Loading...
Sherrill L2A-LR030313A ALPHA TESTING, INC. REPORT OF FIELD COMPACTION TESTS 2209 Wisconsin St., Suite 100 Dollos, Texas 75229 9721620 -8911 - 9721263 -4937 (Metro) FAX. 9721406 -8023 TESTED FOR TRI -STAR CONSTRUCTION LEW ISVILLE, TEXAS DATE: 03/13/03 PROJECT COPPELL PEDIATRIC CLINIC COPPELL, TEXAS TEST t1ATA- OUR REPORT NO.: 03153 -13 TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT' 15 03/13/03 FG -2.5 6 14.0 115 13.1 112 97 1 -AD 16 03/13/03 FG -2.5 6 14.0 115 12.5 113 98 1 -AD 17 03/13/03 FG -2.0 6 14.0 115 1 13.0 110 95 1 -AD 18 03/13/03 FG -2.0 6 14.0 115 12.0 110 96 1 -AD 19 03/13/03 FG -1.5 6 1 14.0 115 13.0 112 97 1 -AD 20 03/13/03 FG -1.5 6 14.0 1 115 12.1 112 98 1 -AD 21 03/13/03 FG -1.0 6 14.0 115 14.7 112 98 1 -AD TCCT 1 nr ATIr1Al- 15 RETEST OF TEST #3 PERFORMED ON 03/06/03 16 RETEST OF TEST #4 PERFORMED ON 03106/03 17 RETEST OF TEST #5 PERFORMED ON 03/06/03 18 RETEST OF TEST #6 PERFORMED ON 03/06/03 19 RETEST OF TEST #7 PERFORMED ON 03/07/03 20 RETEST OF TEST #8 PERFORMED ON 03107/03 21 RETEST OF TEST #9 PERFORMED ON 03/07/03 CC: CITY OF COPPELL 1. FILL ' A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS Re p tfully 5W� 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D. RETEST ALPHA TIN Our test results & reports are for the exclusive use of the Client land their designated recipients on file in our office) and shall not be reproduced and/or distributed -t4o with express approval of ALPHA. The use of our name & test results must receive ourwdtten approval. Test results & reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Geotechnical Engineering 2' Construction Materials Testing fh Environmental Engineering Rj Consulting A ALPHA TESTING, INC. REPORT OF FIELD COMPACTION TESTS 2209 Wisconsin St., Suite 100 Dollos, Texas 75229 9721620 -8911 - 9721263 -4937 (Metro) FAX: 9721406 -8023 TESTED FOR TRI -STAR CONSTRUCTION LEWISVILLE, TEXAS DATE: 03/13/03 PROJECT COPPELL PEDIATRIC CLINIC COPPELL, TEXAS TCCT MATH. OUR REPORT NO.: 03153 -13A TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT' 22 03/13/03 FG -1.0 6 14.0 115 14.4 114 99 1 -AD 23 03/13/03 FG -0.5 6 14.0 115 14.2 110 96 1 -AD 24 03/13/03 FIG 6 14.0 115 15.0 112 97 1 -AD 25 03/13/03 FIG 6 14.0 115 15.3 110 95 1 -AD .'l k1 I CJ I lmm 22 , I 1 1Y. RETEST OF TEST #10 PERFORMED ON 03/07/03 23 RETEST OF TEST #11 PERFORMED ON 03/07/03 24 RETEST OF TEST #13 PERFORMED ON 03/07/03 25 RETEST OF TEST #14 PERFORMED ON 03/07/03 CC: CITY OF COPPELL 1. FILL ' A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS Res tfully S 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4, CEMENT TREATED D. RETEST Our test results & reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distnbule cQptroFth @Kpiiels approval of ALPHA. The use of our name & lest results must receive our written approval. Test results B reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Geotechnical Engineering Ri Construction Materials Testing P Environmental Engineering /2) Consulting