Freeport NIP(7.0)-LR030722RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project: Freeport 10
500 Freeport Parkway
Coppell, TX
Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
CONTRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT: On site
SPECIFICATION REQUIREMENTS
STRENGTH:
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
1
1 3.5
1 2 3.5
1 3 3.5
1 4
4000 psi 28 Days
5" maximum
3 -6%
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
MEASURED
SLUMP
(inches)
CONCRETE COMPRESSIVE STRENGTH TEST
PROJECT DATA
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 06/23/2003
WEATHER CONDITIONS: Sunny
TIME SAMPLED: 7: loam BATCH TIME: 6:46am
TEMPERATURE (F) AIR 85 F CONCRETE: 83 F
TRUCK NO: 104 TICKET NO: 116001
AIR CONTENT 2.2 UNIT WEIGHT (pet): NA
OVERALL PLACEMENT LOCATION:
Paving southeast firelane, approach, south half of south parking lot between building
column lines 5 to DD
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
DATE
TESTED
06/30/2003
07/21/2003
07/21/2003
Hold
SAMPLE LOCATION: 6 east by 2' south from northwest
corner of approach
AGE
(days)
7
28
28
MAXIMUM
LOAD
(Ibs. force)
127340
149685
146195
Average
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
Report No.:
Project No.:
Date of Service:
Report Date:
COMPRESSIVE
STRENGTH
(psi)
4500
5290
5170
5230
179038
037333
06/23/2003
07/22/2003
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01DD Page 1 of 7
RoneEngineers
to
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
CONTRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT: On site
SPECIFICATION REQUIREMENTS
STRENGTH:
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
2 4
4000 psi 28 Days
5" maximum
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
MEASURED
SLUMP
(inches)
2 1 4.0
2 2 4.0
2 3 4.0
DATE
TESTED
06/30/2003
07/21/2003
07/21/2003
Hold
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Report No.:
Project No.:
Date of Service:
Report Date:
179038
037333
06/23/2003
07/22/2003
Project: Freeport 10
500 Freeport Parkway
Coppell, TX
Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 06/23/2003
WEATHER CONDITIONS: Sunny
TIME SAMPLED: 8:15am BATCH TIME. 7
TEMPERATURE (F) AIR 88 F CONCRETE: 85 F
TRUCK NO: 104 TICKET NO: 116011
3% 6% AIR CONTENT 1.9 UNIT WEIGHT (per): NA
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
OVERALL PLACEMENT LOCATION:
Paving southeast firelane, approach, south half of south parking lot between building
column lines 5 to DD
SAMPLE LOCATION: 45' east by 3' south from northeast
comer of approach
AGE
(days)
7
28
28
MAXIMUM
LOAD
(lbs. force)
123275
142905
137410
Average
COMPRESSIVE
STRENGTH
(psi)
4360
5050
4860
4960
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01DD Page 2 of 7
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project: Freeport 10
500 Freeport Parkway
Coppell, TX
Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
CONTRACTOR:
CONCRETE SUPPLIER:
PLANT:
Duke Realty Services, LP
Potter
On site
SPECIFICATION REQUIREMENTS
STRENGTH: 4000 psi 28 Days
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
3 4
5" maximum
3 %a -6%
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
MEASURED
SLUMP
(inches)
3 1 4.25
3 2 4.25
3 3 4.25
DATE
TESTED
06/30/2003
07/21/2003
07/21/2003
Hold
CONCRETE COMPRESSIVE STRENGTH TEST
PROJECT DATA
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
AGE
(days)
7
28
28
MAXIMUM
LOAD
(lbs. force)
104475
123055
126560
Average
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
Report No.:
Project No.:
Date of Service:
Report Date:
SAMPLE LOCATION: 110' east by 4' south from
northwest corner of approach
COMPRESSIVE
STRENGTH
(Psi)
3690
4350
4480
4420
179038
037333
06/23/2003
07/22/2003
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 06/23/2003
WEATHER CONDITIONS: Sunny
TIME SAMPLED: 9:50am BATCH TIME: 9:28am
TEMPERATURE (F) AIR 92 F CONCRETE: 88 F
TRUCK NO: 104 TICKET NO: 116021
AIR CONTENT 4.5 UNIT WEIGHT (pcf): NA
OVERALL PLACEMENT LOCATION:
Paving southeast firelane, approach, south half of south parking lot between building
column lines 5 to DD
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Roue Engineers, Ltd.
01DD Page 3 of 7
RoneEngineers
1
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project: Freeport 10
500 Freeport Parkway
Coppell, TX
Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
CONTRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT: On site
SPECIFICATION REQUIREMENTS
STRENGTH:
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
4 4
4000 psi 28 Days
5" maximum
3% -6%
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
MEASURED
SLUMP
(inches)
4 1 4.75
4 2 4.75
4 3 4.75
DATE
TESTED
06/30/2003
07/21/2003
07/21/2003
Hold
CONCRETE COMPRESSIVE STRENGTH TEST
PROJECT DATA
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
Report No.:
Project No.:
Date of Service:
Report Date:
179038
037333
06/23/2003
07/22/2003
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 06/23/2003
WEATHER CONDITIONS: Sunny, party cloudy
TIME SAMPLED: 11:OSam BATCH TIME: 10:45am
TEMPERATURE (F) AIR 91 F CONCRETE: 88 F
TRUCK NO: 104 TICKET NO: 116031
AIR CONTENT 3.9 UNIT WEIGHT (pcf): NA
OVERALL PLACEMENT LOCATION:
Paving southeast firelane, approach, south half of south parking lot between building
column lines 5 to DD
SAMPLE LOCATION: 35' west by 4' south from northeast
corner of approach
AGE
(days)
7
28
28
MAXIMUM
LOAD
(lbs. force)
95400
117730
118298
Average
COMPRESSIVE
STRENGTH
(Psi)
3370
4160
4180
4170
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01DD Page 4 of 7
RoneEngineers
to
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project:
Services:
CONTRACTOR:
CONCRETE SUPPLIER:
PLANT:
SPECIFICATION REQUIREMENTS
STRENGTH:
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
5 1
5 2
5 3
5 4
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement Locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Duke Realty Services, LP
Potter
On site
4000 psi 28 Days
5" maximum
3 -6 %a
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
MEASURED
SLUMP
(inches)
4.25
4.25
4.25
DATE
TESTED
06/30/2003
07/21/2003
07/21/2003
Hold
CONCRETE COMPRESSIVE STRENGTH TEST
PROJECT DATA
Report No.:
Project No.:
Date of Service:
Report Date:
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 06/23/2003
WEATHER cONnrrIONS: Sunny, partly cloudy
TIME SAMPLED: 12:45pm BATCH TIME: 12:23pm
TEMPERATURE (F) AIR 92 F CONCRETE: 87 F
TRUCK NO: 106 TICKET NO: 1 16041
AIR CONTENT 4.8 UNIT WEIGHT (pcf): NA
OVERALL PLACEMENT LOCATION:
Paving southeast firelane, approach, south half of south parking lot between building
column lines 5 to DD
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
SAMPLE LOCATION: 25' west by 20' south from
northwest comer of parking lot
AGE
(days)
7
28
28
MAXIMUM
LOAD
(lbs. force)
110785
134930
135505
Average
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
COMPRESSIVE
STRENGTH
(Psi)
3920
4770
4790
4780
179038
037333
06/23/2003
07/22/2003
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
O1DD Page 5 of 7
RoneEngineers
N
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project:
Services:
CONTRACTOR:
CONCRETE SUPPLIER:
PLANT:
STRENGTH:
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
6 1
6 2
6 3
6 4
CONCRETE COMPRESSIVE STRENGTH TEST
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
SPECIFICATION REQUIREMENTS
Duke Realty Services, LP
Potter
On site
4000 psi 28 Days
5" maximum
3 -6%
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
MEASURED
SLUMP
(inches)
4.25
4.25
4.25
DATE
TESTED
06/30/2003
07/21/2003
07/21/2003
Hold
PROJECT DATA
Report No.:
Project No.:
Date of Service:
Report Date:
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 06/23/2003
WEATHER CONDITIONS: Sunny
TIME SAMPLED: 1:45pm BATCH TIME: 1:28pm
TEMPERATURE (F) AIR 91 F CONCRETE: 88 F
TRUCK NO: 1 13 TICKET NO: 116051
AIR CONTENT 4.0 UNIT WEIGHT (pcf): NA
OVERALL PLACEMENT LOCATION:
Paving southeast firelane, approach, south half of south parking lot between building
column lines 5 to DD
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
SAMPLE LOCATION: 150' west by 15' south from
northwest corner of parking lot
AGE
(days)
7
28
28
MAXIMUM
LOAD
(lbs. force)
119455
137410
146090
Average
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
COMPRESSIVE
STRENGTH
(p
4220
4860
5170
5020
179038
037333
06/23/2003
07/22/2003
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
O1DD Page 6 of 7
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project:
Services:
CONTRACTOR:
CONCRETE SUPPLIER.
PLANT:
SPECIFICATION REQUIREMENTS
STRENGTH:
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
MEASURED
SLUMP
(inches)
7 1 3.75
7 2 3.75
7 3 3.75
7 4
Technician: Jeremy Watts
Report Distribution:
(1) Duke Realty Services, LP
(1) Duke Realty Services, LP
(1) City of Coppell Engineering Dept.
(1) Potter Concrete
Duke Realty Services, LP
Potter
On site
4000 psi 28 Days
5" maximum
3 -6%
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
DATE
TESTED
06/30/2003
07/21/2003
07/21/2003
Hold
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
CONCRETE COMPRESSIVE STRENGTH TEST
Started: 6:30am
PROJECT DATA
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
AGE
(days)
7
28
28
(1) Pacheco Koch Consulting Engineers
(1) Engineering Analyst
(1) City of Coppell Bldg. Inspections
Finished: 4:30pm
MAXIMUM
LOAD
(Ibs. force)
123345
119570
Average
Report No.:
Project No.:
Date of Service:
Report Date:
SAMPLE LOCATION: 25' east by 15' south from
northwest comer of parking lot
COMPRESSIVE
STRENGTH
(psi)
97675 3450
4360
4230
4300
179038
037333
06/23/2003
07/22/2003
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 06/23/2003
WEATHER CONDITIONS: Sunny
TIME SAMPLED: 3:O5pm BATCH TIME: 2.27pm
TEMPERATURE (F) AIR 95 F CONCRETE: 89 F
TRUCK NO: 1 TICKET NO: 1 16061
AIR CONTENT 4.3 UNIT WEIGHT (pcf): NA
OVERALL PLACEMENT LOCATION:
Paving southeast firelane, approach, south half of south parking lot between building
column lines 5 to DD
K. Scott Watson,
CMT Operations Manager
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
OIDD Page 7 of 7