ST0202-CS030528r ] Wednesday, May 28, 2003 PRELIMINARY PLAN REVIEW DISAPPROVAL Ken Griffin City of Coppell 255 Parkway Blvd. Coppell, Texas 75019 RE: P-PRE050329 Bethel School Road Project#ST 02-02 100 Block of BethelSchool Road Coppell, Texas 75019 Dear Mr. Griffin: Enclosed are the results of the preliminary plan review completed on the above referenced project. Identified on the worksheet(s) are areas of nonconformance with accessibility standards adopted by the Texas Department of Licensing and Regulation for purposes of ensuring compliance with Article 9102, Texas Civil Statutes. However, this preliminary review will not be filed with the state. This determination does not address applicability of the Americans with Disabilities Act (ADA), P.L. 101-336), or any other state, focal, or federal requirement. For information on the ADA call the ADA Hotline, (800)949-4232, the United States Department of Justice at (202)514-0301or our office directly. Questions may be directed to our office at (972)434-0068 Please reference the PRE number in any correspondence pertaining this report. Sincerely, R~ B. Card. en~ Randal B. Carden Accessibility Specialist #137 rcarden@accessology.com Enclosure: Preliminary Plan Review Report PRELIMINARY PLAN REVIEW REPORT Preliminary Plan Review Report .~Lrticle 9102, T.C.S. Texas Accessibility Standards Preliminary Review: Not to be submitted ACCESSOLOGY, INC. NO: P-PRE050329 PAGE: i PROJECT: BETHEL SCHOOL ROAD PROJECT # ST 02-02 FACILITY: BETHEL SCHOOL ROAD ADDRESS: I00 BLOCK OF BETHEL SCHOOL ROAD BETWEEN HEARTZ TO DENTON TAP, COPPELL OWNER: CITY OF COPPELL ARCHITECT: CITY OF COPPELL REVIEWER: Randal B Carden RAS#: 137 DATE: May 28, 2003 PROJECT NOTES: PROJECT SCOPE: TAS 4.1.2 PROJECT DESCRIPTION: Rebuild the existing road from Heartz, to Denton Tap. Add left turn lane at Denton Tap Road. Replace selected brick pavers. Repair (removal of existing and replace with new) approximately 15feet of sidewalk. ACCEPTABLE 4.3.2 LOCATION ACCEPTABLE 4.3.3 WIDTH ACCEPTABLE 4.3.4 PASSING SPACE ACCEPTABLE 4.3.5 HEAD ROOM ACCEPTABLE* 4.3.6 SURFACE TEXTURES *Except as noted in 4.5.1 The surface of an accessible route shall comply with 4.5. and 4.7.4 PLEASE VERIFY 4.3.7 SLOPE An accessible route with a running slope greater than 1:20 is a ramp and shall comply with 4.8. Nowhere shall the cross slope of an accessible route exceed 1:50. NOTE: The cross slopes of the sidewalk repair and slopes & cross slopes of the curb ramps are not noted in the plans provided for review. Please ensure that the cross slopes of the repaired sidewalks do not exceed 2%. Please ensure that the slopes of curb ramps do not exceed 1:12. If new sidewalks are provided, please ensure that cross slopes do not exceed 2%. The slope of public sidewalks may follow the slope of the road and ~the requirement for ramps where this slope exceeds 1:20 (5%) does not apply. ACCEPTABLE* 4.3.8 CHANGES IN LEVELS *Except as noted in TAS Changes in level along an accessible route shall comply with 4.5.2. If an ac- Section 4.7 cessible route has changes in level greater than t/2", then a curb ramp, ramp, elevator, or platform lift (as permitted in 4.1.3 and 4.1.6) shall be provided. An accessible route does not include stairs, steps, or escalators. See definition of "egress, means of" in 3.5. NOTE: Curb ramps are not detailed. Please verify compliance with sec- tion 4.7 with the submission of the final plans. NA 4.3.9 DOORS NA 4.3.10 EGRESS NA 4.3.11 AREAS OF RESCUE ASSISTANCE 4;4 PROIRUD~GOB.JECTS.,: NONE NOTED 4.4.1 GENERAL ACCEPTABLE 4.4.2 HEAD ROOM PRELIMINARY PLAN REVIEW Preliminary Plan Review Article 9102, T.C.S Texas Accessibility Standards Preliminary Review: Not to be subrrfitted ACCESSOLOGY, INC. NO: P-PRE050329 PAGE: 2 PROJECT: BETHEL SCHOOL ROAD PROJECT # ST 02-02 OWNER: CITY OF COPPELL ARCHITECT: CITY OF COPPELL REVIEWER: Randal B Carden RAS#: 137 DATE: May 28, 2003 PLEASE ENSURE 4;5 GROUND!~FLOOR SURFACES 4.5.1 GENERAL Ground and floor surfaces along accessible routes and in accessible rooms and spaces including floors, walks, ramps, stairs, and curb ramps, shall be stable, firm, slip-resistant, and comply with section 4.5. Soft or loose materials such as sand, gravel, bark, mulch or wood chips are not suitable. Cobblestone and other irregular surfaces having a texture that constitutes an obstacle or hazard, such as improperly laid flagstone, shall not be a part of accessible routes, spaces and elements. NOTE: Brick pavers are provided on the accessible routes of travel. Please ensure that the pavers meet the requirements of this section and Section 4.5.2 (Changes in Level) below. PLEASE ENSURE 4.5.2 CHANGES IN LEVEL Changes in level up to %" may be vertical and without edge treatment. Changes in level between %" and 1/2" shall be beveled with a slope no greater than 1:2. Changes in level greater than V2" shall be accomplished by means of a ramp that complies with 4.7 or 4.8. NA 4.5.3 CARPET NONE NOTED 4.5.4 GRATINGS NONE NOTED PLEASE VERIFY 4.7.1 LOCATION Curb ramps complying with 4.7 shall be provided wherever an accessible route crosses a curb. NOTE: It is difficult to evaluate this section with the information pro- vided in the preliminary plans. Sheet 5 appears to indicate that a cross- walk is provided using brick pavers and concrete curbs, but curb ramps are not provided. This practice presents an architectural barrier to those individuals who use wheelchairs and is unacceptable to the TAS and public law. Please provide additional information to verify compliance to ali requirements of this section with the submission of the final plans. Please note that curb ramps require surface textures and light reflective values (color) that contrast significantly with the adjacent pedestrian routes. PLEASE VERIFY* 4.7.2 SLOPE *See note in 4.7.1 Slopes of curb ramps shall comply with 4.8.2. The slope shall be measured as shown in Fig. 11. Transition from ramps to walks, gutters, or streets shall be flush and free of abrupt changes. Maximum slopes of adjoining gutters, road surface immediately adjacent to the curb ramp, or accessible route shal! not exceed 1:20 (5%). PLEASE VERIFY* 4.7.3 WIDTH *See note in 4.7.1 The minimum width of a curb ramp shall be 36", exclusive of flared sides. PRELIMINARY PLAN REVIEW Preliminary Plan Review Article 9102, T.C.S. Texas Accessibility Standards Preliminary Review: Not to be submitted ACCESSOLOGY, INC. NO: P-PRE050329 PAGE: 3 PROJECT: BETHEL SCHOOL ROAD PROJECT # ST 02-02 OWNER: CITY OF COPPELL ARCHITECT: CITY OF COPPELL REVIEWER: Randal B Carden PLEASE VERIFY* *See note in 4.7.1 PLEASE VERIFY* *See note in 4.7.1 NONE NOTED PLEASE VERIFY* *See note in 4.7.1 4.7.4 SURFACE RAS#: 137 DATE: May 28, 2003 Surfaces of curb ramps shall comply with section 4.5 above. (1)Textures shall consist of exposed crushed stone aggregate, roughened con- crete, rubber, raised abrasive strips, or grooves extending the full width and depth of the curb ramp. Surfaces that are raised, etched, or grooved in a way that would allow water to accumulate are prohibited. (2) For purposes of warning, the full width and depth of curb ramps shall have a light reflective value and texture that significantly contrasts with that of ad- joining pedesthan routes. 4.7.5 SIDES OF CURB RAMPS If a curb ramp is located where pedestrians must walk across the ramp or where it is not protected by handrails it shall have flared sides; the maximum slope of the flare shall be 1:10. Curb ramps with returned curbs may be used where pedestrians would not normally walk across the ramp. 4.7.6 BUILT-UP CURB RAMPS 4.7.8 OBSTRUCTIONS Curb ramps shall be located or protected to prevent their obstruction by parked vehicles. PLEASE VERIFY* 4.7.9 LOCATION AT MARKED CROSSINGS *See note in 4.7.1 PLEASE VERIFY* *See note in 4.7.1 NONE NOTED Curb ramps at marked crossings shall be wholly contained within the mark- ings, excluding any flared sides. 4.7.10 D~GONALCURBRAMPS If diagonal (or comer type) curb ramps have returned curbs or other well- defined edges, such edges shall be parallel to the direction of pedestrian flow. The bottom of diagonal curb ramps shall have 48" minimum clear space as shown in Fig. 15(c) and 15(d). If diagonal curb ramps are provided at marked crossings, the 48" clear space shall be within the markings. If diago- nal curb ramps have flared sides, they shall also have at least a 24" long seg-. ment of straight curb located on each side of the curb ramp and within the marked crossing. NONE NOTED NA NA NA NA NONE NOTED NA NA NA NA 4.18 ~ALS ~:~ 4.19 LAVATORIESAND MIRRORS ~ L~rs) PRELIMINARY PLAN REVIEW Preliminary Plan Review Article 9102, T.C.S. Texas Accessibility Standards Preliminary Review: Not to be submitted ACCESSOLOGY, INC. NO: P-PRE050329 PAGE: 4 PROJECT: BETHEL SCHOOL ROAD PROJECT # ST 02-02 OWNER: CITY OF COPPELL ARCHITECT: CITY OF COPPELL REVIEWER: Randal B Carden RAS#: 137 DATE: May 28, 2003 NA sa oo i, S NONE NOTED n;26 : 4;27 CONTROES;~O PLEASE ENSU~ 4.27.2 CLEAR FLOOR SPACE Cle~ floor space complying wi~ 4.2.4 that allows a forw~d or p~allel ap- proach by a person using a wheelchair shall be provided at controls, dispens- ers, receptacles, and other operable equipment. Controls and operating mech~isms located in ~coves that ~e deeper th~ 24" require additional m~euvefing ~ea. NOTE: Controls are not specifically noted or de~iled in the plans. Acces- sible controls would include pedestrian reques~ for the traffic signals to change. Please ensure compliance with the submission of the final plans. PLEASE ENSUe* 4.27.3 ~IGHT *See note in 4.27.2 The highest operable p~ of controls, dispensers, receptacles, and other oper- able equipment shall be placed wi~in at least one of the reach r~ges speci- fied in 4.2.5 and 4.2.6. Electhcal and communications system receptacles on walls shall be mounted no less ~an 15" above the floor. EXCEPTION: ~ese requirements do not apply where the use of special equipment dictates othe~ise or where electdc~ and communications sys- tems receptacles ~e not no,ally intended for use by building occupants. PLEASE ENSUe* 4.27.4 OPE~TION *See no~e in 4.27.2 Controls ~d operating mechanisms shall be operable with one hand m~d shall not require tight grasping, pinching, or twisting of the wrist. The force re- quired to activate controls shall be no greater ~an 5 lbf. NONE NOTED NONE NOTED 4;32 ~ OR':B~'~ NA 6.0~ 7.0 BUs'ss ~R~n~m~ NA 7.2 SALES AND SERVICE COUNTERS, TELLER W~DOWS, PRELIMINARY PLAN REVIEW Preliminary Plan Review Articlc 9102, T~C.S. Texas Accessibility Standards Preliminary Review: Not to be submitted ACCESSOLOGY, INC. NO: P-PRE050329 PAGE: 5 PROJECT: BETHEL SCHOOL ROAD PROJECT # ST 02-02 OWNER: CITY OF COPPELL ARCHITECT: CITY OF COPPELL REVIEWER: Randal B Carden RAS#: 137 DATE: May 28, 2003 INFORMATION COUNTERS NA 7.3 CHECK-OUT AISLES ACCEPTABLE 7.4 SECURITY BOLLARDS AND TURNSTILES NA 8.t~:i NA 9.~' NA I0. ~SPORT~'ION ~AC~ITIE$!; PRELIMINARY PLAN REVIEW