Loading...
Sandy Lake Med-CS030717CITY OF COPPELL PLANNING DEPARTMENT STAFF REPORT CASE: SANDY LAKE PLAZA MEDICAL BUILDING LOT 1, BLOCK 1, SITE PLAN P & Z HEARING DATE: July 17, 2003 C.C. HEARING DATE: August 12, 2003 STAFF REP.: Marcie Diamond, Assistant Planning Director LOCATION: At the northwest corner of Sandy Lake & Moore Roads SIZE OF AREA: Approximately 2.75 acres of property. CURRENT ZONING: C (Commercial) REQUEST: Site Plan approval for a two story, 30,000 square foot medical building. APPLICANT: The Cirrus Group 1700 Pacific Avenue, Suite 2730 Dallas, Texas 75201 (214) 953 -1722 FAX: (214) 953 -0278 Architect: John Garrison GSR Andrade Architects 4121 Commerce Street, Suite One Dallas, Texas 75226 (214) 824 -7040 FAX: (214) 887 -0559 Item # 5 Engineer: Brandon O Donald Brockette. Davis. Drake 4144 N. Central Expry. Dallas, Texas 75204 (214) 824 -3647 FAX: (214) 824 -7064 Page 1 of 5 HISTORY: This area was preliminary platted as the Sandy Lake Plaza Addition. In the mid 1980's, the lot to the north of the subject tract was final platted as Lot 4 of this addition, and a Site Plan was approved for the Children's World day care center. In 1997, a request for a Special Use Permit for Phillips 66 gas station, convenience store and car wash on 1.2 acres at the northwest corner of Sandy Lake and Moore Roads was recommended for denial by the Planning and Zoning Commission; this case was not appealed to City Council. In 1999, an application for Site Plan and Minor Plat approval for Sav -On Drugs was submitted on the subject property. The application was withdrawn prior to Planning and Zoning Commission consideration. TRANSPORTATION: Sandy Lake Road has recently been improved to a 4 -lane divided thoroughfare, built generally within 95 -feet of right -of -way. Moore Road is a 2 -lane undivided collector street, built within 60- feet of right -of -way. SURROUNDING LAND USE & ZONING: North -Day Care Center; C (Commercial) South - Single - Family homes; SF -12 (Single Family -12) East - vacant and Austin Place residential subdivision; C (Commercial) and PD- 130 -SF -7 West - Sandy Lake Road Baptist Church; SF -12 (Single Family - 12) COMPREHENSIVE PLAN: The 1996 Comprehensive Master Plan shows this property as suitable for Neighborhood Retail. DISCUSSION: This request is to allow for the development of a two - story, 30,000 square -foot medical office building, with 172 parking spaces. As discussed in the HISTORY section of this report, various developments have been proposed on this tract (gas station and drug store), and this proposed medical building is a preferable use. The proposed Site Plan is in compliance with the zoning regulations in terms of setbacks, parking, signage and building height. As shown on the Landscape Plan, plant Item # 5 Page 2 of 5 materials are in eg_neral compliance with City ordinances in terms of area devoted to landscaping and quantities. The only issue is along the western property line of this tract, where, per ordinance, 13 trees (one per 40- linear feet, adjacent to residential zoning) are required. Given this residential adjacency, a 6 -foot masonry screening wall is also required; however, there is an existing 15' TP &L easement running parallel to this western property line, where there are overhead power lines and a tree row. The preliminary response from TP &L (Oncor) is that they will allow for parking and the required screening wall within this easement; however, they expressed concern over the planting of new trees under the existing power lines, as required by the Zoning Ordinance. As previously stated, there is an existing tree row along the western property line consisting of nine, 8- caliper inch Hackberry trees, which provides a fairly dense visual screen. However, due to the size and species, these trees may be removed without mitigation, which is indicated as such on the plan. The only tree subject to mitigation is the 20" Hackberry located in the southeastern portion of the site. The applicant has proposed to mitigate the removal of this tree through the upsizing of 10 of the required three- caliper inch to 4- caliper inch trees. The issues relating to this western property line are: • Thirteen 3- caliper inch trees are required along the western property line. • A six -foot screening wall is also required, due to the adjacency of residential zoning, even though the property is developed with a non - residential use (church). • TP &L (Oncor) is reluctant to allow new trees to be planted in their easement, due to the overhead power lines. • The existing nine Hackberry trees could be preserved to fulfill a portion of the tree requirement; however, the erection of the required 6 -foot masonry screening wall would kill the existing trees. The following solutions may be available, subject to negotiations with TP &L (Oncor), or variations of the following: • The installation of plant materials that, at mature height, would not interfere with the power lines and Item # 5 Page 3 of 5 the planting of the required 13 trees elsewhere on the site. • Work with Oncor to place the trees within the eastern portion of the easement as not to interfere with the power lines (this may not be feasible). • Seeking relief from the Board of Adjustment to grant a variance to the screening requirement given that the adjacent property is developed for a non - residential use, with the caveat that if the church property is redeveloped for residential use, the required screening wall can be built by this property owner. With this option, the nine existing trees (total of 72- caliper inches) would be preserved, which could fulfill the requirement of the 13, three - caliper inch trees. • Any combination of the above. It is the applicant's and staff's intent to resolve this issue prior to the Planning and Zoning Commission meeting on July 17th. Minor technical issues relating to this Site Plan are: the provision of specification as to the color of the metal gates on the dumpster, and verification that the brick color used for the screening wall match the color of the main building. Finally, the screening indicated along the northern property line adjacent to the day care is not required due to the fact that this property is also zoned for commercial uses. The applicant may eliminate this portion of the wall, if desired. The zoning classification on the property to the north needs to be corrected on the Site Plan to indicate C (Commercial) instead of MF -2 (Multi - family-2). RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: Staff recommends APPROVAL of the Site Plan for the Sandy Lake Plaza Medical Building, subject to the following conditions: 1) Resolution to the perimeter landscape and screening issues along the western property line. 2) Confirmation that brick used on the main building will also be used on the screening walls. 3) Specification of the color of the metal gates on the dumpster. 4) Correction of the zoning to the north of the property from MF -2 to C. Item # 5 Page 4 of 5 ALTERNATIVES 1) Recommend approval of the request 2) Recommend disapproval of the request 3) Recommend modification of the request 4) Take under advisement for reconsideration at a later date. ATTACHMENTS: 1) Site Plan 2) Exterior elevations (2 sheets) 3) Landscape Plan 4) Existing Tree and Mitigation Plan Item #i 5 Page 5 of 5 CITY OF COPPELL PLANNING DEPARTMENT STAFF REPORT CASE: SANDY LAKE PLAZA MEDICAL BUILDING LOT 1, BLOCK 1, MINOR PLAT P & Z HEARING DATE: July 17, 2003 C.C. HEARING DATE: August 12, 2003 STAFF REP.: Marcie Diamond, Assistant Planning Director LOCATION: At the northwest corner of Sandy Lake & Moore Roads SIZE OF AREA: Approximately 2.75 acres of property. CURRENT ZONING: C (Commercial) REQUEST: Minor Plat approval APPLICANT: The Cirrus Group 1700 Pacific Avenue, Suite 2730 Dallas, Texas 75201 (214) 953 -1722 FAX: (214) 953 -0278 Architect: John Garrison GSR Andrade Architects 4121 Commerce Street, Suite One Dallas, Texas 75226 (214) 824 -7040 FAX: (214) 887 -0559 Item #6 Engineer: Brandon O Donald Brockette. Davis. Drake 4144 N. Central Expry. Dallas, Texas 75204 (214) 824 -3647 FAX: (214) 824 -7064 Page 1 of 3 HISTORY: This area was preliminary platted as the Sandy Lake Plaza Addition. In the mid 1980's, the lot to the north of the subject tract was final platted as Lot 4 of this addition, and a Site Plan was approved for the Children's World day care center. In 1997, a request for a Special Use Permit for a Phillips 66 gas station, convenience store and car wash on 1.2 acres at the northwest corner of Sandy Lake and Moore Roads was recommended for denial by the Planning and Zoning Commission; this case was not appealed to City Council. In 1999, an application for Site Plan and Minor Plat approval for Sav -On Drugs was submitted on the subject property. The application was withdrawn prior to Planning and Zoning Commission consideration. TRANSPORTATION: Sandy Lake has recently been improved to a 4 -lane divided thoroughfare, built generally within 95 -feet of right -of -way. Moore Road is a 2 -lane undivided collector street, built within 60- feet of right -of -way. SURROUNDING LAND USE & ZONING: North -Day Care Center; C (Commercial) South - Single - family homes; SF -12 (Single Family -12) East - vacant and Austin Place residential subdivision; C (Commercial) and PD- 130 -SF -7 West - Sandy Lake Road Baptist Church; SF -12 (Single Family - 12) COMPREHENSIVE PLAN: The 1996 Comprehensive Master Plan shows the property as suitable for Neighborhood Retail. DISCUSSION: As discussed in the HISTORY portion of this report, a Preliminary Plat for this property was approved in the 1980's; however, a Final Plat for these tracts, which were envisioned as Lots 1, 2 and 3 of the Sandy Lake Plaza Addition was never submitted. Therefore, a Minor Plat is required to establish a building site for this medical facility. Item ##6 Page 2 of 3 This Minor Plat contains approximately 2.75 acres and provides for the required fire lane. A mutual access easement (existing shared driveway with the day care to the north) is also shown. The existing 15 -foot TP &L easement, which is discussed at length in the review of the Site Plan, is also depicted. Finally, the plat establishes a sidewalk and a water easement along Moore Road. The Engineering Department is requesting that a condition be included that additional easements may be necessary once final engineering is complete. Finally, Oncor is also requesting that the applicant /engineer discuss electric service requirements with them. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: Staff recommends APPROVAL of Sandy Lake Plaza Medical Addition, Lot 1, Block 1, Minor Plat, subject to the following condition: 1) Additional sidewalk and utility easements (City and franchise utility) may be required. ALTERNATIVES 1) Recommend approval of the request 2) Recommend disapproval of the request 3) Recommend modification of the request ATTACHMENTS: 1) Minor Plat Item #6 Page 3 of 3