Loading...
Park West CC(6)-CS 960307DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: Park West Commerce Center R-gi~~ Lot 2 Block 6 and Block S, to create two new lots that will allow the development of a 320,000 square foot office warehouse facility and a 200,000 square foot office warehouse building, located at the northwest corner of Belt Line Rnad and Wrangler Drive, at the request of Halff Associates, Inc. DRC DATE: February 29, 1996 and March 7, 1996 CONTACT: %n Griffin, P.E., Assistant City Manager/City Engineer (304-3679) COMMENT STATUS: /FINAL ~i~B ~~~-&~ Replat Comments 1. Dedicate right-of-way for south bound deceleration lane (12'x200') at Wrangler/Belt Line. 2. Show fire lanes, visibility triangle easements at all driveways. 3. Water, sanitary sewer and roadway impact fees will be required. 4. Provide Floodplain Administrator's signature block. Site Plan 1. Show medians on Belt Line Road. 2. Show fire lanes. 3. Construct deceleration lanes at all driveways off of Belt line (100' storage w/100' transition 12' wide). 4. Provide south bound deceleration lane 12' wide (100' storage w/100' transition) at Belt Line Road/Wrangler Drive. 5. Provide 45' x 45' corner clip at Belt Line/Wrangler. 6. Provide 40' radius for trucks at driveways adjacent to loading docks. 7. Provide water, wastewater and drainage plans. 8. Any driveways onto Belt Line will be required to have brick pavers.