM C-39 REPORT Ol~ TE~TS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
CYLINDER
MARKED
SET NO.
3 1
3 2
3 3
3 4
MEASURED MAXIMUM COMPRESSIVE,
SLUMP DATE AGE LOAD STRENGTH ][~P..~(.-I't~P.~
(inches) TESTED (days) Obs. force) (psi) TYPE
4.25 06/30/2003 7 104475 3690 Unbonded Cap
4.25 07/21/2003 28 Unbonded Cap
4.25 07/21/2003 28 Unbonded Cap
4.25 08/18/2003 56 Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
~'potts are for the exclusive use of the clients to whom they am addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
O1DD Page 3 of 7
R n.eEng
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
CHent:
Project:
Services:
Duke Realty Services, LP
Atto: Mr. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 179038
Project No.: 037333
Date of Service: 06/23/2003
Report Date: 07/01/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of frgsh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
CONTRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT: On site
SPECIFICATION REQUH~MENTS
ST~NGTH: 4000 psi @ 28 Days
SLUMP (in): 5** 1Tlaxil~un3.
AIR (%):
TEST M~THOD:
3% - 6%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 06/23/2003
WEATHER CONDITIONS: Sunny, party cloudy
?~m SAM~LEO: 11:05am BATCH TLME: 10:45am
TEMPERATURE (F) - AIR 91 F CONCRETE: 88 P
TRVCK NO: 104 ~C~T NO: 116031
AIRCONTENT (%): 3.9 UNIT WEIGHT (pcf): NA
OVERALL PLACEMENT LOCATION:
Paving - southeast fimlane, approach, south half of south parking lot between building
COJnm~ lines 5 to DD
SAMPLE LOCATION: 35' west by 4' soUth from noxtheast
comer of approach
ASTM C-39 REPORT OF TF, gT~
Concrete Compressive Cylinder 6" x ! 2" (area 28.27 sq. in.)
CYLINDER
MARKED
MEASURED MAXIMUM COMPRESSIVE
SLUMP DATE AGE LOAD STRENGTH
SET NO. 0nches) TESTED (days) Obs. force) (PS0
4 1 4.75 06/30/2003 7
4 2 4.75 07/21/2003 28
4 3 4.75 07/21/2003 28
4 4 4.75 08/18/2003 56
95400 3370
Unbonded Cap
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented he,in were prepmed based upon thc specific samples provided for testing. We assume no ~sponsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions ove~ which we have no control. Our letters and
reports are for the exclusive use o£the clients to whom they are addressed and shall not be x~roduced except in full without the wfitte~ approval of Rone Engineers, Ltd.
01DD Page 4 of 7
R eE ng i neers
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fart Worth, TX 76118
6300 Rothway, ate. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Client:
Pro~ect:
Services:
Duke Realty Services, LP
ARm Mr. JeffLangston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 179038
Project No.: 037333
Date of Service: 06/23/2003
Report Date: 07/01/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the labo~ttory for curing and testing in accordance with applicable standards.
co.tv. ActoR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT: On site
SPRCIFICATION REQUIREMENTS
STRENGTH: 4000 psi ~ 28 Days
SLUMP (in): 5" maximum
Am (°/4:
TEST METHOD:
3% - 6%
ASTIVl C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C- 1064
ASTM C-138
PROJECT DATA
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 06/23/2003
WEATHER CONDITIONS: Sunny, partly cloudy
~IMZSAMPLED: 12:45pm aATC-~TU~m: 12:23pm
TEMPERATURE (F) - AIR 92 F CONCRETE: 87 F
TRVCI~NO: 106 TIC~T NO: 116041
AIR CONTENT (%): 4.8 UNIT WEIGHT (pc0: NA
OVERALL PLACEMENT LOCATION:
Paving - southeast firelane, approach, sou~h half of south parking lot between building
colunm lines 5 to DD
SAMPLE LOCATION: 25' west by 20' south from
northwest comer of parking lot
ASTM C-39 REPORT ON TEgT~
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
CYLINDER MEASURED MAXIMUM COMPRESSIVE
MAP. I~D SLUMP DATE AGE LOAD STRENGTH FRACTURE
SET NO. 0nches) TESTED (days) Obs. force) (psi) TYPE
5 1 4.25 06/30/2003 7 110785 3920 Unbonded Cap
5 2 4.25 07/21/2003 28 Unbonded Cap
5 3 4.25 07/21/2003 28 Unbonded Cap
5 4 4.25 08/18/2003 56 Unbonded Cap
LIMITATIONS: The teat results presented herein were prepared based upon the specific samples prox, ided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no con~'ol. Oar letters and
reports are ~r the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01DD Page 5 of 7
RoneEn.g.
8908 Ambassador Row, D~Has, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
CHeat:
Duke Realty Services, LP
At'm: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Report No.: 179038
Project No.: 037333
Date of Service: 06/23/2003
Report Date: 07/01/2003
Project:
Services:
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
CONTRACTO~a Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT: On site
SPECIFICATION REQUIREMENTS
ST~NGTH: 4000 psi ~ 28 Days
SLUMP (in): 5" maximum
AIR (%):
TEST METHOD:
3% - 6%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-I064
ASTM C-138
PROJECT DATA
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 06/23/2003
WEATHER CONDITIONS: Suln_ny
TOtE S~OI~D: 1:45pm BATCH rn~: 1:28pm
TEMPERATURRO~)-AIR 91 v co~cRETE: 88 F
TRUCK NO: 113 TICKET NO: 116051
AIR CONTENT (%): 4.0 UNIT WEIGHT (pc0: NA
OVERALL PLACEMENT LOCATION:
Paving - sou~hesst firelane, approach, south haft of south parking lot between building
column lines 5 to DD
SAMPLE LOCATION: 150' west by 15' south from
northwest comer of parking lot
ASTM C-39 REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
CYLINDER
MARKED
SET NO.
MEASURED
SLUMP DATE
(inches) TESTED
MAXIMUM COMPRESSIVE
AGE LOAD STRENGTH FRACTURE
(dnys) Obs. force) (psi) TYPE
6 1 4.25 06/30/2003
'6 2 4.25 07/21/2003
6 3 4.25 07/21/2003
6 4 4.25 08/18/2003
7 119455 4220 Unbonded Cap
28 Unbonded Cap
28 Unbonded Cap
56 Unb0nded Cap
LIMITATIONS: The test ,a~mlts presented herein were prepar~l based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clieats to whom they are addressed and shall not be reproduced except in full without thc vninen approval of Ronc Engineers, Ltd.
01DD Page 6 of 7
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rathway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEsT
Client:
Project:
Services:
Duke Realty Services, LP
At~m: Mr. JeffLangston ·
5495 Belt Line Road, Suite 360.
Dallas TX 75254
Report No.: 179038
Project No.: 037333
Date of Service: 06/23/2003
Report Date: 07/01/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing cast compressive sffength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
CO~CrP. ACTOa: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
r~r: On site
SPECIFICATION REQUIREMENTS
STRENGTH: 4000 psi ~ 28 Days
sun On): 5" maximum
AIR (%):
TEST METHOD:
3% - 6%
ASTM C-172
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064
ASTM C-138
rmx DESIGN I.n.: 7752
PLACE~m~r rATE: 06/23/2003
W~ATHER CONDITIONS: S~mny
~S~L~: 3:05pm aAXCn~: 2:27pm
~MP~T~-~a 95 ~ COn~: 89 V
TRU~ NO: 113 T~C~T ~O: 116061
~R cONTENT (%): 4.3 ~T ~IG~ ~0: NA
O~LL PLACE~ LOCA~ON:
Pang - mu~t ~e, appm~ ~u~ barfer ~u~ p~ng lot be~ bulldog
col~ lia~ 5 to DD
SAMPLE LOCATION: 25' east by 15' south fi'om
northwest comer of parking lot
ASTM C-39 REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
CYLINDER
MARleD
SET NO.
MEASURED MAXIMUM
SLUMP DATE AGE LOAD
0nches) TESTED (days) 0b~ force)
COMPRESSIVE
STRENGTH I~ACTURE
(~a) T~E
7 1 3.75
7 2 3.75
7 3 3.75
7 4 3.75
Technician: Jeremy Watts
Report Distribution:
(1) Duke Realty Scrvicca, LP
(1) Duke Realty Services, LP
(1) City of Coppell Engineering Dept.
(1) Potter Concrete
06/30/2003 7
07/21/2003 28
07/21/2003 28
08/18/2003 56
97675
Started: 6:30am Finished: 4:30pm
(1) Paoheco Kooh Consulting Engineers
(1) Engineering Analyst
(1) City of Coppell Bldg. Inspections
3450 Unbonded Cap
Unbonded Cap
Unbonded Cap
/~ Unbonded Cap
K. Scott Watson, AET
CMT Operations Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, apPexmnce, performance, etc.) or any other feature of similar subject matter provided by persons or cond/tions over which we have no control. Our letters and
reports are for the exclusive use of the ¢liants to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01DD Page 7 of 7