Sherrill L2A-CS030314
Mar 14 03 01:26p Redi -Mix (940)898 -8684 p.3 CONCRETE CLIENT: CHOICE CONCRETE PROJECT: COPPELL PEDIATRIC ASSOCIATES, COPPELL February 28, 2003 MIX SPECIFICATIONS: MIX DESIGN NO. 721 APPLICATION: REQUIRED STRENGTH PLACEMENT SLUMP W/C RATIO AIR CONTENT MAXIMUM TEMPERATURE SOG 3000 PSI @ 28 DAYS 4 INCH +/- 1 0.55 LB/LB N/A 90 DEGREES F ASTM C94 STANDARD SPECIFICATIONS FOR READY -MIXED CONCRETE STATES AS FOLLOWS: "WHEN THE CONCRETE STRENGTH IS USED AS A BASIS FOR ACCEPTANCE, THE MANUFACTURER SHALL BE ENTITLED TO COPIES OF TEST REPORTS... THE INDIVIDUAL WHO SAMPLES AND TESTS CONCRETE MUST BE CERTIFIED ACI LEVEL 1. " ADDITIONAL WATER ADDED IN EXCESS OF SPECIFIED SLUMP IS AT CUSTOMERS RISK! GARY L. HERRON TECH. AL SERVICES DIRECTOR REDI -MIX, L.P. GENERAL OFFICE/1445 MacArthur Drive, Suite 136, Carrollton, Texas 75007 PHC)NE: (972) 242 -4550 CEMENT ASTM C150 TYPE 1/II 470 2.39 FLYASH ASTM C618 CLASS F 000 0.00 COARSE AGG. ASTM C33 SIZE NO. 57 1860 11.06 COARSE AGG. ASTM C33 SIZE NO. LIGHT WEIGHT ASTM C330 000 1545 9.42 FINE AGG. ASTM C33 FINE AGG. ASTM C33 ADMIXTURE ASTM C494 TYPE A or D 000 ADMIXTURE ASTM C494 TYPE F 00.0 0.00 ADMIXTURE ASTM C260 258 4.13 WATER 27.00 ASTM C94 STANDARD SPECIFICATIONS FOR READY -MIXED CONCRETE STATES AS FOLLOWS: "WHEN THE CONCRETE STRENGTH IS USED AS A BASIS FOR ACCEPTANCE, THE MANUFACTURER SHALL BE ENTITLED TO COPIES OF TEST REPORTS... THE INDIVIDUAL WHO SAMPLES AND TESTS CONCRETE MUST BE CERTIFIED ACI LEVEL 1. " ADDITIONAL WATER ADDED IN EXCESS OF SPECIFIED SLUMP IS AT CUSTOMERS RISK! GARY L. HERRON TECH. AL SERVICES DIRECTOR REDI -MIX, L.P. GENERAL OFFICE/1445 MacArthur Drive, Suite 136, Carrollton, Texas 75007 PHC)NE: (972) 242 -4550 Mar 14 03 01:26p Redi -Mix 19407898 -8684 p.4 REDI-MIX, INC. 1445 MacARTHUR DRIVE, SUITE 136 CARROLLTON, TX 75007 (972) 242 -4550 Frequency Distribution Analysis 28 Day Compressive Strength Mix: 721 Fla: 3000 psi 02/28/03 MIX DESCRIPTION 721 ---- - - - - -- 3000 psi ---- - - - - -- 02/28/02 Description 5 SACK Source MULTI -PLANT P. 1 Moving Avg: 3 Air Can 7 day 28 day 28 day Sample Slump Cant Tmp Comp Comp Comp ID in deg F psi psi psi 146539 5.25 > - 67 3900 4945 - 15500 5.50 > - 75 3780 5160 - 146017 4.25 - 80 3840 5195 5100 41613 5.00 - 86 3190 4030 4795 147928 5.25 > - 87 4260 4410 4545 24779 4.50 - 93 2000 3355 3932 12741679 4.50 - 75 3370 4095 3953 147767 5.50 > 2.0 75 3540 4030 3827 24079 4.75 - 92 2020 3070 3732 146013 5.50 > - 89 2700 3875 - - - - -- — ----- 3658 - - - - -- --------------------------------- 147500 4.00 - --- ---------------- 79 358C 4315 3753 148154 4.75 - 74 2280 3465 3885 147567 5.00 2.0 85 3830 4780 4187 806622 5.00 - 93 2300 3435 3893 148596 5.00 - 69 2930 4175 4130 141142 5.50 > - 88 3240 4045 3885 29860 5.00 - 87 3420 4415 4212 29918 5.25 > - 86 3350 4380 4280 32768 4.50 - 94 2800 3545 4113 20878 5.00 - 90 2050 - - 3020 -- 3648 21047 - ------------------------- 5.00 - 84 --- - - 2720 3875 3480 21096 5.25 > - 86 2860 3735 3543 21148 5.00 - 90 2650 3775 3795 820070 4.00 - 96 3070 3860 3790 147738 5.50 > - 69 2670 4055 3897 50673 4,50 - 73 2770 4715 4210 144836 4.00 - 60 3960 4935 4568 153296 5.00 - 80 3390 4295 4648 P. 1 Mar 14 03 01:26p Redi-Mix (940)898-8684 P.5 MD721 Frequency Distribution: 28 Day Compressive Strength Moving Avg: 3 Air Con 7 day 28 day 28 day Sample Slump Cont Tmp Comp Comp Comp ID in deg F psi psi psi 15893 5.50 > 65 3780 5195 4808 926090 4.50 so 3460 4635 4708 ----------------------------------------------------------------------- Co 30 2 30 30 30 28 Average---------------- ---------------------------------------------------- 4.91 2.0 81 3124 4161 4106 Standard Deviation --------------------------------------------------------- 0.47 11 627 606 429 Range 4.00 2.0 50 2000 3020 3480 5.50 > 2.0 96 4260 5195 5100 Coefficient of V ---------------------- ----------------------------- 9.60 13.60 20.06 14.57 10.46 P. 2 Mar 14 03 01:27p Redi -Mix (940)898 -8684 p.6 IT loon) 'Ilk CONCRETE CLIENT: CHOICE CONCRETE February 28, 2003 PROJECT: COPPELL PEDIATRIC ASSOCIATES, COPPELL MIX SPECIFICATIONS: APPLICATION: REQUIRED STRENGTH PLACEMENT SLUMP W/C RATIO AIR CONTENT MAXIMUM TEMPERATURE PARKING LOT PAVING 3000 PSI @ 28 DAYS 4 INCH +/- 1 0.53 LB /LB 5 +/- 1 90 DEGREES F MIX DESIGN NO. 723 MATERIALS ASTM STANDARDS WFIGHTS(SSD) VOLUME CEMENT ASTM C150 TYPE 1 /11 470 2.39 FLYASH ASTM C618 CLASS F 000 0.00 COARSE AGG. ASTM C33 SIZE NO. 67 1850 11.06 COARSE AGG. ASTM C33 SIZE NO. LIGHT WEIGHT ASTM C330 000 FINE AGG. ASTM C33 1344 8.19 FINE AGG. ASTM C33 ADMIXTURE ASTM C494 TYPE A or D 00.0 ADMIXTURE ASTM C494 TYPE F 00.0 ADMIXTURE ASTM C260 .25 — 4 oz/cwt 1.35 WATER 250 4.01 27.00 ASTM C94 STANDARD SPECIFICATIONS FOR READY -MIXED CONCRETE STATES AS FOLLOWS: "WHEN THE CONCRETE STRENGTH IS USED AS A BASIS FOR ACCEPTANCE, THE MANUFACTURER SHALL BE ENTITLED TO COPIES OF TEST REPORTS... THE INDIVIDUAL WHO SAMPLES AND TESTS CONCRETE MUST BE CERTIFIED ACI LEVEL L" ADDITIONAL WATER ADDED IN EXCESS OF SPECIFIED SLUMP IS AT CUSTOMERS RISK! 94 GARY L HERRON TECH AL SERVICES DIRECTOR REDI -MIX, L.P. GENERAL OFFICE/I445 MacArthur Drive, Suite 136, Carrollton, Texas 75007 PHONE: (972) 242 -4550 Mar 14 03 01:27p Redi -Mix (940)898 -8684 p.7 REDI -MIX, INC. 1445 MacARTHUR DRIVE, SUITE 136 CARROLLTON, TX 75007 (972) 242 -4550 P. 1 Frequency Distribution Analysis 28 Day Compressive Strength Mix: 723 F'c: 3000 psi 02/28/03 MIX DESCRIPTION 723 ----- ------ - - -- -- - - - -3000 psi - -- ---- - - - - -- 02/28/02 Description 5 SACK /AEA Source MULTI -PLANT Moving Avg: 3 Air Con 7 day 28 day 28 day Sample Slump Cont Tmp Comp Comp Comp ID in deg F psi psi psi 108796 4.00 4.0 77 3540 4750 - 136867 5.25 > 5.1 79 2960 3695 - 21695 5.25 > - 86 2260 3055 3833 127804 3.00 4.0 88 3220 3545 3432 28034 5.00 - 68 2990 3920 3507 28397 5.25 > 4.2 84 2570 3745 3737 29099 5.50 > 4.3 92 2570 3025 3563 20660 3.50 - 85 3100 4390 3720 21397 5.00 4.4 93 2790 3800 3738 35173 5.50 > 3.7 100 2670 - - -- -- 3510 - --------------- 3900 -- --------------------------------------------- 47569 5.50 > - 95 2700 4205 3838 35619 5.00 - 91 2830 4040 3918 49476 5.50 > 5.3 88 2540 4120 4122 38196 5.50 > 5.0 83 2590 3880 4013 35355 4.50 3.4 54 3930 5850 4617 35552 5.25 > 4.1 58 4150 5375 5035 36240 3.25 - 58 3200 4935 5387 36432 4.00 3.8 54 3780 4910 5073 36550 3.00 3.1 55 3220 5755 5200 36667 3.00 4.2 52 4010 5465 5377 ----------------------------------------------------------------------- 45932 5.00 4.2 62 2670 3870 5030 145371 5.00 4.6 55 3240 3805 4380 55695 4.75 3.7 56 3160 4260 3978 55704 5.00 3.9 54 3120 3995 4020 55713 4.50 3.9 57 3240 4330 4195 55725 4.75 3.4 56 3610 4515 4280 56119 5.00 3.6 67 3190 4620 4488 146093 5.50 > 4.5 64 3340 3745 4293 P. 1 Mar 14 03 01:27p Redi -Mix (940)898 -8684 p.8 X723 Frequency Distribution: 28 Day Compressive Strength Moving Avg: 3 Air Can 7 day 26 day 28 day Sample Slump Cant Tmp Comp Comp Comp ID in deg F psi psi psi. 146100 5.00 4.4 64 3000 3835 4067 14610493 ----------------------------------------------- 5.00 4.6 64 3280 - -- -- 4110 _------ 3 897_ - Count ------------------------ 30 24 30 30 -- Average ------------------------------ 4.71 4.1 72 ----------------------------- 3117 4235 42 - - -- Standard Deviation --------- --`- - - - - -` ----------------------- 466 ------- 716 5 78 0.81 0.5 16 ------- - -- Range 3.00 3.1 52 2260 - 3025 3432 5.50 > 5.3 100 4150 5850 5387 Coefficient of Variation ------- 17.25 13.16 - -- -"- 22.17 ------------------------------------- 14.94 16.90 13.63 P. 2 Mar 14 03 01:27p Redi -Mix (940)898 -8684 p.9 is a�i a `?f+ li , CONCRETE CLIENT: CHOICE CONCRETE February 28, 2003 PROJECT: COPPELL PEDIATRIC ASSOCIATES, COPPELL MIX SPECIFICATIONS APPLICATION: REQUIRED STRENGTH PLACEMENT SLUMP WIC RATIO AIR CONTENT MAXIMUM TEMPERATURE MIX DESIGN NO. 732 CITY APPROACH & FIRE LANES 360OPSI C 28 DAYS 3 INCH 4/- 1 0.45 LB /LB 5+1_1 % 95 DEGREES F MATERIAL ASTM STANDARDS WEIGHTS( V OLUME CEMENT ASTM C150 TYPE 1 /II 564 2.87 FLYASH ASTM C618 CLASS F 000 0.00 COARSE AGG. ASTM C33 SIZE NO. 57 1858 11.11 COARSE AGG. ASTM C33 SIZE NO. LIGHT WEIGHT ASTM C330 000 FINE AGG. ASTM C33 1247 7.60 FINE AGG. ASTM C33 ADMIXTURE ASTM C494 TYPE A or D 3 - 6 oz/cwt ADMIXTURE ASTM C494 TYPE F 00.0 1.35 ADMIXTURE ASTM C260 .2 - 4 oz/cwt 254 4.07 WATER 27.00 ASTM C94 STANDARD SPECIFICATIONS FOR READY -MIXED CONCRETE STATES AS FOLLOWS: "WHEN THE CONCRETE STRENGTH IS USED AS A BASIS FOR ACCEPTANCE THE MANUFACTURER SHALL BE ENTITLED TO COPIES OF TEST REPORTS... THE INDIVIDUAL WHO SAMPLES AND TESTS CONCRETE MUST BE CERTIFIED ACI LEVEL I. " ADDITIONAL WATER ADDED IN EXCESS OF SPECIFIED SLUMP IS AT CUSTOMERS RISK'. GARY .HERRON TECHN AL SERVICES DIRECTOR REDI -MIX, L.P. GENERAL OFFICE/1445 MacArthur Drive, Suite 136, Carrollton. Texas 75007 PHONE: (972) 242 -4550 Mar 14 03 01:28p Redi -Mix (940)898 -8684 p.10 REDI -MIX, INC. 1445 MacARTHUR DRIVE, SUITE 136 CARROLLTON, TX 75007 (972) 242 -4550 Frequency Distribution Analysis 28 Day Compressive Strength Mix: 732 F'c: 4000 psi 02/28/03 MIX DESCRIPTION 732 ---- - - - - -- 4000 psi ---- - - - - -- 02/28/02 Description 6 SACK -WRA /AEA Source MULTI - PLANT P. 1 Moving Avg: 3 Air Con 7 day 28 day 28 day Sample Slump Cont Tmp Comp Comp Comp ID in deg F psi psi psi 20250 4.25 --------------- - 70 -_- 4580 6200 - 100064 4.50 6.0 73 4445 5700 - 100311 4.50 6.1 > 58 4280 5540 5813 331918 4.00 - - 4245 5253 5498 13505 4.00 - 82 3184 4422 5072 100561 3.50 5.2 64 4370 5940 5205 19813 4.50 4.5 101 > 3515 4845 5069 19785014 4.25 4.3 104 > 3405 4575 5120 29591 4.25 - 80 3865 4875 4765 20438 3.75 5.0 64 3270 4385 4612 ----------------------------------------------------------------------- 20456 4.00 4.9 71 3125 4040 4433 139 4.50 - 80 3890 4860 4428 56678 4.50 3.6 74 4374 5845 4915 14579 4.50 - 78 3645 4795 5167 20060 3.75 - 72 3825 5465 5368 58432 4.50 - 90 4220 5205 5155 58726 4.00 - 91 3420 5230 5300 4193 3.50 3.1 70 4564 5532 5322 121472 4.25 4.2 71 3395 4335 5032 48071 4.50 - 90 4910 5515 5127 ------ - - -- 48486 -- ---------------------------------------------------------- 4.00 4.5 92 3900 4895 4915 17564 3.50 6.8 > 89 4250 5195 5202 587 4.25 2.0 < 100 4080 5185 5092 49328 3.50 4.8 86 4620 5855 5412 40078 4.50 3.8 89 3620 4535 5192 106164 4.00 4.1 91 5100 5725 5372 40871 4.00 4.0 89 3860 4840 5033 30654 4.50 - 8B 4110 5105 5223 P. 1 Mar 14 03 O1:28p Redi -Mix 19401898 -8684 p.11 MD732 Frequency Distribution: 28 Day Compressive Strength 83 3840 4395 4780 Moving 3.50 - 74 Avg: 3 Air Con 7 day 28 day 28 day Sample Slump Cont Tmp Comp Comp Comp ID in deg F psi psi psi 25671 4.50 5.6 83 3840 4395 4780 100353 3.50 - 74 3770 5955 5152 Count-------------------------- -------------------------------------------- 30 18 29 30 30 28 Average------------- ------------- - - - - -- ----------------------------- 4.13 4.6 82 3989 5141 5099 Standard Deviation --------------------------------------------------------- 0.37 1.1 12 509 568 303 Range------------------- - ----- --------------------------------------------- 3.50 2.0 < 58 3125 4040 4428 4.50 6.8 > 104 > 5100 6200 5813 Coefficient of Variation --------------------------------------------------- 8.97 24.95 14.36 12.76 11.06 5.95 u P. 2 Mar 14 03 01:28p Redi -Mix [940]898 -8884 p.12 r�i •11 CONCRETE PUMPING NOTES & RECOMMENDATIONS • 5" minimum diameter lines with no reduction to smaller tines • Rubber hoses should be kept to a minimum with as few 90- degree angles as possible. • It is recommended that tests for slump and strength should be taken at discharge end of bole. • Equivalent strength grout should be used to prime pump lines if grout is to remain in placement. • Mix designs are based on cement requirements pumped from ground level. Additional cement may be required (at contractors expense) as pump lines increase or configurations change. • Excessive loss of entrained air may result from boom configuration or free fall discharge. To ensure minimum loss of entrained air when pumping maintain a continuous flow of concrete and do not subject to free -fall. Enclosed for your review is all available back up data for the proposed mix design(s). If strength data is not available or insufficient, confirmation tests may have to be conducted by your laboratory. Unless this office is notified otherwise we will assume concrete mix designs have been approved as submitted. Unless otherwise noted REDI -MIX, LP will guarantee the strength performance of mix design(s) submitted up to a maximum placement temperature of 100 degrees (F) provided an ASTM C494 Type D water reducer is utilized and concrete is placed within 75 minutes from time hatched. Test ready mixed concrete in accordance with all applicable standards set forth in ASTM C94. REDI -MIX, L.P. GENERAL OFFICEl1445 MacArthur [)rive, SJite 136, Carrollton, Texas 75007 PHONE: (972) 242 -4550